NF EN 60601-2-40 : 2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-40: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ELECTROMYOGRAPHS AND EVOKED RESPONSE EQUIPMENTS
07-23-2019
01-12-2013
AVANT-PROPOS
INTRODUCTION
SECTION UN : GÉNÉRALITÉS
1 Domaine d'application et objet
2 Terminologie et définitions
5 Classification
6 Identification, marquage et documentation
7 Puissance absorbée
SECTION DEUX : CONDITIONS D'ENVIRONNEMENT
SECTION TROIS : PROTECTION CONTRE LES RISQUES DE CHOCS
ÉLECTRIQUES
14 Prescriptions relatives à la classification
20 Tension de tenue
SECTION QUATRE : PROTECTION CONTRE LES RISQUES MÉCANIQUES
SECTION CINQ : PROTECTION CONTRE LES RISQUES DUS AUX
RAYONNEMENTS NON DÉSIRÉS OU EXCESSIFS
36 Compatibilité électromagnétique
SECTION SIX : PROTECTION CONTRE LES RISQUES D'IGNITION
DE MÉLANGES ANESTHÉSIQUES INFLAMMABLES
SECTION SEPT : PROTECTION CONTRE LES TEMPÉRATURES
EXCESSIVES ET LES AUTRES RISQUES
42 Températures excessives
46 Erreurs humaines
SECTION HUIT : PRÉCISION DES CARACTÉRISTIQUES DE
FONCTIONNEMENT ET PROTECTION CONTRE LES
CARACTÉRISTIQUES DE SORTIE PRÉSENTANT
DES RISQUES
50 Précision des caractéristiques de fonctionnement
51 Protection contre les caractéristiques de sortie
présentant des risques
SECTION NEUF : FONCTIONNEMENT ANORMAL ET CONDITIONS
DE DÉFAUT; ESSAIS D'ENVIRONNEMENT
SECTION DIX : REGLES DE CONSTRUCTION
Annexes
L Références - Publications mentionnées dans la
présente Norme
AA (informative) - Guide général et justifications
ZA Références normatives à d'autres publications
internationales avec les publications européennes
correspondantes
ZB Autres publications internationales citées dans
la présente norme avec les références des publications
européennes correspondantes
Applicable to electromyographs as specified in 2.1.101 and evoked response equipment as defined in 2.1.102.
DevelopmentNote |
Indice de classement: C74-393. Supersedes NFC 74 393. (03/2000)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 60601-2-40 : 1998 | Identical |
IEC 60601-2-40:2016 | Identical |
I.S. EN 60601-2-40:1999 | Identical |
BS EN 60601-2-40:1998 | Identical |
EN 60601-2-40:1998 | Identical |
DIN EN 60601-2-40 : 1998 | Identical |
UNE-EN 60601-2-40:1999 | Identical |
IEC 60645-3:2007 | Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
NF EN 60601-1-2 : 2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
NF EN 60825-1 : 2014 | SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS |
IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
NF EN 60601-1-1 : 2001 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-1: GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD: SAFETY REQUIREMENTS FOR MEDICAL ELECTRICAL SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.