NF EN 61071 : 2007
Current
The latest, up-to-date edition.
CAPACITORS FOR POWER ELECTRONICS
01-12-2013
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
4.1 Normal service conditions
4.2 Unusual service conditions
5 Quality requirements and tests
5.1 Test requirements
5.2 Classification of tests
5.3 Capacitance and tan delta measurements (routine test)
5.4 Measurement of the tangent of the loss angle (tan delta)
of a capacitor (type test)
5.5 Voltage test between terminals
5.6 AC voltage test between terminals and case
5.7 Test of internal discharge device
5.8 Sealing test
5.9 Surge discharge test
5.10 Thermal stability test
5.11 Self-healing test
5.12 Resonance frequency measurement
5.13 Environmental testing
5.14 Mechanical testing
5.15 Endurance test
5.16 Destruction test
5.17 Disconnecting test on internal fuses
6 Overloads
6.1 Maximum permissible voltages
7 Safety requirements
7.1 Discharge device
7.2 Case connections
7.3 Protection of the environment
7.4 Other safety requirements
8 Markings
8.1 Marking of the units
9 Guide to installation and operation
9.1 General
9.2 Choice of rated voltage
9.3 Operating temperature
9.4 Special service conditions
9.5 Overvoltages
9.6 Overcurrents
9.7 Switching and protective devices
9.8 Choice of creepage distance and clearance
9.9 Connections
9.10 Parallel connections of capacitors
9.11 Series connections of capacitors
9.12 Magnetic losses and eddy currents
9.13 Guide for internal fuse and disconnector protection in
capacitors
9.14 Guide for unprotected capacitors
Annex A (informative) - Waveforms
Annex B (normative) - Operational limits of capacitors with
sinusoidal voltages as a function of frequency and
at maximum temperature (theta[max])
Annex C (normative) - Resonance frequency measuring methods -
Examples
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
Defines an extremely wide range of capacitor technologies for numerous applications, e.g. overvoltage protection, d.c. and a.c. filtering, switching circuits, d.c. energy storage, auxiliary inverters, etc. Applies to capacitors for power electronics applications.
DevelopmentNote |
Indice de classement: C54-105PR. PR NF EN 61071 April 2006. (04/2006) Supersedes NF EN 61071-1 & NF EN 61071-2. (07/2015) PR NF EN 61071 November 2016. (01/2017)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Current
|
Standards | Relationship |
IEC 61071:2017 | Identical |
UNE-EN 61071:2007 | Identical |
DIN EN 61071 : 2008 | Identical |
EN 61071:2007 | Identical |
NBN EN 61071 : 2007 | Identical |
BS EN 61071:2007 | Identical |
I.S. EN 61071:2007 | Identical |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
NF EN 60071-1 : 2006 AMD 1 2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
NF EN 60664-1 : 2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
NF EN 60947-1 : 2007 AMD 2 2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
NF EN 60071-2 : 1997 | INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
NF EN 60269-1 : 2007 AMD 2 2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
NF EN 60068 2-14 : 2009 | ENVIRONMENTAL TESTING - PART 2-14: TESTS - TEST N: CHANGE OF TEMPERATURE |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
NFC 20 720 : 87 AMD 1 1988 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST METHODS - TEST T - SOLDERING |
NF EN 60068 2-6 : 2008 | ENVIRONMENTAL TESTING - PART 2-6: TESTS - TEST FC: VIBRATION (SINUSOIDAL) |
NF EN 60068-2-78 : 2013 | ENVIRONMENTAL TESTING - PART 2-78: TESTS - TEST CAB: DAMP HEAT, STEADY STATE |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
NF EN 60695-2-11 : 2014 | FIRE HAZARD TESTING - PART 2-11: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY TEST METHOD FOR END-PRODUCTS (GWEPT) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
NF EN 60068-2-21 : 2013 | ENVIRONMENTAL TESTING - PART 2-21: TESTS - TEST U: ROBUSTNESS OF TERMINATIONS AND INTEGRAL MOUNTING DEVICES |
NF EN 60695-2-12 : 2011 AMD 1 2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.