NS EN 1366-3 : 2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
01-07-2022
01-12-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
5.1 Heating conditions
5.2 Pressure conditions
6 Test specimen
6.1 General
6.2 Size
6.3 Number
6.4 Design
6.4.1 General
6.4.2 Support conditions for penetrating services
6.4.3 Pipe end configuration
6.4.4 Cable end configuration
6.4.5 Blank penetration seal
6.4.6 Subsequent addition of services
6.5 Construction
6.6 Verification
7 Installation of test specimen
7.1 General
7.2 Supporting construction
7.2.1 General
7.2.2 Standard supporting constructions
7.3 Installation of service
7.4 Installation of penetration seal
7.5 Multiple test specimens
8 Conditioning
9 Application of instrumentation
9.1 Thermocouples
9.1.1 Furnace thermocouples (plate thermometers)
9.1.2 Unexposed face thermocouples
9.1.3 Roving thermocouple
9.2 Integrity measurement
9.3 Pressure
10 Test procedure
10.1 General
10.2 Integrity
10.3 Insulation
10.4 Other observations
11 Performance criteria
11.1 Integrity
11.2 Insulation
11.3 Multiple penetrations
12 Test report
13 Field of direct application of test results
Annex A (informative) Explanatory notes
A.1 General
A.2 Notes on the scope and application of test results
A.3 Notes on test conditions
A.4 Notes on test construction
A.5 Suggested pipe end configurations for different
end-uses
A.6 Notes on test procedure
A.7 Notes on test criteria
A.8 Notes on validity of test results
A.9 Notes on test report
A.10 Small diameter control cables
Annex B (normative) Standard configuration for cable penetration
seals
B.1 Structure of specimens
B.2 Deviations from standard specimens
B.3 Field of direct application
Annex C (normative) Standard configuration and field of direct
application for penetration seals for pipes
C.1 Standard configuration for penetration seals for metal pipes
C.2 Non-standard configurations
C.3 Direct field of application
Defines a method of test and criteria for the evaluation of the ability of a penetration sealing system to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service.
DocumentType |
Standard
|
PublisherName |
Norwegian Standards (Norges Standardiseringsforbund)
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
ONORM EN 1366-3 : 2009 | Identical |
NEN EN 1366-3 : 2009 | Identical |
BS EN 1366-3:2009 | Identical |
DIN EN 1366-3:2009-07 | Identical |
NF EN 1366-3 : 2012 | Identical |
NBN EN 1366-3 : 2009 | Identical |
EN 1366-3:2009 | Identical |
UNI EN 1366-3 : 2009 | Identical |
UNE-EN 1366-3:2011 | Identical |
SN EN 1366-3 : 2009 | Identical |
I.S. EN 1366-3:2009 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.