PROLOGO
1 OBJETO Y CAMPO DE APLICACION
2 NORMAS PARA CONSULTA
3 TÉRMINOS, DEFINICIONES Y SIMBOLOS
4 CLASIFICACION
5 REQUISITOS
6 MÉTODOS DE ENSAYO
7 MARCADO
8 EVALUACION DE LA CONFORMIDAD
ANEXO A (Normativo) - REQUISITOS DE LOS ENSAYOS DE RESISTENCIA
AL FUEGO/HUMO
ANEXO B (Normativo) - SECUENCIAS Y MUESTREO DE ENSAYO
ANEXO C (Normativo) - INSTRUCCIONES DE INSTALACION Y FIJACION
ANEXO ZA (Normativo) - CAPITULOS DE ESTA NORMA EUROPEA RELATIVOS
A LOS REQUISITOS ESENCIALES DE LA DIRECTIVA DE
PRODUCTOS DE CONSTRUCCION DE LA UE (89/106/CEE)
BIBLIOGRAFIA
Esta norma europea especifica los requisitos y métodos de ensayo relativos a la resistencia, seguridad, durabilidad y funcionamiento de los componentes eléctricos y electrónicos de todo tipo de cerraduras y cerraderos maniobrados electromecánicamente utilizados en puertas, balconeras y puertas de entrada en edificios.
Committee |
CTN 85
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
Standards | Relationship |
EN 14846:2008 | Identical |
UNE 85160:2017 | Security doors and hardware. Minimum requirements related to protection and resistance class. Selection, application and installation criteria. |
EN 1906:2012 | Building hardware - Lever handles and knob furniture - Requirements and test methods |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 1303:2015 | Building hardware - Cylinders for locks - Requirements and test methods |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 12209:2016 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 12320:2012 | Building hardware - Padlocks and padlock fittings - Requirements and test methods |
PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 9001:2015 | Quality management systems — Requirements |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |