1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Documentation
4.2 Qualifications of personnel
4.3 Inspections
4.4 Regular periodic inspections
4.5 Continuous supervision by skilled persons
4.6 Maintenance requirements
4.7 Environmental conditions
4.8 Isolation of apparatus
4.9 Earthing and equipotential bonding
4.10 Conditions of use
4.11 Movable apparatus and its connections
4.12 Inspection schedules
5 Additional inspection schedule requirements
5.1 Type of protection 'd' - Flameproof enclosure
5.2 Type of protection 'e' - Increased safety
5.3 Type of protection 'i' - Intrinsic safety
5.4 Type of protection 'p' - Pressurized enclosure
5.5 Apparatus used in zone 2
5.6 Types of protection 'm' (encapsulation),
'o' (oil-immersion) and 'q' (powder-filling)
Annex A (informative) Typical inspection procedure for periodic
inspections
Annex ZA (normative) Normative references to international
publications with their corresponding European publications
Applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings.
Committee |
CTN 202/SC 31
|
DevelopmentNote |
Supersedes UNE EN 61241-17. (09/2010)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 60079-17:2014 | Identical |
NF EN 60079-17 : 2014 | Identical |
NBN EN 60079-17 : 2014 | Identical |
SN EN 60079-17 : 2003 | Identical |
IEC 60079-17:2013 | Identical |
I.S. EN 60079-17:2014 | Identical |
BS EN 60079-17:2014 | Identical |
DIN EN 60079-17 : 2014 | Identical |
UNE 60312:2015 | Gas pressure regulating stations for distribution of gas supply at an inlet pressure not above 16 bar. |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 61241-4:2006 | Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD" |
EN 60079-1:2014 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
EN 60079-19:2011/A1:2015 | EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION (IEC 60079-19:2010) |
ISO 31000:2009 | Risk management Principles and guidelines |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
EN 60079-10-2:2015 | Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
EN 60079-31:2014 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 61241-4:2001 | Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD" |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
IEC 60079-31:2013 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
EN 60079-2:2014/AC:2015 | EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014) |
Access your standards online with a subscription