CLINICAL THERMOMETERS - PART 5: PERFORMANCE OF INFRA-RED EAR THERMOMETERS (WITH MAXIMUM DEVICE)
01-01-2013
01-12-2013
Foreword
1 Scope
2 Normative References
3 Terms and definitions
4 Unit
5 Types of thermometers
6 Requirements
6.1 General
6.2 Range of displayed temperature
6.3 Maximum permissible error
6.4 Environmental requirements
6.5 Indicating unit
6.6 Construction
7 Test Methods
7.1 General
7.2 Sampling
7.3 Testing for compliance of the range of displayed
temperature
7.4 Testing for compliance of the maximum permissible error
within ambient operating range
7.5 Testing for compliance of maximum permissible error under
extended operating conditions
7.6 Testing for compliance of maximum permissible error under
changing environmental conditions
7.7 Testing for compliance with maximum permissible clinical
repeatability - Procedure
7.8 Testing for compliance with the effect of storage and long
term stability
7.9 Method of test for mechanical shock
7.10 Testing for compliance with the variation of the supply
voltage
7.11 Testing for compliance with cleaning and disinfection
8 Information supplied by the manufacturer
8.1 General
8.2 Marking
8.3 Instruction for use
Annex A (informative) Clinical trial to determine clinical accuracy
A.1 Introduction
A.2 Clinical accuracy
A.3 Clinical trial procedure
A.4 Clinical bias and its standard deviation
A.5 Clinical repeatability
Annex B (informative) Suggested types of testing for the requirements
of this standard
Annex C (informative) Example for a suitable design of a black body
radiator
Annex D (informative) Alternative approaches to prove compliance
with 6.3
D.1 General
D.2 Separation of the maximum permissible error for the instrument
and for the probe covers
D.3 Calculation of the error using error propagation analysis
Annex ZA (informative) Clauses of this European Standard addressing
essential requirements or other provision of EU Directives
Bibliography
Defines the metrological and technical requirements for clinical infra-red (IR) ear thermometers with maximum device for intermittent determination of human body temperature.
DocumentType |
Standard
|
PublisherName |
Norwegian Standards (Norges Standardiseringsforbund)
|
Status |
Superseded
|
Standards | Relationship |
DIN EN 12470-5:2003-09 | Identical |
BS EN 12470-5:2003 | Identical |
EN 12470-5:2003 | Identical |
I.S. EN 12470-5:2003 | Identical |
UNE-EN 12470-5:2003 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.