• There are no items in your cart

UL 1424:4ED 2015-01-22

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Cables for Power-Limited Fire-Alarm Circuits

Available format(s)

Hardcopy

Superseded date

10-08-2024

Superseded by

UL 1424:5ED 2024-10-08

Language(s)

English

Published date

01-22-2015

US$637.31
Excluding Tax where applicable

Foreword
Introduction
1 Scope
2 Units of measurement
3 References and terms
Construction
4 Materials
5 Conductors
6 Metal coating
7 Insulation
8 Coaxial and optical-fiber members
9 Individual covering
10 Electromagnetic shield(s)
11 Binder(s)
12 Assembly of multiple-conductor cable
13 Cable jacket
14 Metal covering
15 Jacket over metal covering
Performance
16 Continuity test of conductors and Shields
17 D-C resistance test of copper conductors
18 Cold bend test of insulation
19 Cold bend test of complete cable
20 Smoke and fire testing of type FPLP cable
21 Fire testing of type FPLR cable
22 VW-1 (vertical-specimen) flame test
23 Alternative vertical-tray flame tests on type FPL
    cable
24 Sunlight resistance test
25 Spark test after insulating
26 Dielectric voltage-withstand test
27 Test for insulation resistance at 60.0 deg F (15.6
    deg C)
28 Test procedure for determining the multiplying-
    factor column for adjusting insulation resistance
29 Shrinkback test on thermoplastic insulation
30 Crushing resistance test of insulation
31 Crushing test for cable marked for direct burial
32 Mechanical water absorption test of insulation in
    direct-burial cable
33 Copper sulphate test of zinc coating on steel strip
    for and from interlocked steel armor
34 Abrasion resistance test of overall jacket on cable
    consisting of a single coaxial member
35 Tension test of interlocked steel or aluminium armor
36 Flexibility test for cable having interlocked armor
    or a smooth or corrugated metal sheath
37 Durability test of ink printing
Markings
38 Intervals
39 Coding
40 Information on or in the cable
41 Information on the tag, reel, or carton
42 Multiple markings

Specifies 60 - 250 degrees C (140 - 482 degrees F) single- and multiple-conductor cables for use as fixed wiring within buildings (some are also marked for direct burial) principally for power-limited fire-alarm circuits as described in Article 760 and other applicable parts of the National Electrical Code (NEC).

DocumentType
Standard
Pages
0
PublisherName
Underwriters Laboratories
Status
Superseded
SupersededBy

UL 2196:2ED 2017-08-29 Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
UL 1655:2ED 2009-04-21 Standard for Community-Antenna Television Cables
UL 1690:4ED 2015-07-07 Data-Processing Cable
UL 1425:3ED 2015-01-26 Cables for Non-Power-Limited Fire-Alarm Circuits

UL 1685:4ED 2015-07-07 Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables
UL 444:5ED 2017-01-20 Communications Cables
UL 2196:2ED 2017-08-29 Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables
UL 1666:5ED 2007-02-16 Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts
UL 13:4ED 2015-03-18 Power-Limited Circuit Cables

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.