• There are no items in your cart

TS 100 623 : 8.0.0

Current

Current

The latest, up-to-date edition.

DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+); NETWORK MANAGEMENT (NM) PROCEDURES AND MESSAGES ON THE A-BIS INTERFACE

Available format(s)

Hardcopy , PDF

Language(s)

English

US$52.09
Excluding Tax where applicable

Intellectual Property Rights
Foreword
Foreword
Introduction
1 Scope
2 References
3 Definitions and abbreviations
  3.1 Definitions
  3.2 Abbreviations
4 Functional Split between BSC and BTS
5 Information Model
  5.1 Managed Objects
  5.2 Addressing of Objects
  5.3 State Management of Objects
      5.3.1 Administrative State
      5.3.2 Operational State and Availability Status
6 Elementary Procedure
  6.1 Definition of the Procedure
  6.2 SW Download Management Procedures
       6.2.1 Load Data Initiate
       6.2.2 Load Data Segment
       6.2.3 Load Data Abort
       6.2.4 Load Data End
       6.2.5 SW Activate Request
       6.2.6 Activate SW
       6.2.7 SW Activated Report
  6.3 A-bis Interface Management Procedures
       6.3.1 Establish TEI
       6.3.2 Connect Terrestrial Signalling
       6.3.3 Disconnect Terrestrial Signalling
       6.3.4 Connect Terrestrial Traffic
       6.3.5 Disconnect Terrestrial Traffic
  6.4 Transmission Management Procedures
       6.4.1 Connect Multi-drop
       6.4.2 Disconnect Multi-drop Link
  6.5 Air Interface Management Procedures
       6.5.1 Set BTS Attributes
       6.5.2 Set Radio Carrier Attributes
       6.5.3 Set Channel Attributes
  6.6 Test Management Procedure
       6.6.1 Perform Test
       6.6.2 Test Report
       6.6.3 Send Test Report
       6.6.4 Stop Test
  6.7 State Management and Event Report Procedures
       6.7.1 State Changed Event Report
       6.7.2 Failure Event Report
       6.7.3 Stop Sending Event Reports
       6.7.4 Restart Sending Event Reports
       6.7.5 Change Administrative State
       6.7.6 Change Administrative State Request
       6.7.7 Report Outstanding Alarms
  6.8 Equipment Management Procedures
       6.8.1 Change-over
       6.8.2 Opstart
       6.8.3 Reinitialize
       6.8.4 Set Site Outputs
  6.9 Measurement Management Procedures
       6.9.1 Measurement Result Request
       6.9.2 Measurement Result Response
       6.9.3 Stop Measurement
       6.9.4 Start Measurement
  6.10 Miscellaneous Procedures
       6.10.1 Get Attributes
       6.10.2 Set Alarm Threshold
       6.10.3 Get Attributes Response
7 Structured Procedure
8 Message Details
  8.1 Message Categories
       8.1.1 Formatted O&M Messages
       8.1.2 MMI Transfer
       8.1.3 TRAU O&M Messages
       8.1.4 Manufacturer-Defined O&M messages
  8.2 Structure of Formatted O&M Messages
  8.3 SW Download Management Messages
       8.3.1 Load Data Initiate
       8.3.2 Load Data Segment
       8.3.3 Load Data Abort
       8.3.4 Load Data End
       8.3.5 SW Activate Request
       8.3.6 Activate SW
       8.3.7 SW Activated Report
  8.4 A-bis Interface Management Messages
       8.4.1 Establish TEI
       8.4.2 Connect Terrestrial Signalling
       8.4.3 Disconnect Terrestrial Signalling
       8.4.4 Connect Terrestrial Traffic
       8.4.5 Disconnect Terrestrial Traffic
  8.5 Transmission Management Messages
       8.5.1 Connect Multi-drop link
       8.5.2 Disconnect Multi-drop link
  8.6 Air Interface Management Messages
       8.6.1 Set BTS Attributes
       8.6.2 Set Radio Carrier Attributes
       8.6.3 Set Channel Attributes
  8.7 Test Management Messages
       8.7.1 Perform Test
       8.7.2 Test Report
       8.7.3 Send Test Report
       8.7.4 Stop Test
  8.8 State Management and Event Report Messages
       8.8.1 State Changed Event Report
       8.8.2 Failure Event Report
       8.8.3 Stop Sending Event Reports
       8.8.4 Restart Sending Event Reports
       8.8.5 Change Administrative State
       8.8.6 Change Administrative State Request
       8.8.7 Report Outstanding Alarms
  8.9 Equipment Management Messages
       8.9.1 Changeover
       8.9.2 Opstart
       8.9.3 Reinitialize
       8.9.4 Set Site Outputs
       8.9.5 Change HW Configuration
  8.10 Measurement Management Messages
       8.10.1 Measurement Result Request
       8.10.2 Measurement Result Response
       8.10.3 Start Measurement
       8.10.4 Stop Measurement
  8.11 Miscellaneous Messages
       8.11.1 Get Attributes
       8.11.2 Set Alarm Threshold
       8.11.3 Get Attribute Response
9 Coding
  9.1 Message Type
  9.2 Object Class
  9.3 Object Instance
  9.4 Attributes and Parameters
      9.4.1 Abis Channel
      9.4.2 Additional Info
      9.4.3 Additional Text
      9.4.4 Administrative State
      9.4.5 ARFCN List
      9.4.6 Autonomously Report
      9.4.7 Availability Status
      9.4.8 BCCH ARFCN
      9.4.9 BSIC
      9.4.10 BTS Air Timer
      9.4.11 CCCH Load Indication Period
      9.4.12 CCCH Load Threshold
      9.4.13 Channel Combination
      9.4.14 Connection Failure Criterion
      9.4.15 Destination
      9.4.16 Event Type
      9.4.17 File Data
      9.4.18 File Id
      9.4.19 File Version
      9.4.20 GSM Time
      9.4.21 HSN
      9.4.22 HW Configuration
      9.4.23 HW Description
      9.4.24 Intave Parameter
      9.4.25 Interference level Boundaries
      9.4.26 List of Required Attributes
      9.4.27 MAIO
      9.4.28 Manufacturer Dependent State
      9.4.29 Manufacturer Dependent Thresholds
      9.4.30 Manufacturer Id
      9.4.31 Max Timing Advance
      9.4.32 Measurement Result
      9.4.33 Measurement Type
      9.4.34 Multi-drop BSC Link
      9.4.35 Multi-drop next BTS Link
      9.4.36 Nack Causes
      9.4.37 Ny1
      9.4.38 Operational State
      9.4.39 Overload Period
      9.4.40 Physical Configuration
      9.4.41 Power Class
      9.4.42 Power Output Thresholds
      9.4.43 Probable Cause
      9.4.44 RACH Busy Thresholds
      9.4.45 RACH Load Averaging Slots
      9.4.46 Radio Sub Channel
      9.4.47 RF Max Power Reductions
      9.4.48 Site Inputs
      9.4.49 Site Outputs
      9.4.50 Source
      9.4.51 Specific Problems
      9.4.52 Starting Time
      9.4.53 T200
      9.4.54 TEI
      9.4.55 Test Duration
      9.4.56 Test No
      9.4.57 Test Report Info
      9.4.58 VSWR Thresholds
      9.4.59 Window Size
      9.4.60 TSC
      9.4.61 SW Configuration
      9.4.62 SW Description
      9.4.63 Perceived Severity
      9.4.64 Get Attribute Response Info
      9.4.65 Outstanding Alarm Sequence
      9.4.66 HW Conf Change Info
Annex A (informative): Change history
History

