NFPA 72E : 1990
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
AUTOMATIC FIRE DETECTORS
07-23-2013
01-12-2013
Chapter 1 Introduction
1.1 Purpose
1.2 Scope
Chapter 2 General
2.1 General
2.2 Classification of Fire Detectors
2.3 Shapes of Ceilings
2.4 Ceiling Surfaces
2.5 Common Requirements
2.6 Installation
Chapter 3 Heat Sensing Fire Detectors
3.1 General
3.2 Operating Principles
3.3 Temperature Classification
3.4 Location
3.5 Spacing
Chapter 4 Smoke Sensing Fire Detectors
4.1 General
4.2 Principles of Detection
4.3 Classification
4.4 Location and Spacing
4.5 Heating, Ventilating, and Air Conditioning (HVAC)
4.6 Special Considerations
Chapter 5 Flame Sensing Fire Detectors
5.1 General
5.2 Operating Principles
5.3 Fire Characteristics
5.4 Spacing Considerations
5.5 Field of View Considerations
5.6 Other Considerations
Chapter 6 Gas Sensing Fire Detectors
6.1 Genreal
6.2 Operating Principles
6.3 Location and Spacing
6.4 Heating, Ventilating and Air Conditioning (HVAC)
6.5 Special Considerations
Chapter 7 Other Fire Detectors
7.1 General
7.2 Fire Characteristics
7.3 Location and Spacing
7.4 Special Considerations
Chapter 8 Inspections, Tests, and Maintenance
8.1 General
8.2 Initial Installation Inspection Tests
8.3 Periodic Inspection and Tests
8.4 Cleaning and Maintenance
8.5 Tests Following an Alarm or Fire
8.6 Inspection Forms
Chapter 9 Smoke Detectors for Control of Smoke Spread
9.1 General
9.2 Purposes
9.3 Application
9.4 Location and Installation of Detectors in Air Duct
Systems
9.5 Smoke Detectors for Door Release Service
Chapter 10 Referenced Publications
Appendix A
Appendix B Spacing and Sensitivity
Appendix C Guide for Automatic Fire Detector Spacing
Index
Covers the minimum performance, location, mounting, testing, and maintenance requirements of automatic fire detectors.
DocumentType |
Standard
|
PublisherName |
National Fire Protection Association
|
Status |
Superseded
|
SupersededBy |
ASTM F 1198 : 1992 : R1997 | Standard Guide for Shipboard Fire Detection Systems |
NFPA 61B : 1989 | PREVENTION OF FIRES AND EXPLOSIONS IN GRAIN ELEVATORS AND FACILITIES HANDLING BULK RAW AGRICULTURAL COMMODITIES |
ANS 57.9-1992(R2000) | DESIGN CRITERIA FOR AN INDEPENDENT SPENT FUEL STORAGE INSTALLATION (DRY TYPE) |
NFPA 72G : 1989 | INSTALLATION, MAINTENANCE, AND USE OF NOTIFICATION APPLIANCES FOR PROTECTIVE SIGNALING SYSTEMS |
NFPA 903 : 1996 | FIRE REPORTING PROPERTY SURVEY GUIDE |
NFPA 913 : 1992 | HISTORIC SITES AND STRUCTURES |
NFPA 72B : 1986 | INSTALLATION, MAINTENANCE, AND USE OF AUXILIARY PROTECTIVE SIGNALING SYSTEMS |
NFPA 71 : 1989 | INSTALLATION, MAINTENANCE, AND USE OF SIGNALING SYSTEMS FOR CENTRAL STATION SERVICE |
NFPA 101M : 1992 | ALTERNATIVE APPROACHES TO LIFE SAFETY |
NFPA 231E : 1996 | STORAGE OF BALED COTTON |
ASTM F 1198 : 1992 : R2007 | Standard Guide for Shipboard Fire Detection Systems |
NFPA 803 : 1998 | FIRE PROTECTION FOR LIGHT WATER NUCLEAR POWER PLANTS |
ANSI N665 : 1985 | FIRE PROTECTION FOR LWR FUEL FABRICATION FACILITIES, |
API 11PGT : 1992 | RECOMMENDED PRACTICE FOR PACKAGED COMBUSTION GAS TURBINES |
AFGS-87241 Revision A:1989 | SIMULATORS, FLIGHT |
ASTM F 1198 : 1992 : R2002 | Standard Guide for Shipboard Fire Detection Systems |
NFPA 72A : 1987 | INSTALLATION, MAINTENANCE, AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS |
ANSI A225.1 : 1987 | MANUFACTURED HOME INSTALLATIONS |
NFPA 72C : 1986 | INSTALLATION, MAINTENANCE, AND USE OF REMOTE STATION PROTECTIVE SIGNALING SYSTEMS |
NFPA 72H : 1988 | TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS |
NFPA 232AM : 1991 | FIRE PROTECTION FOR ARCHIVES AND RECORDS CENTERS |
NFPA 19911 : 1991 | FIRE PROTECTION OF MUSEUMS AND MUSEUM COLLECTIONS |
NFPA 12B : 1990 | HALON 1211 FIRE EXTINGUISHING SYSTEMS |
ANSI N304 : 1986 | NUCLEAR FUEL FACILITIES FOR REPROCESSING FUEL-FIRE PROTECTION, |
NFPA 72D : 1986 | INSTALLATION, MAINTENANCE, AND USE OF PROPRIETARY PROTECTIVE SIGNALING SYSTEMS |
ANS 54.8-1988 | LIQUID METAL FIRE PROTECTION IN LMR PLANTS |
NFPA 903M : 1986 | FIRE REPORTING PROPERTY SURVEY MANUAL |
NFPA 72F : 1985 | INSTALLATION, MAINTENANCE, AND USE OF EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS |
NFPA 81 : 1986 | FUR STORAGE, FUMIGATION AND CLEANING |
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
ASTM F 1198 : 1992 : R2012 : EDT 1 | Standard Guide for Shipboard Fire Detection Systems |
NFPA 61D : 1989 | PREVENTION OF FIRE AND DUST EXPLOSIONS IN THE MILLING OF AGRICULTURAL COMMODITIES FOR HUMAN CONSUMPTION |
NFPA 61A : 1989 | PREVENTION OF FIRE AND DUST EXPLOSIONS IN FACILITIES MANUFACTURING AND HANDLING STARCH |
NFPA 61C : 1989 | PREVENTION OF FIRE AND DUST EXPLOSION IN FEED MILLS |
NFPA 74 : 1989 | HOUSEHOLD FIRE WARNING EQUIPMENT |
NFPA 72:2022 | National Fire Alarm and Signaling Code |
NFPA 71 : 1989 | INSTALLATION, MAINTENANCE, AND USE OF SIGNALING SYSTEMS FOR CENTRAL STATION SERVICE |
NFPA 101 : 2018 | LIFE SAFETY CODE |
NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
NFPA 74 : 1989 | HOUSEHOLD FIRE WARNING EQUIPMENT |
NFPA 231C : 1998 | RACK STORAGE OF MATERIALS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
NFPA 72 : 2016 | NATIONAL FIRE ALARM AND SIGNALING CODE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.