API RP 14F:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS
Hardcopy , PDF
02-17-2021
English
01-01-2013
1 General
1.1 Scope
1.2 Applicability of National Electrical Code
2 References
2.1 Industry Codes, Guides, and Standards
2.2 Government Codes, Rules, and Regulations
2.3 Classification Society Rules and Regulations
3 Acronyms and Abbreviated Definitions
3.1 Acronyms
3.2 Definitions, Abbreviated
3.3 Definitions Specific to Floating Facilities
4 Electrical Equipment for Hazardous (Classified) Locations
4.1 General
4.2 High-temperature Devices
4.3 Protection Techniques Related To Equipment Installed in
Locations Classified as Division 1 or Division 2
4.4 Protection Techniques Related to Equipment Approved for
Zone 0, Zone 1, or Zone 2 Locations
4.5 General Purpose Equipment
4.6 Listing, Marking and Documentation
5 Electric Power Generating Stations
5.1 General
5.2 Prime Movers
5.3 Generators
5.4 Generator Packaging Considerations
5.5 Switchboards
5.6 Special Requirements for Floating Facilities
6 Electrical Distribution Systems
6.1 Scope
6.2 Voltage Level Selection
6.3 Conductor Selection
6.4 Wiring Methods for Classified Locations
6.5 Wiring Methods for Unclassified Locations
6.6 Wiring Methods for Drilling and Workover Rigs
6.7 General Wiring Considerations
6.8 Conduit and Cable Seals and Sealing Methods
6.9 Circuit Protection
6.10 Grounding
6.11 Electrical Enclosures
6.12 Working Space About Electrical Equipment and Means of
Access
6.13 Additional Requirements for Floating Facilities
7 Electric Motors
7.1 General
7.2 Selection
7.3 Motor Space Heaters
7.4 Motor Control
8 Transformers
8.1 General
8.2 Selection
8.3 Installation
8.4 Connections
8.5 Protection
9 Lighting
9.1 General
9.2 Lighting Levels
9.3 Fixture Selection and Installation
9.4 Standby Lighting
9.5 Lighting for Helicopter Operations
10 Battery-powered DC Supply Systems
10.1 General
10.2 Specific Applications
10.3 Batteries
10.4 Battery Chargers
10.5 Uninterruptible Power Supply (UPS) Systems
11 Special Systems
11.1 Electrical Platform Safety Control Systems
11.2 Gas Detection Systems
11.3 Fire Detection Systems
11.4 Aids-to-Navigation Equipment
11.5 Communications Equipment
11.6 Heat Trace Systems
11.7 Fire Pumps
11.8 Adjustable Frequency Controllers (Variable Frequency
Drives)
11.9 Submarine Cables
11.10 Electric Oil-immersion Heaters
11.11 Electric Power-operated Boat Winches for Survival Craft
11.12 Electric Power-operated Water-tight Doors
11.13 Hull Mechanical Systems Controls
11.14 Cargo Tanks on Floating Facilities
11.15 Cargo Handling Rooms on Floating Facilities
11.16 General Alarm System
11.17 Cathodic Protection
12 Special Considerations
12.1 Construction Practices
12.2 Electronic Instrumentation
12.3 Electrical Tools
12.4 Electrical Appliances
12.5 Extension Cords
12.6 Electrical Equipment Buildings
12.7 Signs
12.8 Lockout and Tagout Procedures
12.9 Portable Electronic Devices
13 System Checkout
13.1 General
13.2 Generators and Motors
13.3 Instrumentation and Control Circuits
14 Maintenance
15 Safety
Annex A (informative) - Inspection Intervals
Annex B (informative) - ABS Rules For Building and Classing Steel
Vessels - 1998, PART 4
Annex C (informative) - USCG Requirements, 46 CFR, Subchapter J,
111.95
Annex D (informative) - USCG Requirements, 46 CFR, Subchapter J,
111.97
Annex E (informative) - USCG Requirements, 46 CFR, Subchapter J,
Subpart 111.105
Describes minimum requirements and guidelines for the design, installation, and maintenance of electrical systems on fixed and floating petroleum facilities located offshore.
