NF EN 60079-19 : 2011 AMD 1 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
EXPLOSIVE ATMOSPHERES - PART 19: EQUIPMENT REPAIR, OVERHAUL AND RECLAMATION
10-28-2021
01-12-2013
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
4.1 General principles
4.2 Statutory requirements
4.3 Instructions for the user
4.4 Instructions for the repair facility
5 Additional requirements for the repair and overhaul of equipment
with type of protection 'd' (flameproof)
5.1 Application
5.2 Repair and overhaul
5.3 Reclamation
5.4 Modifications
6 Additional requirements for the repair and overhaul of equipment
with type of protection 'i' (intrinsic safety)
6.1 Application
6.2 Repair and overhaul
6.3 Reclamation
6.4 Modifications
7 Additional requirements for the repair and overhaul of equipment
with type of protection 'p' (pressurized)
7.1 Application
7.2 Repair and overhaul
7.3 Reclamation
7.4 Modifications
8 Additional requirements for the repair and overhaul of equipment
with type of protection 'e' (increased safety)
8.1 Application
8.2 Repair and overhaul
8.3 Reclamation
8.4 Modifications
9 Additional requirements for the repair and overhaul of equipment
with type of protection 'n' (non-sparking)
9.1 Application
9.2 Repair and overhaul
9.3 Reclamation
9.4 Modifications
10 Additional requirements for the repair and overhaul of equipment
covered by IEC 60079-26
11 Additional requirements for the repair and overhaul of equipment
with type of protection 'tD'
11.1 Application
11.2 Repair and overhaul
11.3 Reclamation
11.4 Modifications
12 Additional requirements for the repair and overhaul of equipment
with type of protection pressurization 'pD'
12.1 Application
12.2 Repair and overhaul
12.3 Reclamation
12.4 Modifications
Annex A (normative) Identification of repaired equipment by marking
Annex B (normative) Knowledge, skills and competencies of 'Responsible
Persons' and 'Operatives'
Annex C (normative) Requirements for measurements in flameproof
equipment during overhaul, repair and reclamation
(including guidance on tolerances)
Annex ZA (normative) Normative references to international
publications with their corresponding European publications
Specifies instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of a certified equipment designed for use in explosive atmospheres.
DevelopmentNote |
Indice de classement: C23-579-19. PR NF EN 60079-19 September 2005. (09/2005) PR NF EN 60079-19 October 2010. (11/2010)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NBN EN 60079-19 : 2011 AMD 1 2015 | Identical |
BS EN 60079-19 : 2011 | Identical |
I.S. EN 60079-19:2011 | Identical |
EN 60079-19:2011/A1:2015 | Identical |
DIN EN 60079-19 : 2015-09 | Identical |
IEC 60079-19:2010+AMD1:2015 CSV | Identical |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
ISO 4526:2004 | Metallic coatings Electroplated coatings of nickel for engineering purposes |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 61241-4:2001 | Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD" |
ISO 6158:2011 | Metallic and other inorganic coatings Electrodeposited coatings of chromium for engineering purposes |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.