Acoustics - Statistical distribution of hearing thresholds related to age and gender (ISO 7029:2017)
Hardcopy , PDF
11-29-2017
This International Standard provides descriptive statistics of the hearing threshold for populations of otologically normal persons of various ages under monaural earphone listening conditions. It specifies the following, for populations within the age limits from 18 years to 80 years inclusive for the range of audiometric frequencies from 125 Hz to 8 000 Hz:
a)the expected median value of hearing thresholds given relative to the median hearing threshold at the age of 18 years;
b)the expected statistical distribution above and below the median value.
For the frequencies from 3 000 Hz to 8 000 Hz, the median and statistical distribution for populations above 70 years are presented for information only.
This International Standard also provides for information the expected median values at audiometric frequencies from 9 000 Hz to 12 500 Hz within the age limits from 22 years to 80 years inclusive.
The data are applicable for estimating the amount of hearing loss caused by a specific agent in a population. Such a comparison is valid if the population under study consists of persons who are otologically normal except for the effect of the specific agent. Noise exposure is an example of a specific agent and for this application selected data from this International Standard are referred to as database A in ISO 1999.
NOTE 1Database A in ISO 1999:2013 is based on a previous edition of ISO 7029.
The data may also be used to assess an individual s hearing in relation to the distribution of hearing thresholds which is normal for the person s age group. However, it is not possible to determine for an individual precisely which part of an observed hearing loss is attributable to an accumulation of detrimental effects on the hearing which increase with age, and which part has been caused by other factors such as noise.
The hearing threshold deviation as defined herein and the hearing threshold level as defined in other standards (ISO 389-1, ISO 389-2, ISO 389-5, ISO 389-8, ISO 8253-1, ISO 8253-2, IEC 60645-1) express the hearing threshold of an individual or an individual ear, respectively, relative to,
-ðthe median hearing threshold of a population of 18-year-old persons, or
-ða reference zero level specified in various parts of ISO 389.
To the extent that the reference zero level represents the median of the 18-year-old population, the values of the two terms will be the same.
NOTE 2Those two terms are not always the same for some reasons. One reason is that the reference zero level has been determined based on the hearing threshold levels of persons older than 18 years, including those aged up to 25 years or to 30 years, who have slightly worse hearing sensitivity on average.
NOTE 3ISO 28961 specifies the expected statistical distribution of hearing thresholds, expressed in sound pressure level in decibels, for populations of otologically normal persons of the age from 18 years to 25 years under binaural, free-field listening conditions. It enables the calculation not only at audiometric frequencies, but also for other frequencies at one-third-octave intervals from 20 Hz to 16 000 Hz.
| Committee |
CTN 74/SC 1
|
| DevelopmentNote |
Supersedes UNE 74152 (08/2003)
|
| DocumentType |
Standard
|
| Pages |
30
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| NS EN ISO 7029 : 2017 | Identical |
| ISO 7029:2017 | Identical |
| NEN EN ISO 7029 : 2017 | Identical |
| ONORM EN ISO 7029 : 2017 | Identical |
| BS EN ISO 7029:2017 | Identical |
| DIN EN ISO 7029:2001-01 | Identical |
| I.S. EN ISO 7029:2017 | Identical |
| EN ISO 7029:2017 | Identical |
| NF EN ISO 7029 : 2017 | Identical |
| NBN EN ISO 7029 : 1ED 2000 | Identical |
| IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
| ISO 28961:2012 | Acoustics — Statistical distribution of hearing thresholds of otologically normal persons in the age range from 18 years to 25 years under free-field listening conditions |
| ISO 389-8:2004 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones |
| ISO 389-5:2006 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz |
| ISO 389-1:1998 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones |
| ISO 8253-1:2010 | Acoustics — Audiometric test methods — Part 1: Pure-tone air and bone conduction audiometry |
| ISO 389-2:1994 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
| ISO 1999:2013 | Acoustics — Estimation of noise-induced hearing loss |
| ANSI S3.6 : 2010 | SPECIFICATION FOR AUDIOMETERS |
| ISO 8253-2:2009 | Acoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test signals |