DocumentType |
Standard
|
Pages |
164
|
ProductNote |
Reconfirmed 2008
|
PublisherName |
American Petroleum Institute
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEEE C37.12-2008 | SPECIFICATION GUIDE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS BASED ON A SYMMETRICAL CURRENT BASIS |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
CFR 33(PTS125-199) : JUL 2017 | NAVIGATION AND NAVIGABLE WATERS |
ISA 60079-7 : 2008 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E" |
IEEE C37.14-2015 | IEEE Standard for DC (3200 V and below) Power Circuit Breakers Used in Enclosures |
IEEE C37.20.1-2015 | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
IEEE 1202-2006 | IEEE Standard for Flame-Propagation Testing of Wire & Cable |
CFR 46(PTS90-139) : OCT 2017 | SHIPPING - COAST GUARD, DEPARTMENT OF TRANSPORTATION |
CSA C22.2 No. 157 : 1992 | INTRINSICALLY SAFE AND NON-INCENDIVE EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS |
API 500 : 2012 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
ISA 60079-5 : 1998 | EXPLOSIVE ATMOSPHERES - PART 5: EQUIPMENT PROTECTION BY POWDER FILLING 'Q' |
ISA 12.01.01 : 2009 | DEFINITIONS AND INFORMATION PERTAINING TO ELECTRICAL EQUIPMENT IN HAZARDOUS (CLASSIFIED) LOCATIONS |
UL 514A:11ED 2013-02-01 | Metallic Outlet Boxes |
API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
NEMA MG 1 : 2016 | MOTORS AND GENERATORS |
UL 50:13ED 2015-10-16 | Enclosures for Electrical Equipment, Non-Environmental Considerations |
NEMA MG 2:2014 | Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators |
UL 1072:4ED 2006-06-30 | Medium-Voltage Power Cables |
NEMA MG 10:2017 | Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors |
API RP 14C : 2017 | ANALYSIS, DESIGN, INSTALLATION, AND TESTING OF SAFETY SYSTEMS FOR OFFSHORE PRODUCTION FACILITIES |
ISA 12.12.01 : 2007 | NONINCENDIVE ELECTRICAL EQUIPMENT FOR USE IN CLASS 1 AND 2, DIVISION 2 AND CLASS 3, DIVISIONS 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS |
ISA TR12.24.01 : 1998 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS CLASSIFIED AS CLASS 1, ZONE 0, ZONE 1, OR ZONE 2 |
ISA RP92.0.02-2 : 1998 | INSTALLATION, OPERATION, AND MAINTENANCE OF TOXIC GAS-DETECTION INSTRUMENTS: HYDROGEN SULFIDE |
API 546 : 2008 | BRUSHLESS SYNCHRONOUS MACHINES - 500 KVA AND LARGER |
IEEE 841-2009 | IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp) |
NFPA 325 : 1994 | FIRE HAZARD PROPERTIES OF FLAMMABLE LIQUIDS, GASES, AND VOLATILE SOLIDS |
NFPA 101 : 2018 | LIFE SAFETY CODE |
IES HB 9 : 2000 ERRATA 2006 | IESNA LIGHTING HANDBOOK |
ISA 92.0.01-1 : 1998 | PERFORMANCE REQUIREMENTS FOR TOXIC GAS-DETECTION INSTRUMENTS: HYDROGEN SULFIDE |
IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
NFPA 70B : 2016 | RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE |
IEEE/ANSI Y32.9-1972 | American National Standard Graphic Symbols for Electrical Wiring and Layout Diagrams Used in Architecture and Building Construction |
NEMA 250 : 2014 | ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM) |
NEMA ICS 6-1993 (R2006) | Industrial Control and Systems: Enclosures |
UL 83:16ED 2017-07-28 | Standard for Thermoplastic-Insulated Wires and Cables |
NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
NFPA 69 : 2014 | EXPLOSION PREVENTION SYSTEMS |
