GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 2: PRODUCT STANDARD
11-28-2017
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Assessment and verification of constancy of
performance - AVCP
6 Marking and/or labelling
Annex A (normative) - Factory production control
Annex B (informative) - Tests for factory production
control
Annex C (normative) - Type testing of spectrophotometric
and energy characteristics
Annex D (normative) - Type testing and sampling for
fragmentation, mechanical strength and pendulum
body impact tests
Annex E (informative) - Provisions for voluntary
involvement of third party(ies)
Annex ZA (informative) - Relationship of this European
Standard with Regulation (EU) No.305/2011
Bibliography
Describes the assessment and verification of constancy of performances and the factory production control of flat heat soaked thermally toughened soda lime silicate safety glass for use in buildings.
Committee |
TC 129
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
17/30365062 DC | Identical |
01/105367 DC : DRAFT JULY 2001 | Identical |
03/100998 DC : DRAFT MAR 2003 | EN 13022-3 - GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 3: ASSEMBLY RULES |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 14179-1:2016 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12898:2001 | Glass in building - Determination of the emissivity |
305/2011 : 2011 AMD 2 2014 | REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE) |
EN 13501-5:2016 | Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
PREN 16612 : DRAFT 2017 | GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
ISO 9385:1990 | Glass and glass-ceramics Knoop hardness test |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 15998:2010 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
Access your standards online with a subscription