MIL-STD-1474 Revision E:2015
Current
The latest, up-to-date edition.

Noise Limits
English
04-15-2015
1. Introduction
2. Applicable Documents
3. Definitions
4. General Requirements
5. Detailed Requirements
6. Notes
Appendix A - Steady-state noise requirements for
personnel-occupied areas
Appendix B - Impulsive noise requirements for
personnel-occupied areas
Appendix C - Aural non-detectability requirements
Appendix D - Aircraft noise requirements
Appendix E - Shipboard equipment noise requirements
Appendix F - Shipboard compartment noise requirements
CONCLUDING MATERIAL
Sets up acoustic noise limits and prescribes testing requirements and measurement procedures for determining conformance to the noise limits stated herein.
DevelopmentNote |
Supersedes MIL STD 1789. (03/2004) Supersedes MIL STD 740 (B). (04/2012) Supersedes MIL STD 740-1. (10/2012)
|
DocumentType |
Standard
|
Pages |
124
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
This standard establishes acoustic noise limits and prescribes testing requirements and measurement procedures for determining conformance to the noise limits stated herein. The standard specifies sound pressure level limits and measurement procedures to promote personnel safety, speech intelligibility, and security from acoustic detection and recognition. Acoustical noise limits for determining conformance to community annoyance requirements are beyond the scope of this standard. Noise limits for community annoyance are covered by local laws and statutes. DoD materiel (motor vehicles, construction and material handling equipment, mobile generator sets, and portable air compressors)may have to comply with these local laws and statutes anywhere in the world they operate.
DEFSTAN 00-250(PT3)SEC13/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 13 - THE WORKPLACE |
MIL-R-71126 Base Document:1992 | RIFLE, 7.62 MILLIMETER, SNIPER W/DAY OPTICAL SIGHT AND CARRYING CASES - M24 |
MIL-C-62500 Base Document:1985 | CARRIER, ELECTRONIC WARFARE SYSTEM, FULL-TRACKED: M1015A1 |
MIL-C-52972 Revision A:1987 | COMPRESSOR UNIT, 5 CFM, 3200 PSI, DIESEL ENGINE DRIVEN, DIVING AIR |
MIL-A-53100 Base Document:1990 | ARCTIC FUEL SYSTEM SUPPLY POINT (AFSSP) |
MIL-L-52733 Revision A:1986 | LABORATORY, AIRMOBILE, AVIATION FUEL |
MIL-C-52326 Revision B:1974 | CRANE, CRAWLER MOUNTED, 60 TON AT 25 FOOT RADIUS, DIESEL ENGINE DRIVEN |
MIL-A-26846 Revision B:1984 | AIR CONDITIONER, A/M32C-4, TRAILER MOUNTED, VAPOR CYCLE, ELECTRIC, MOTOR DRIVEN |
MIL-L-53106 Base Document:1990 | LAUNCHER, BRIDGE, LIGHT ASSAULT TOWED |
MIL-B-734 Revision E:1984 | BREAKER, PAVING, GASOLINE POWERED, SELF CONTAINED |
MIL-PRF-32316 Base Document:2008 | RIFLE, 7.62 MM: SEMI-AUTOMATIC SNIPER SYSTEM (SASS) - M110 |
MIL-STD-1908 Base Document:1992 | DEFINITION OF HUMAN FACTOR TERMS (METRIC) |
MIL-P-53124 Base Document:1992 | POWER UNITS/POWER PLANTS, ELECTRIC, DIESEL ENGINE, TRAILER MOUNTED |
MIL-HDBK-1908 Revision B:1999 | Definitions of Human Factors Terms |
MIL-HDBK-705 Revision C:1987 | GENERATOR SETS, ELECTRICAL, MEASUREMENTS AND INSTRUMENTATIONS |
MIL-C-52980 Revision B:1988 | COMPRESSOR, RECIPROCATING AND ROTARY, GASOLINE ENGINE DRIVEN, AIR |
MIL-DTL-32529 Base Document:2015 | POWER ELECTRONIC CONVERSION EQUIPMENT, NAVAL SHIPBOARD |
