SN EN 60601-2-29 : 2008 AMD 11 2011
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS
01-12-2013
INTRODUCTION
SECTION ONE - GENERAL
1 Scope and object
2 Terminology and definitions
5 Classification
6 Identification, marking and documents
SECTION TWO - ENVIRONMENTAL CONDITIONS
10 Environmental conditions
SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
16 ENCLOSURES and PROTECTIVE COVERS
18 Protective earthing, functional earthing and potential
equalization
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
CURRENTS
SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
22 Moving parts
27 Pneumatic and hydraulic power
28 Suspended masses
SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR
EXCESSIVE RADIATION
29 X-RADIATION generated by SIMULATORS
36 ELECTROMAGNETIC COMPATIBILITY
SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF
FLAMMABLE ANAESTHETIC MIXTURES
SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS;
ENVIRONMENTAL TESTS
52 Abnormal operation and fault conditions
Appendix L (normative) References - Publications mentioned
in this standard
Annex AA (normative) Terminology - Index of defined terms
Annex BB (informative) Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Annex ZB (informative) Other international publications
mentioned in this standard with the
references of the relevant European
publication
Table 101 - Clauses and subclauses in this Particular
Standard that require the provision of
information in the ACCOMPANYING DOCUMENTS, the
INSTRUCTIONS FOR USE, and in the technical
description
Figure 101 - EQUIPMENT movements and scales - Rotary GANTRY
(adapted from IEC 60601-2-1) with identification
of axes 1 to 8, directions 9 to 13, and
dimensions 14 and 15
Figure 102 - EQUIPMENT movements and scales - ISOCENTRIC
RADIOTHERAPY SIMULATOR or TELERADIOTHERAPY
EQUIPMENT, with identification of axes 1; 4 to
6; 19, of directions 9 to 12; 16 to 18 and of
dimensions 14; 15
Figure 103 - EQUIPMENT movements and scales - View from
RADIATION SOURCE of TELERADIOTHERAPY RADIATION
FIELD or RADIOTHERAPY SIMULATOR DELINEATED
RADIATION FIELD
In addition to the clauses and subclauses of the General Standard, this applies to radiotherapy simulators using diagnostic X-ray equipment to simulate physically a radiotherapy radiation beam in order that the treatment volume to be subjected to irradiation during radiotherapy can be localized, and the size and position of the radiotherapy radiation field can be confirmed. It is intended exclusively for radiotherapy simulation as a prelude to intended radiotherapy. To be used within the environmental and electrical supply conditions specified in the technical description.
DocumentType |
Standard
|
PublisherName |
Swiss Standards
|
Status |
Current
|
Standards | Relationship |
UNE-EN 60601-2-29:2009 | Identical |
IEC 60601-2-29:2008 | Identical |
DIN EN 60601-2-29 : 2009 | Identical |
EN 60601-2-29:2008/A11:2011 | Identical |
NF EN 60601-2-29 : 2009 AMD 11 2012 | Identical |
BS EN 60601-2-29 : 2008 | Identical |
I.S. EN 60601-2-29:2008 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.