UNE-HD 60364-7-717:2013
Current
Current
The latest, up-to-date edition.
Low-voltage electrical installations -- Part 7-717: Requirements for special installations or locations - Mobile or transportable units
Available format(s)
Hardcopy , PDF
Published date
02-13-2013
Publisher
Committee |
CTN 202/SC 64
|
DevelopmentNote |
Supersedes UNE 20460-7-717. (02/2013)
|
DocumentType |
Standard
|
Pages |
24
|
ProductNote |
NEW CHILD AC 2014 IS ADDED
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
Supersedes |
Standards | Relationship |
HD 60364-7-717:2010 | Identical |
HD 60364-7-717:2010/AC:2014 | Identical |
IEC 60227-4:1992+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring |
EN 61386-21:2004/A11:2010 | CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 21: PARTICULAR REQUIREMENTS - RIGID CONDUIT SYSTEMS |
EN 61386-22 : 2004 AMD 11 2010 | CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 22: PARTICULAR REQUIREMENTS - PLIABLE CONDUIT SYSTEMS |
HD 21-3 : S3 AMD 2 2008 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
EN 61386-23:2004/A11:2010 | CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 23: PARTICULAR REQUIREMENTS - FLEXIBLE CONDUIT SYSTEMS |
IEC 60092-507:2014 | Electrical installations in ships - Part 507: Small vessels |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 61386-21:2002 | Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
HD 22-4 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 4: CORDS AND FLEXIBLE CABLES |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 61386-23:2002 | Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
HD 60364-5-551:2010/A11:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-55: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - OTHER EQUIPMENT - CLAUSE 551: LOW-VOLTAGE GENERATING SETS |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 61557-8:2015/AC:2016-06 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
EN 60309-2:1999/A2:2012 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012) |
EN 61557-9:2015/AC:2017-02 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
IEC 61386-22:2002 | Conduit Systems for cable management - Part 22: Particular requirements - Pliable conduit systems |
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories |
EN 60309-1:1999/A1:2007/AC:2014 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-