DEFSTAN 00-250(PT3)SEC12/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 12 - OPERATIONS, MAINTENANCE & SUPPORT |
MIL-PRF-32272 Revision A:2016 | INTEGRATED POWER MANAGEMENT CENTER (IPMC) |
MIL-C-555 Revision L:1991 | COMPRESSOR, AIR RECIPROCATING AND ROTARY, DIESEL ENGINE DRIVEN |
MIL-DTL-17060 Revision G:2009 | MOTORS, ALTERNATING CURRENT, INTEGRAL-HORSEPOWER, SHIPBOARD USE |
DEFSTAN 00-25(PT20)/1(2004) : 2004 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 20: HEALTH HAZARD ASSESSMENT DOMAIN |
MIL-D-70789 Revision A:1992 | DYNAMIC REFERENCE UNIT (DRU) |
MIL-PRF-32327 Base Document:2009 | Rifle, Caliber .50:Sniper W/Day Optic Sight and Carrying Cases - M107 |
MIL-B-385 Revision G:1985 | BREAKERS, PAVING, PNEUMATIC-POWERED (7/8-INCH HEXAGON BY 2-3/4-INCH CHUCK AND 7/8-INCH HEXAGON BY 3-1/4-INCH CHUCK) |
SAE J2531_201604 | Impulse Noise from Automotive Inflatable Devices |
MIL-P-53125 Base Document:1992 | POWER PLANTS, ELECTRIC, DIESEL ENGINE, TRAILER MOUNTED, GENERAL SPECIFICATION FOR |
MIL-PRF-30099 Revision A:2011 | TREATMENT SYSTEM, BLACKWATER AND COMBINED BLACKWATER/GRAYWATER, FOR SURFACE SHIPS |
MIL-A-52963 Revision B:1986 | AIR CONDITIONER: SPLIT-PACKAGE, 208-VOLT, 3-PHASE, 400-HERTZ, AC, 18,000 BTU/HR COOLING, 30,000 BTU/HR HEATING |
DEFSTAN 00-970(PT0)/9(2012) : 2012 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
MIL-DTL-24151 Revision B:2016 | DOORS, ROLLER CURTAIN AND HINGED SLAT, AND ASSOCIATED OPERATING EQUIPMENT |
MIL-PRF-32150 Revision B:2013 | STATIC AUTOMATIC BUS TRANSFER SWITCH (SABT) ON SURFACE AND SUBMARINE NAVAL VESSELS |
MIL-PRF-17773 Revision D:2015 | SWITCH, BUS TRANSFER, ELECTRIC POWER, AUTOMATIC |
MIL-A-52767 Revision D:1989 | AIR CONDITIONER: VERTICAL AND HORIZONTAL, COMPACT |
MIL-P-52327 Revision C:1990 | PUMPS, CENTRIFUGAL, ELECTRIC-MOTOR-DRIVEN, POSITIVE PRIME, PETROLEUM PRODUCTS, AIRFIELD DEFUELLING AND RECEIVING |
MIL-C-13874 Revision K:1992 | COMPRESSORS, RECIPROCATING AND ROTARY, AIR, ELECTRIC MOTOR DRIVEN |
DEFSTAN 00-970(PT0)/17(2016) : 2016 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
DEFSTAN 00-970(PT0)/14(2014) : 2014 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
MIL-DTL-32483 Base Document:2013 | Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard |
DEFSTAN 00-970(PT0)/7(2011) : 2011 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
MIL-P-53065 Base Document:1986 | PUMPING UNIT, FRAME MOUNTED, 1-1/2 INCH, ELECTRIC MOTOR DRIVEN, 35 GPM AT 25 FEET TOTAL HEAD |
MIL-STD-1365 Revision C:2010 | GENERAL DESIGN CRITERIA FOR HANDLING EQUIPMENT ASSOCIATED WITH WEAPONS AND RELATED ITEMS |
MIL-STD-2148 Revision A:2016 | Vibration Damping Materials, Procedures for Installation, Maintenance, and Repairs |
MIL-DTL-3124 Revision E:2014 | GENERATOR, ALTERNATING CURRENT, 60-HERTZ (NAVAL SHIPBOARD USE) |
MIL-PRF-32017 Base Document:1997 | REFRIGERATION SYSTEM, ADVANCED DESIGN |
MIL-A-0052767 Revision E:1994 | AIR CONDITIONERS: VERTICAL AND HORIZONTAL, COMPACT |
DEFSTAN 00-970(PT0)/11(2013) : 2013 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
DEFSTAN 00-970(PT0)/15(2015) : 2015 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
DEFSTAN 00-970(PT0)/12(2014) : 2014 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
DEFSTAN 00-970(PT0)/13(2014) : 2014 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
