NS EN 1520 : 2011
Current
The latest, up-to-date edition.
PREFABRICATED REINFORCED COMPONENTS OF LIGHTWEIGHT AGGREGATE CONCRETE WITH OPEN STRUCTURE WITH STRUCTURAL OR NON-STRUCTURAL REINFORCEMENT
01-12-2013
Foreword
1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
3.1 Terms and definitions
3.2 Symbols
3.3 Abbreviations
3.4 Units
4 Properties and requirements of materials
4.1 Constituents
4.2 Reinforcing steel
4.3 Lightweight aggregate concrete parameters
5 Properties and requirements of components
5.1 General
5.2 Types of components
5.3 Detailing, technical requirements, and declared
properties
5.4 Additional requirements for roof and floor
components and beams
5.5 Additional requirements for loadbearing wall
components with no vertical load
5.6 Additional requirements for loadbearing wall
components with vertical loads
5.7 Additional requirements for non-loadbearing
wall components for partitions
5.8 Durability
6 Evaluation of conformity
6.1 Introduction
6.2 Initial type-testing of the component
6.3 Factory production control
6.4 Initial inspection of the factory and the factory
production control
6.5 Surveillance, assessment and approval of the
factory production control
6.6 Actions to be taken in the event of non-conformity
7 Basis for evaluation
7.1 Evaluation methods
7.2 Limit states
7.3 Actions
8 Marking, labelling and designation
8.1 Standard designation
8.2 Additional information on accompanying documents
Annex A (normative) Evaluation by calculation
A.1 General
A.2 Partial safety factors
A.3 Ultimate limit state - Design for bending and
combined bending and axial compression
A.4 Ultimate limit state - Design for shear
A.5 Ultimate limit state - Design for centric and
eccentric axial compression forces
A.6 Serviceability limit states
A.7 Components requirements
Annex B (normative) Evaluation by testing
B.1 General
B.2 Safety evaluation
B.3 Ultimate limit states
B.4 Serviceability limit states
Annex C (informative) Partial safety factors (Example)
C.1 Ultimate limit states (ULS)
C.2 Serviceability limit states (SLS)
Annex ZA (informative) Provisions for the CE marking of
prefabricated reinforced components of lightweight
aggregate concrete with open structure under the
EC Construction Product Directive
Bibliography
Figures
Tables
Describes prefabricated components of lightweight aggregate concrete (LAC) with open structure and with structural or non-structural reinforcement intended to be used in building construction a) for structural elements: - loadbearing wall components (solid, hollow core or multilayer); - retaining wall components (solid) with or without surcharge loading; - roof components solid, hollow core or multilayer); - floor components (solid, hollow core or multilayer); - linear components (beams or piers). b) for non-structural elements: - non-loadbearing wall components (e.g. for partition walls); - cladding components (without fixtures) intended to be used for external facades of buildings; - small box culverts used to form channels for the enclosure of services; - components for noise barriers.
DocumentType |
Standard
|
PublisherName |
Norwegian Standards (Norges Standardiseringsforbund)
|
Status |
Current
|
Standards | Relationship |
BS EN 1520:2011 | Identical |
EN 1520:2011 | Identical |
I.S. EN 1520:2011 | Identical |
DIN EN 1520:2011-06 | Identical |
UNE-EN 1520:2003 | Identical |
UNI EN 1520 : 2011 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.