UNI CEI EN 13757-5 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 5: WIRELESS RELAYING
12-10-2015
01-01-2009
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Explanation
4.1 General
4.2 Introduction
4.3 Relaying
4.4 Use of routers
4.5 Use of gateways
4.5.1 General
4.5.2 Data duplication
4.6 Use of power strobed units
4.7 Error handling
4.8 Time synchronisation
4.9 Protocol possibilities
5 Mode P, protocol using routers
5.1 General
5.2 Physical layer protocol
5.2.1 General
5.2.2 Transmitter
5.2.3 Receiver
5.3 Data encoding
5.3.1 Manchester encoding
5.3.2 Order of transmission of the encoded data
5.3.3 Wake up and preamble chip sequences
5.4 Data link layer protocol
5.4.1 General
5.4.2 Frame format
5.4.3 C-field
5.4.4 M- and A-fields
5.4.5 The CI-field
5.4.6 Message handling
5.4.7 Timing requirements
5.5 Network layer protocol
5.5.1 General
5.5.2 Network layer format
5.5.3 Relaying rules
5.6 Application layer protocol
5.6.1 CI-field
5.6.2 Error reporting services
5.6.3 Network management service
6 Mode R2, protocol using gateways
6.1 General
6.2 Physical layer protocols
6.3 Data link layer protocol
6.3.1 General
6.3.2 M- and A-field
6.3.3 C-field
6.3.4 Timing requirements
6.3.5 Error handling
6.4 Network layer functionality
6.4.1 General
6.4.2 Downstream transfer
6.4.3 Downstream relaying rules
6.4.4 Upstream transfer
6.4.5 Upstream relaying rules
6.5 Application layer
6.5.1 CI-field
6.5.2 Network management services
7 Mode Q, protocol supporting precision timing
7.1 General
7.2 Physical layer protocol
7.2.1 General
7.2.2 Transmitter
7.2.3 Receiver
7.3 Data encoding
7.3.1 NRZ encoding
7.3.2 Order of transmission of the encoded data
7.3.3 Wake up and preamble bit sequences
7.4 Data link layer protocol
7.4.1 General
7.4.2 Frame format
7.4.3 Normal data link layer frame handling
7.4.4 Search link layer frame handling
7.5 Mode Q, network layer protocol
7.5.1 General
7.5.2 Network layer format
7.5.3 Address conversion rules
7.5.4 Routing rules
7.5.5 Timing requirements
7.6 Mode Q, application layer protocol
7.6.1 General
7.6.2 EN 13757-1 Application layer
7.6.3 Error reporting
7.6.4 Alarm reporting
7.6.5 Network management service
7.6.6 Timing requirements
7.6.7 COSEM extension
Bibliography
Describes the requirements for the protocols to use when performing relaying in wireless meter readout networks. Being an extension to Part 4 of EN 13757, Wireless meter readout (Radio meter reading for operation in the 868 MHz to 870 MHz SRD band) supports the routing of mode R2, but the routing of mode S and T is not supported.
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 13757-5:2015 | Identical |
UNI/TS 11291-11-4 : 2014 | GAS MEASUREMENT SYSTEMS - HOURLY BASED GAS METERING SYSTEMS - PART 11-4: COMMUNICATION PROFILE PM1 |
UNI/TS 11291-11-5 : 2014 | GAS MEASUREMENT SYSTEMS - HOURLY BASED GAS METERING SYSTEMS - PART 11-5: COMMUNICATION PROFILE PP3 |
EN 60870-5-2:1993 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 2: Link transmission procedures |
IEC 62054-21:2004+AMD1:2017 CSV | Electricity metering (AC) - Tariff and load control - Part 21: Particular requirements for time switches |
EN 60870-5-1:1993 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 1: Transmission frame formats |
EN 301 489-3 : 1.6.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 3: SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD) OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 246 GHZ |
EN 13757-4:2013 | Communication systems for meters and remote reading of meters - Part 4: Wireless meter readout (Radio meter reading for operation in SRD bands) |
IEC 60870-5-2:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 2: Link transmission procedures |
EN 300 220-2 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1 000 MHZ - PART 2: HARMONISED STANDARD FOR ACCESS TO RADIO SPECTRUM FOR NON SPECIFIC RADIO EQUIPMENT |
IEC 60870-5-1:1990 | Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats |
IEEE 1588-2008 REDLINE | IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems |
EN 300 220-1 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT |
EN 13757-1:2014 | Communication systems for meters - Part 1: Data exchange |
EN 301 489-1 : 2.1.1 | ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 1: COMMON TECHNICAL REQUIREMENTS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU AND THE ESSENTIAL REQUIREMENTS OF ARTICLE 6 OF DIRECTIVE 2014/30/EU |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.