NEMA ICS 2.1 : 1990 | |
API 2003 : 2015 | PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, LIGHTNING, AND STRAY CURRENTS |
ISA 60079-1 : 2005 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D" |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
NACE RP 01 76 : 2003 | CORROSION CONTROL OF STEEL FIXED OFFSHORE STRUCTURES ASSOCIATED WITH PETROLEUM PRODUCTION |
WC 5-1992 | THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
CFR 49(PTS186-199) : 0 | TRANSPORTATION |
WC 8:1988 | ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
ICEA P 32 382 : 2007(R2018) | SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
ISA 60079-18 : 2005 | EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION "M" |
UL 514C:4ED 2014-04-08 | Nonmetallic Outlet Boxes, Flush-Device Boxes, and Covers |
IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
NFPA ELEC INSTALLATIONS IN HAZ LOCATIONS : 2008 | ELECTRICAL INSTALLATIONS IN HAZARDOUS LOCATIONS |
NEMA FG 1:1993 | FIBERGLASS CABLE TRAY SYSTEMS |
IEEE 835-1994 | IEEE Standard Power Cable Ampacity Tables |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
ISA 60079-11 : 2002 | EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I' |
IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) |
ISA 60079-6 : 1998 | EXPLOSIVE ATMOSPHERES - PART 6: EQUIPMENT PROTECTION BY OIL-IMMERSION 'O' |
UL 1309:3ED 2017-04-21 | Marine Shipboard Cable |
IEEE C37.010-1999 | IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
NEMA VE 1:2017 | Metal Cable Tray Systems |
IEEE C37.13-2015 | IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures |
ISA 12.13.01 : 2003 | PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS |
ANSI C84.1 : 2016 | ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ) |
ASTM D 4066 : 2013 | Standard Classification System for Nylon Injection and Extrusion Materials (PA) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISA TR12.21.01 : 2004 | USE OF FIBER OPTIC SYSTEMS IN CLASS 1 HAZARDOUS (CLASSIFIED) LOCATIONS |
NFPA 70E : 2018 | ELECTRICAL SAFETY IN THE WORKPLACE |
API 505 : 1997 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2 |
IEEE 484-2002 | IEEE Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications |
NFPA 99 : 2018 | HEALTH CARE FACILITIES CODE |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
WC 3-1992 | RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
IEEE 1100 : 2005 | POWERING AND GROUNDING ELECTRONIC EQUIPMENT |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
FAA AC 70-7460-1 : 2015 | OBSTRUCTION MARKING AND LIGHTING |
IEEE 450-2010 REDLINE | IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications |
CFR 33(PTS1-124) : JUL 2017 | NAVIGATION AND NAVIGABLE WATERS |
NEMA ICS 2.4 : 2003(R2012) | INDUSTRIAL CONTROL AND SYSTEMS: NEMA AND IEC DEVICES FOR MOTOR SERVICE - A GUIDE FOR UNDERSTANDING THE DIFFERENCES |
IES RP 1 : 2004 | PRACTICE FOR OFFICE LIGHTING |
NEMA ICS 1 : 2000(R2015) | INDUSTRIAL CONTROL AND SYSTEMS: GENERAL REQUIREMENTS |
ISA 12.27.01 : 2003 | REQUIREMENTS FOR PROCESS SEALING BETWEEN ELECTRICAL SYSTEMS AND FLAMMABLE OR COMBUSTIBLE PROCESS FLUIDS |
ISA 12.20.01 : 2009(R2014) | GENERAL REQUIREMENTS FOR ELECTRICAL IGNITION SYSTEMS FOR INTERNAL COMBUSTION ENGINES IN CLASS 1, DIVISION 2 OR ZONE 2, HAZARDOUS (CLASSIFIED) LOCATIONS |
