NEN EN 13384-2 : 2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 2: CHIMNEYS SERVING MORE THAN ONE HEATING APPLIANCE
07-01-2019
01-12-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
3.1 chimney segment
3.2 collector segment
3.3 air-flue gas system
3.4 flue gas mass flow (m)
3.5 calculated flue gas temperature (T[Wc,j])
3.6 calculated draught of the flue gas of the heating
appliance (P[Wc,j])
3.7 flue damper
3.8 balanced flue chimney
3.9 cascade arrangement
3.10 multi inlet arrangement
3.11 air duct
3.12 pressure equalising opening
4 Symbols, terminology, units
5 Calculation method
5.1 General principles
5.2 Pressure equilibrium condition
5.3 Mass flow requirement
5.4 Pressure requirement
5.5 Temperature requirement
5.6 Calculation procedure
6 Flue gas data characterising the heating appliance
7 Data for chimney and connecting flue pipes
8 Basic data for the calculation
8.1 Air temperatures
8.2 External air pressure (p[L])
8.3 Gas constant
8.4 Density of air (rho[L])
8.5 Specific heat capacity of the flue gas (c[p])
8.6 Water vapour content (sigma(H[2]O)[j]) and condensing
temperature (T[sp])
8.7 Correction factor for temperature instability (S[H])
8.8 Flow safety coefficient (S[E])
8.9 External coefficient of heat transfer
9 Determination of temperatures
10 Mixing calculations
10.1 Flue gas mass flow (m[j])
10.2 Flue gas temperature at the inlet of the chimney
segment (T[e,j])
10.3 CO[2]-content of the flue gas in the chimney segment
(sigma(CO[2])[j])
10.4 H[2]O-content of the flue gas (sigma(H[2]O)[j])
10.5 Gas constant of the flue gas (R[j])
10.6 Flue gas data
11 Density and velocity of the flue gas
12 Draught at the outlet of the connecting flue pipe and draught
at the inlet of the chimney segment
12.1 Draught at the inlet of the chimney segment
12.2 Draught required at the outlet of the connecting flue
pipe (Pz[e,j])
13 Inner wall temperature
14 Cascade installations
14.1 Principle of the calculation method
14.2 Pressure equilibrium condition
14.3 Mass flow requirement
14.4 Pressure requirement
14.5 Temperature requirement
14.6 Calculation procedure
14.7 Draught at the outlet of the connecting flue pipe
and draught at the inlet of the collector segment
14.8 Inner wall temperature (T[iobc,j,i])
15 Balanced flue chimney
15.1 Principle of the calculation method
15.2 Pressure equilibrium condition
15.3 Mass flow requirement
15.4 Pressure requirements
15.5 Temperature requirements
15.6 Calculation procedure for balanced flue chimneys
15.7 Mass flow of the supply air
15.8 Determination of the temperatures in balanced flue
chimneys
15.9 Pressure resistance of the air supply
15.10 Density and velocity of the supply air
Annex A (informative) - Recommendations
A.1 - Recommendations for the chimney and heating appliances
A.2 - Recommendations for connecting flue pipes
Annex B (informative) - Characteristics for the heating appliance
Defines methods for calculation of the thermal and fluid dynamic characteristics of chimneys serving more than one heating appliance.
DocumentType |
Standard
|
PublisherName |
Netherlands Standards
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
BS EN 13384-2 : 2003 | Identical |
DIN EN 13384-2:2015-06 | Identical |
UNE-EN 13384-2:2016 | Identical |
I.S. EN 13384-2:2015 | Identical |
NBN EN 13384-2 : 2015 | Identical |
NS EN 13384-2 : 2003 | Identical |
EN 13384-2:2015 | Identical |
ONORM EN 13384-2 : 2015 | Identical |
NF EN 13384-2 : 2015 | Identical |
SN EN 13384-2 : 2015 | Identical |
UNI EN 13384-2 : 2009 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.