• There are no items in your cart

NFPA 803 : 1998

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

FIRE PROTECTION FOR LIGHT WATER NUCLEAR POWER PLANTS

Withdrawn date

06-15-2000

Superseded by

NFPA 805 : 2015

Published date

01-01-1998

Sorry this product is not available in your region.

Chapter 1 Introduction
1-1 Scope
1-2 Purpose
1-3 Equivalency Concepts
1-4 Definitions
1-5 Introduction and Special Problems Relating to
      the Protection of Light Water Nuclear Electric
      Generating Stations
1-6 Units of Measurements
Chapter 2 Functional Subdivisions of the Plant
            Layout
2-1 General
2-2 Reactor, Fuel and Auxiliary Life Safety
2-3 Cost Benefit
2-4 Fire Hazard Analysis
Chapter 3 Inventory of Flammable and Combustible
            Materials
3-1 Combustible Materials
3-2 Fire Loading
3-3 Consumable Goods
3-4 Temporary Combustible Materials
Chapter 4 Control of Combustible Material
4-1 Limiting Combustibles
4-2 Reducing Fire Loads
Chapter 5 Construction Materials and Fire
            Loading in Buildings
5-1 Use of Plastics
5-2 Classification of Construction Materials
5-3 Combustible Construction
5-4 Component Materials
5-5 Electrical Components
5-6 Roofing Materials
5-7 Transformers
5-8 Cooling Towers
Chapter 6 General Building Arrangement
6-1 General Fire Area Requirements
6-2 Specific Fire Separation Requirements
6-3 Protection of Openings in Fire Barriers
6-4 Reliability Considerations
Chapter 7 Heating, Ventilating and Air
            Conditioning
7-1 Introduction
7-2 Basic Standards
7-3 General Requirements
Chapter 8 Fire Prevention Measures
8-1 Administrative Procedures and Controls
8-2 Lightning Protection Measures for Buildings
8-3 Prevention Measures for Plant Equipment
8-4 Prevention Measures for Operation of the
      Plant
Chapter 9 Fire-Signaling Systems
9-1 Fire-Signaling Systems
9-2 Fire Detectors
9-3 Selection of Detectors
9-4 Fire-Signaling System Display and Supervision
9-5 Maintenance, Inspection and Acceptance Testing
      of Fire-Signaling Systems
9-6 Communications
Chapter 10 Fire Suppression Systems
10-1 General
10-2 Automatic Sprinkler and Water Spray Systems
10-3 Gaseous Suppression Systems
10-4 Foam Systems
10-5 Dry Chemical Systems
Chapter 11 Yard Mains and Hydrants
11-1 Hydrants
11-2 Yard Mains
11-3 Indicator Valves
11-4 Hose-Stream Protection
11-5 Hose Thread
11-6 Hose Thread Adapters
Chapter 12 Water Supply
12-1 Water Supply
12-2 Initial Construction
12-3 Water Loop Construction
12-4 Water Supply Size
12-5 Jockey Pump
12-6 Water Sources
12-7 Water Quality
12-8 Supervisory Signals
Chapter 13 Portable Fire Extinguishers and Hand
            Hose Lines
13-1 Portable and Wheeled Fire Extinguishers
13-2 Hand Hose Lines
Chapter 14 Manual Fire Fighting
14-1 Availability
14-2 Action Plan
14-3 Standard for Fire Defense Measures
14-4 Liaison with Public Fire Authorities
14-5 Regular Training and Drills
14-6 Equipment for the Plant Fire Brigade
Chapter 15 Planning and Fire Protection
15-1 Responsibility
15-2 Design Specifications
15-3 Updates
15-4 Special-Hazards Systems
15-5 Repairs and Revision Work
Chapter 16 Fire Prevention and Fire Protection
            for the Construction Site
16-1 Protection
16-2 Fire Prevention
16-3 Fire Protection
16-4 Construction Safeguards
Chapter 17 Life Safety
17-1 Life Safety Code
17-2 Occupancy Classification
Chapter 18 Referenced Publications
Appendix A Explanatory Material
Appendix B Referenced Publications
Appendix C Codes and Standards
Index

Provides firesafety guidelines for light water nuclear electric generating facilities, including operating personnel, equipment, and operations. Includes the following chapters: inventory of flammable and combustible materials; control of combustible material; fire prevention measures; fire suppression systems; yard mains and hydrants; planning and fire protection; fire prevention and fire protection for the construction site. Also gives detailed definitions.

