UNI EN 81-2 : 2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
10-02-2014
01-01-2010
PREMESSA
0 INTRODUZIONE
1 SCOPO E CAMPO DI APPLICAZIONE
2 RIFERIMENTI NORMATIVI
3 TERMINI E DEFINIZIONI
4 UNITA DI MISURA E SIMBOLI
5 VANO DI CORSA
6 SPAZI DEL MACCHINARIO E DELLE PULEGGE DI RINVIO
7 PORTE DI PIANO
8 CABINA E MASSA DI BILANCIAMENTO
9 SOSPENSIONE, COMPENSAZIONE, PRECAUZIONI CONTRO LA DISCESA
A VELOCITA ECCESSIVA E CONTRO IL MOVIMENTO INCONTROLLATO
DELLA CABINA
10 GUIDE, AMMORTIZZATORI E INTERRUTTORE DI EXTRACORSA
11 DISTANZA TRA CABINA E PARETE DEL VANO DI FRONTE ALL'ACCESSO
DI CABINA NONCH? TRA CABINA E MASSA DI BILANCIAMENTO
12 MACCHINARIO
13 INSTALLAZIONI E APPARECCHIATURE ELETTRICHE
14 PROTEZIONE CONTRO I GUASTI ELETTRICI, COMANDI E PRECEDENZE
15 AVVISI, MARCATURE E ISTRUZIONI PER LA MANOVRA
16 CONTROLLI, PROVE, LIBRETTO E MANUTENZIONE
APPENDICE A (normativa) - ELENCO DEI DISPOSITIVI ELETTRICI DI
SICUREZZA
APPENDICE B (normativa) - CHIAVE TRIANGOLARE DI SBLOCCO
APPENDICE C (informativa) - DOCUMENTAZIONE TECNICA
APPENDICE D (normativa) - CONTROLLI E PROVE PRIMA DELLA MESSA
IN SERVIZIO
APPENDICE E (informativa) - CONTROLLI E PROVE PERIODICI,
CONTROLLI E PROVE DOPO UNA TRASFORMAZIONE IMPORTANTE
O DOPO UN INCIDENTE
APPENDICE F (normativa) - COMPONENTI DI SICUREZZA - PROCEDURE
DI PROVA PER LA VERIFICA DELLA CONFORMITA
APPENDICE G (informativa) - VERIFICA DELLE GUIDE
APPENDICE H (normativa) - COMPONENTI ELETTRONICI - ESCLUSIONE
DEI GUASTI
APPENDICE J (normativa) - PROVE D'URTO CON IL PENDOLO
APPENDICE K (normativa) - CALCOLO DEI PISTONI, DEI CILINDRI,
DELLE TUBAZIONI RIGIDE E ACCESSORI
APPENDICE L (informativa) - SPAZI DEL MACCHINARIO - ACCESSO
APPENDICE M (informativa) - DESCRIZIONE DI MISURE POSSIBILI
APPENDICE ZA (informativa) - RAPPORTO FRA LA PRESENTE NORMA
EUROPEA E I REQUISITI ESSENZIALI DELLA DIRETTIVA
UE 95/16/CE MODIFICATA DALLA DIRETTIVA 2006/42/CE
Describes the safety rules for the construction and installation of permanently installed new hydraulic lifts serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by jacks, ropes or chains and moving between guide rails inclined not more than 15 degree to the vertical.
DevelopmentNote |
Superseded by UNI EN 81-20 and UNI EN 81-50, but remains current and will be withdrawn on 31/08/2017. (10/2014)
|
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NS EN 81-2 : 1998 + A3 2009 | Identical |
NBN EN 81-2 : 1998 + A3 2010 | Identical |
BS EN 81-2 : 1998 | Identical |
EN 81-2 : 1998 + A3 2009 | Identical |
SN EN 81-2 : 1998 + A3 2009 | Identical |
I.S. EN 81-2:1999 | Identical |
NF EN 81-2 : 1998 + A3 2010 | Identical |
DIN EN 81-2:2010-08 | Identical |
UNE-EN 81-2:2001 | Identical |
NEN EN 81-2 : 1998 + A3 2010 | Identical |
DIN EN 81-2:2000-05 | Identical |
UNI 11570 : 2015 | INSTRUCTION FOR THE INTEGRATION OF A LIFT SYSTEM FOR A BUILDING |
UNI 10411-2 : 2014 | MODIFICATION OF HYDRAULIC LIFTS NOT COMPLYING WITH DIRECTIVE 95/16/EC |
UNI 11168-2 : 2009 | RAILWAY VEHICLES - ACCESSIBILITY OF USERS TO MASS TRANSIT SYSTEMS - PART 2: DESIGN CRITERIA FOR RAILWAY SYSTEMS |
ISO 6403:1988 | Hydraulic fluid power — Valves controlling flow and pressure — Test methods |
EN 294:1992/AC:1993 | SAFETY OF MACHINERY - SAFETY DISTANCES TO PREVENT DANGER ZONES BEING REACHED BY THE UPPER LIMBS |
EN 12015:2014 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission |
EN 12016:2013 | Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity |
EN 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements |
EN 50214:2006/corrigendum Dec. 2007 | FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES |
EN 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements |
HD 21-3 : S3 AMD 2 2008 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING |
HD 21.5 S3:1994/A2:2001 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 5: FLEXIBLE CABLES (CORDS) |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
EN 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures |
ISO 7465:2007 | Passenger lifts and service lifts — Guide rails for lift cars and counterweights — T-type |
EN 60249-2-3 : 1994 AMD 4 2000 | BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 3: EPOXIDE CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST) |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
HD 384.6.61 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
EN 10025:1990/A1:1993 | HOT ROLLED PRODUCTS OF NON-ALLOY STRUCTURAL STEELS - TECHNICAL DELIVERY CONDITIONS |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
EN 1050 : 1996 | SAFETY OF MACHINERY - PRINCIPLES FOR RISK ASSESSMENT |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
IEC 60747-5:1992 | Semiconductor devices - Discrete devices and integrated circuits -Part 5: Optoelectronic devices |
EN 60742:1995 | Isolating transformers and safety isolating transformers - Requirements |
HD 22-4 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 4: CORDS AND FLEXIBLE CABLES |
EN 60249-2-2 : 1994 AMD 5 2000 | BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 2: PHENOLIC CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET, ECONOMIC QUALITY |
HD 21.1 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
HD 360 : S2 AMD 1 | CIRCULAR RUBBER INSULATED LIFT CABLES FOR NORMAL USE |
EN 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels |
HD 384.5.54 : 200S1 | ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
ISO 1219-1:2012 | Fluid power systems and components — Graphical symbols and circuit diagrams — Part 1: Graphical symbols for conventional use and data-processing applications |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
EN 62326-1:2002 | Printed boards - Part 1: Generic specification |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
HD 21 PT4 : 200S2 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 4: SHEATHED CABLES FOR FIXED WIRING |
EN 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.