NBN EN 60269-1 : 2007 AMD 2 2014
Current
The latest, up-to-date edition.
LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
01-12-2013
Foreword
1 General
1.1 Scope and object
1.2 Normative references
2 Definitions
2.1 Fuses and their component parts
2.2 General terms
2.3 Characteristics quantities
3 Conditions for operation in service
3.1 Ambient air temperature
3.2 Altitude
3.3 Atmospheric conditions
3.4 Voltage
3.5 Current
3.6 Frequency, power factor and time constant
3.7 Conditions of installation
3.8 Utilization category
3.9 Discrimination of fuse-links
4 Classification
5 Characteristics of fuses
5.1 Summary of characteristics
5.2 Rated voltage
5.3 Rated current
5.4 Rated frequency
5.5 Rated power dissipation of a fuse-link and rated 0026
power acceptance of a fuse-holder
5.6 Limits of time-current characteristics
5.7 Breaking range and breaking capacity
5.8 Cut-off current and characteristics
6 Markings
6.1 Markings of fuse-holders
6.2 Markings of fuse-links
6.3 Marking symbols
7 Standard conditions for construction
7.1 Mechanical design
7.2 Insulation properties
7.3 Temperature rise, power dissipation of the fuse-link
and power acceptance of the fuse-holder
7.4 Operation
7.5 Breaking capacity
7.6 Cutt-off current characteristics
7.7 I(2)t characteristics
7.8 Overcurrent discrimination of use-links
7.9 Protection against electric shock
7.10 Resistance to heat
7.11 Mechanical strength
7.12 Resistance to corrosion
7.13 Resistance to abnormal heat and fire
7.14 Electromagnetic compatibility
8 Tests
8.1 General
8.2 Verification of the insulating properties
8.3 Verification of temperature rise and power dissipation
8.4 Verification of operation
8.5 Verification of the breaking capacity
8.6 Verification of the cut-off current characteristics
8.7 Verification of I(2)t characteristics and overcurrent
discrimination
8.8 Verification of the degree of protection of enclosures
8.9 Verification of resistance to heat
8.10 Verification of non-deterioration of contacts
8.11 Mechanical and miscellaneous tests
Annex A (informative) Measurement of short-circuit power factor 006
Annex B (informative) Calculation of pre-arcing I(2)t values
for 'gG', 'gM', 'gD' and 'gN' fuse-links
Annex C (informative) Calculation of cut-off current-time
characteristics
Annex D (informative) Effect of change of ambient temperature
or surroundings on the performance of fuse-links
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Applies to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 kA, intended for protecting power-frequency a.c. circuits of nominal voltages not exceeding 1 000 V or d.c. circuits of nominal voltages not exceeding 1 500 V.
DevelopmentNote |
Supersedes NBN EN 60269-2 and NBN EN 60269-3. (12/2007)
|
DocumentType |
Standard
|
PublisherName |
Belgian Standards
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS EN 60269-1 : 2007 | Identical |
NF EN 60269-1 : 2007 AMD 2 2014 | Identical |
EN 60269-1:2007/A2:2014 | Identical |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Identical |
I.S. EN 60269-1:2007 | Identical |
SN EN 60269-1 : 1998 | Identical |
DIN EN 60269-1 : 2015 | Identical |
UNE-EN 60269-1:2008 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.