SA TR IEC 63170:2020
Current
The latest, up-to-date edition.
Measurement procedure for the evaluation of power density related to human exposure to radio frequency fields from wireless communication devices operating between 6 GHz and 100 GHz
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
09-11-2020
This document adopts IEC TR 63170:2018, which describes the state of the art measurement techniques and test approaches for evaluating the local and spatial-average incident power density of wireless devices operating in close proximity to the users between 6 GHz and 100 GHz.
Committee |
TE-007
|
DocumentType |
Technical Report
|
ISBN |
978 1 76072 969 1
|
Pages |
89
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This document describes the state of the art measurement techniques and test approaches
for evaluating the local and spatial-average incident power density of wireless devices
operating in close proximity to the users between 6 GHz and 100 GHz.
In particular, this document provides guidance for testing portable devices in applicable
operating position(s) near the human body, such as mobile phones, tablets, wearable devices,
etc. The methods described in this document may also apply to exposures in close proximity
to base stations.
This document also gives guidance on how to assess exposure from multiple simultaneous
transmitters operating below and above 6 GHz (including combined exposure of SAR and
power density).
NOTE Compliance of devices with sufficiently low radiated power that is incapable of exceeding basic restrictions
is addressed by IEC 62479 [2] and therefore not described in this document.
Standards | Relationship |
IEC TR 63170:2018 | Identical |
First published as SA TR IEC 63170:2020.
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
IEC 62209-2:2010 | Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) |
IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
IEC 62232:2017 | Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO/IEC 17025:2017 | General requirements for the competence of testing and calibration laboratories |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.