API STD 541 : 2014 | FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER |
IP 15 : 2015 | PETROLEUM PRODUCTS - DETERMINATION OF POUR POINT |
IEEE C37.27-2008 REDLINE | IEEE Application Guide for Low-Voltage AC Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
ISA RP12.13.02 : 2003 | INSTALLATION, OPERATION, AND MAINTENANCE OF COMBUSTIBLE GAS DETECTION INSTRUMENTS |
UL 13:4ED 2015-03-18 | Power-Limited Circuit Cables |
NFPA 77 : 2014 | STATIC ELECTRICITY |
UL 783:6ED 2003-04-28 | Electric Flashlights and Lanterns for Use in Hazardous (Classified) Locations |
UL 2250:3ED 2017-03-30 | Instrumentation Tray Cable |
IEEE C57.12.70-2011 | IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers |
CFR 29(PT1926) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR - SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
CFR 30(PTS200-699) : JUL 2017 | MINERAL RESOURCES - DEPARTMENT OF THE INTERIOR |
API 14G : 2007 | RECOMMENDED PRACTICE FOR FIRE PREVENTION AND CONTROL ON FIXED OPEN-TYPE OFFSHORE PRODUCTION PLATFORMS |
NFPA 37 : 2018 | INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
NEMA ICS 2.3 : 1995(R2008) | INDUSTRIAL CONTROL AND SYSTEMS: INSTRUCTIONS FOR THE HANDLING, INSTALLATION, OPERATION AND MAINTENANCE OF MOTOR CONTROL CENTERS |
ISA 12.10.05 : 2004 | ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - CLASSIFICATION OF ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS |
ISA 12.04.01 : 2003 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 2: PRESSURIZED ENCLOSURES "P" |
IEEE 1242-1999 | IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants |
NFPA 78 : 1989 | LIGHTNING PROTECTION CODE |
IEC 60331:1970 | Fire-resisting characteristics of electric cables |
IEEE 515-2011 | IEEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial Applications |
API 547 : 2017 | GENERAL PURPOSE FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 185 KW (250 HP) THROUGH 2240 KW (3000 HP) |
ISA 60079-0 : 2005 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
ISA 51.1 : 1979 | PROCESS INSTRUMENTATION TERMINOLOGY |
ISA TR12.06.01 : 1999 | ELECTRICAL EQUIPMENT IN A CLASS 1, DIVISION 2/ZONE 2 HAZARDOUS LOCATION |
ISA 5.1 : 1984 | INSTRUMENTATION SYMBOLS AND IDENTIFICATION |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
ASME A17.1 : 2016 | SAFETY CODE FOR ELEVATORS AND ESCALATORS - INCLUDES REQUIREMENTS FOR ELEVATORS, ESCALATORS, DUMBWAITERS, MOVING WALKS, MATERIAL LIFTS, AND DUMBWAITERS WITH AUTOMATIC TRANSFER DEVICES |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
IEEE 485-2010 | IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
ISA RP12.06.01 : 2003 | RECOMMENDED PRACTICE FOR WIRING METHODS FOR HAZARDOUS (CLASSIFIED) LOCATIONS INSTRUMENTATION - PART 1: INTRINSIC SAFETY |
IEEE 303-2004 | IEEE Recommended Practice for Auxiliary Devices for Rotating Electrical Machines in Class I, Division 2 and Zone 2 Locations |
WC 7-1988 | CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY |
ISA 60079-15 : 2003 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
IEC 60298:1990 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
CSA PLUS 2203 : 2001 | HAZARDOUS LOCATIONS - GUIDE FOR THE DESIGN, TESTING, CONSTRUCTION, AND INSTALLATION OF EQUIPMENT IN EXPLOSIVE ATMOSPHERES |