NEN EN 13950 : 2014
Current
The latest, up-to-date edition.
GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS
01-12-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
3.1 Terms and definitions of the product
3.2 Terminology
4 Requirements
4.1 General
4.2 Fire behaviour
4.2.1 Reaction to fire
4.2.2 Fire resistance
4.3 Water vapour permeability (expressed as water vapour
resistance factor)
4.4 Flexural strength
4.5 Impact resistance
4.6 Direct airborne sound insulation
4.7 Acoustic absorption
4.8 Thermal resistance of the panel
4.9 Dimensions and tolerances
4.10 Offset
4.11 Flatness of the composite
4.12 Adhesion/cohesion of the insulating material
4.13 Dangerous substances
5 Test methods
5.1 Sampling
5.2 Dimensional measurements
5.2.1 Width
5.2.2 Length
5.2.3 Thickness
5.3 Determination of the offset
5.3.1 Principle
5.3.2 Apparatus
5.3.3 Procedure
5.3.4 Expression of results
5.4 Determination of the flatness of the composite
5.4.1 Principle
5.4.2 Apparatus and specimens
5.4.3 Procedure
5.4.4 Expression of results
5.5 Determination of the adhesion/cohesion of the
insulating material
5.5.1 Principle
5.5.2 Apparatus
5.5.3 Procedure
5.5.4 Expression of results
6 Evaluation of conformity
6.1 General
6.2 Type testing
6.2.1 General
6.2.2 Initial type testing
6.2.3 Further type testing
6.3 Factory production control (FPC)
6.3.1 General
6.3.2 Personnel
6.3.3 Equipment
6.3.4 Raw materials and components
6.3.5 Product testing and evaluation
6.3.6 Traceability and marking
6.3.7 Non-conforming products
6.3.8 Corrective action
6.3.9 Other test methods
7 Designation of composite panels
8 Marking, labelling and packaging
Annex A (informative) Sampling procedure for testing
A.1 General
A.2 Sampling procedure
A.2.1 Random sampling
A.2.2 Representative sampling
Annex B (normative) Mounting and fixing in the test according
to EN 13823 (SBI test)
B.1 Mounting and fixing of the composite panels
Annex ZA (informative) Clauses of this European Standard
addressing provisions of EU Construction Products
Directive
ZA.1 Scope and relevant characteristics
ZA.2 Attestation and declaration of conformity of gypsum
plasterboard thermal/acoustic insulation composite
panels
ZA.3 CE marking and labelling
Bibliography
Defines the characteristics and performance of thermal/acoustic insulation composite panels made of an insulating material laminated to gypsum boards for which the main intended use is the internal insulation (thermal and/or acoustic) of walls.
DocumentType |
Standard
|
PublisherName |
Netherlands Standards
|
Status |
Current
|
Standards | Relationship |
DIN EN 13950:2014-09 | Identical |
EN 13950:2014 | Identical |
UNE-EN 13950:2006 | Identical |
BS EN 13950:2014 | Identical |
UNI EN 13950 : 2014 | Identical |
I.S. EN 13950:2014 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.