DocumentType
Standard
PublisherName
National Fire Protection Association
Status
Withdrawn
SupersededBy

NFPA 802 : 1993 NUCLEAR RESEARCH AND PRODUCTION REACTORS
IEEE 384-2008 REDLINE IEEE Standard Criteria for Independence of Class 1E Equipment and Circuits

NFPA 50A : 1999 GASEOUS HYDROGEN SYSTEMS AT CONSUMER SITES
NFPA 91 : 2015 EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS
NFPA 256 : 2003 METHODS OF FIRE TESTS OF ROOF COVERINGS
NFPA 22 : 2013 WATER TANKS FOR PRIVATE FIRE PROTECTION
NFPA 31 : 2016 INSTALLATION OF OIL-BURNING EQUIPMENT
NFPA 241 : 2013 SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS
ASME B31.1 : 2016 POWER PIPING
NFPA 71 : 1989 INSTALLATION, MAINTENANCE, AND USE OF SIGNALING SYSTEMS FOR CENTRAL STATION SERVICE
IEEE 383-2015 IEEE Standard for Qualifying Electric Cables and Splices for Nuclear Facilities
NFPA 1963 : 2014 FIRE HOSE CONNECTIONS
NFPA 214 : 2016 WATER-COOLING TOWERS
NFPA 101 : 2018 LIFE SAFETY CODE
NFPA 90A : 2018 INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS
NFPA 80A : 2017 PROTECTION OF BUILDINGS FROM EXTERIOR FIRE EXPOSURES
NFPA 17 : 2017 DRY CHEMICAL EXTINGUISHING SYSTEMS
NFPA 255 : 2006 TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS
NFPA 12B : 1990 HALON 1211 FIRE EXTINGUISHING SYSTEMS
NFPA 85C : 1991 PREVENTION OF FURNACE EXPLOSIONS & IMPLOSIONS IN MULTIPLE BURNER BOILER FURNACES
NFPA 24 : 2016 INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES
NFPA 204M : 1991 SMOKE AND HEAT VENTING
NFPA 15 : 2017 WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION
NFPA 10 : 2018 PORTABLE FIRE EXTINGUISHERS
NFPA 8501 : 1997 SINGLE BURNER BOILER OPERATION
NFPA 72E : 1990 AUTOMATIC FIRE DETECTORS
NFPA 14 : 2016 INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
ASTM E 136 : 2016-02 TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE FURNACE AT 750 DEGREES C
NFPA 220 : 2018 TYPES OF BUILDING CONSTRUCTION
NFPA 51B : 2014 FIRE PREVENTION DURING WELDING, CUTTING, AND OTHER HOT WORK
NFPA 11 : 2016 LOW-, MEDIUM-, AND HIGH-EXPANSION FOAM
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
NFPA 12 : 2015 CARBON DIOXIDE EXTINGUISHING SYSTEMS
NFPA 600 : 2015 INDUSTRIAL FIRE BRIGADES
NFPA 251 : 2006 FIRE RESISTANCE OF BUILDING CONSTRUCTION AND MATERIALS
NFPA 72 : 2016 NATIONAL FIRE ALARM AND SIGNALING CODE
NFPA 13 : 2016 INSTALLATION OF SPRINKLER SYSTEMS
NFPA 30 : 2018 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE
UL 586:9ED 2009-08-14 High-Efficiency, Particulate, Air Filter Units
NFPA 37 : 2018 INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES
NFPA 16 : 2015 INSTALLATION OF FOAM-WATER SPRINKLER AND FOAM-WATER SPRAY SYSTEMS
NFPA 12A : 2015 HALON 1301 FIRE EXTINGUISHING SYSTEMS
NFPA 252 : 2017 STANDARD METHODS OF FIRE TESTS OF DOOR ASSEMBLIES
NFPA 20 : 2016 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION
NFPA 1981 : 2013 OPEN-CIRCUIT SELF-CONTAINED BREATHING APPARATUS (SCBA) FOR EMERGENCY SERVICES
NFPA 80 : 2016 FIRE DOORS AND OTHER OPENING PROTECTIVES
NFPA 11A : 1999 MEDIUM- AND HIGH-EXPANSION FOAM SYSTEMS
ANSI B31.7 : LATEST

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.