NBN EN ISO 8289 : 2002
Current
The latest, up-to-date edition.
VITREOUS AND PORCELAIN ENAMELS - LOW VOLTAGE TEST FOR DETECTING AND LOCATING DEFECTS
01-12-2013
Foreword
1 Scope
2 Normative reference
3 Term and definition
4 Principle
5 Test reagent
6 Apparatus
7 Test specimen
8 Procedure
9 Expression of results
10 Test report
Defines two low voltage tests to detect and locate defects that extend to the basis metal in porcelain and vitreous porcelain enamel coatings. Method A (electrical) is suitable for rapid detection and determination of general location of defects. Method B (optical), based on colour effects, is suited to the more precise detection of defects and their exact locations. Method A is commonly applied to flat surfaces where method B is for more intricate shapes.
DocumentType |
Standard
|
PublisherName |
Belgian Standards
|
Status |
Current
|
Standards | Relationship |
I.S. EN ISO 8289:2002 | Identical |
EN ISO 8289:2001 | Identical |
NF EN ISO 8289 : 2001 | Identical |
BS EN ISO 8289:2001 | Identical |
NS EN ISO 8289 : 1ED 2001 | Identical |
UNE-EN ISO 8289:2002 | Identical |
ISO 8289:2000 | Identical |
UNI EN ISO 8289 : 2002 | Identical |
DIN EN ISO 8289:2001-12 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.