Addresses the network management messages and procedures across the A-bis interface, which is defined as Qx in GSM.

Committee
3GPP GERAN
DocumentType
Standard
Pages
65
PublisherName
European Telecommunications Standards Institute
Status
Current

ETSI GSM 04.08 : 050300 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+) - MOBILE RADIO INTERFACE LAYER 3 SPECIFICATION
ETSI GSM 12.01 : 4.4.0 COMMON ASPECTS OF GSM NETWORK MANAGEMENT
ETSI GSM 12.06 : 4.0.0 GSM NETWORK CHANGE CONTROL
ETSI GSM 01.04 : 050000 EUROPEAN DIGITAL CELLULAR TELECOMMUNICATION SYSTEM (PHASE 2); DEFINITIONS, ABBREVIATIONS AND ACRONYMS
ETSI GSM 12.00 : 4.3.1 OBJECTIVES AND STRUCTURE OF NETWORK MANAGEMENT
ETSI GSM 12.22 : 4.2.0 DIGITAL CELLULAR TELECOMMUNICATION SYSTEM (PHASE 2); INTERWORKING OF GSM NETWORK MANAGEMENT (NM) PROCEDURES AND MESSAGES AT THE BASE STATION CONTROLLER (BSC)
ETSI GSM 08.56 : 050000 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM; BASE STATION CONTROLLER - BASE TRANSCEIVER STATION (BSC-BTS) INTERFACE; LAYER 2 SPECIFICATION
ETSI GSM 12.20 : 4.5.1 NETWORK MANAGEMENT PROCEDURES AND MESSAGES
ETSI GSM 08.52 : 050000 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM; BASE STATION CONTROLLER - BASE TRANSCEIVER STATION (BSC-BTS) INTERFACE; INTERFACE PRINCIPLES
ETSI GSM 05.08 : 050100 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+); RADIO SUBSYSTEM LINK CONTROL (GSM 05.08)
ETSI GSM 05.02 : 050100 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+) - MULTIPLEXING AND MULTIPLE ACCESS ON THE RADIO PATH
ETSI GSM 04.06 : 4.4.0 MS-BSS DATA LINK LAYER SPECIFICATION
ETSI GSM 08.51 : 050000 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM; BASE STATION CONTROLLER - BASE TRANSCEIVER STATION (BSC-BTS) INTERFACE; GENERAL ASPECTS
ETSI GSM 08.58 : 051000 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+); BASE STATION CONTROLLER - BASE TRANSCEIVER STATION (BSC-BTS) INTERFACE; LAYER 3 SPECIFICATION
ETSI GSM 05.05 : 050200 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+); RADIO TRANSMISSION AND RECEPTION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.