UNI EN 15682-2 : 2013
Current
The latest, up-to-date edition.
GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD
10-03-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Evaluation of conformity
6 Marking and/or labelling
Annex A (normative) - Factory production
control
Annex B (normative) - Tests for factory
production control
Annex C (informative) - Provisions for
voluntary involvement of third
party(ies)
Annex ZA (informative) - Clauses of this
European Standard addressing the
provisions of EU Construction
Products Directive
Bibliography
Defines requirements, the evaluation of conformity and the factory production control of flat heat soaked thermally toughened alkaline earth silicate safety glass for use in buildings.
Committee |
U58.00.01
|
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Current
|
Standards | Relationship |
EN 15682-2:2013 | Identical |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12898:2001 | Glass in building - Determination of the emissivity |
EN 13501-5:2016 | Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests |
EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
PREN 16612 : DRAFT 2017 | GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 14178-2:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 2: Evaluation of conformity/Product standard |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
ISO 9001:2015 | Quality management systems — Requirements |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 15682-1:2013 | Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.