MIL-C-52788 Revision B:1992 | CONTAINER, REFRIGERATED: 8 FEET X 8 FEET X 20 FEET, INSULATED |
MIL-PRF-43891 Revision C:1997 | REFRIGERATION UNITS, ELECTRIC, 9000 BTU FOR MILITARY VAN CONTAINER, REFRIGERATED, INSULATED |
DEFSTAN 00-970(PT0)/8(2011) : 2011 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
MIL-PRF-32335 Base Document:2010 | TRICON REFRIGERATED CONTAINER SYSTEM (TRCS) |
SAE AS 6228 : 2014 | SAFETY REQUIREMENTS FOR PROCUREMENT, MAINTENANCE AND USE OF HAND-HELD POWERED TOOLS |
MIL-C-11085 Revision D:1986 | CONVEYOR, BELT; (FLAT, SKID-MOUNTED, ELECTRIC-MOTOR-DRIVEN, 24-INCH-WIDE BELT, 50-FOOT-LONG FRAME; CAPACITY, 25 POUNDS PER FOOT, 75 TONS PER HOUR) |
DEFSTAN 00-970(PT0)/10(2013) : 2013 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
DEFSTAN 00-970(PT0)/16(2015) : 2015 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 0: PROCEDURES FOR USE, CONTENT AND DEFINITIONS |
DEFSTAN 00-250(PT2)/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 2: PARTICULAR PEOPLE-RELATED REQUIREMENTS |
MIL-P-52632 Revision D:1976 | POWER PLANT, UTILITY:MUST HOSPITAL SYSTEM |
MIL-C-0052980 Revision C:1994 | COMPRESSORS, RECIPROCATING AND ROTARY, AIR DIESEL-ENGINE-DRIVEN, OR GASOLINE-ENGINE-DRIVEN |
MIL-H-4607 Revision E:1987 | HEATER, ENGINE AND SHELTER, GROUND |
MIL-B-53107 Base Document:1990 | BRIDGE, LIGHT ASSAULT 23 METER SPAN |
MIL-T-52942 Revision C:1996 | TRUCK, FIRE FIGHTING: PUMPER, 1000 GPM; LADDER/WATER TOWER COMBINATION |
DEFSTAN 00-250(PT3)SEC1-7/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTIONS 1-7 - OVERALL CONTENTS/SCOPE |
DEFSTAN 00-250(PT4)/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 4: HFI METHOD, TOOLS AND TECHNIQUES |
DEFSTAN 00-250(PT3)SEC8/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 8 - PEOPLE IN SYSTEMS |
MIL-C-13899 Revision F:1985 | COMPRESSOR UNIT, ROTARY: AIR, WHEELBARROW-FRAME-MOUNTED, TWO PNEUMATIC TIRES, GASOLINE-ENGINE-DRIVEN, 60-CFM, 6.5-PSIG |
DEFSTAN 61-23 SUPP001/1(2011) : 2011 | GENERIC FUEL CELL - SUPPLEMENT 1: METHANOL FUEL CELL SYSTEM |
DEFSTAN 00-27/3(2015) : 2015 | THE MEASUREMENT OF IMPULSE NOISE FROM MILITARY WEAPONS, EXPLOSIVES AND PYROTECHNICS; AND SELECTION OF HEARING PROTECTION |
MIL-STD-705 Revision D:2016 | MOBILE ELECTRIC POWER SYSTEMS |
MIL-DTL-16377 Revision J:2014 | Fixtures, Lighting; and Associated Parts; Shipboard Use, General Specification for |
MIL-PRF-53024 Revision C:2012 | COMPACTOR, HIGH SPEED, SELF-PROPELLED, COMMERCIAL CONSTRUCTION EQUIPMENT (CCE) |
MIL-A-26624 Revision B:1981 | AIR CONDITIONER, A/M32C-5, TRAILER MOUNTED, VAPOR CYCLE, ELECTRIC MOTOR DRIVEN |
MIL-C-52648 Revision D:1993 | CRANE, CRAWLER MOUNTED, 40 TON AT 12 FOOT RADIUS, 2 CUBIC YARD, DIESEL-ENGINE DRIVEN |
MIL-P-10360 Revision G:1993 | PUMP, CENTRIFUGAL 4 INCH AND 6 INCH, GASOLINE ENGINE AND DIESEL ENGINE DRIVEN FOR WATER |
MIL-T-62514 Base Document:1985 | TRUCK, 5 TON, 6X6, M939A1 SERIES |
MIL-DTL-38195 Revision D:2000 | Generator Set, Gas Turbine Engine, 60 KW 400 Hertz, General Purpose |
MIL-DTL-32572 Base Document:2017 | Anchor Windlass, Electro-Mechanical, Vertical, Two-Speedand Variable-Speed |
MIL P 52955 : A | POSITION & AZIMUTH DETERMINING SYSTEM (PADS), AN/USQ-70(U) |
MIL-S-8512 Revision D:1974 | SUPPORT EQUIPMENT AERONAUTICAL, SPECIAL, GENERAL SPECIFICATION FOR THE DESIGN OF |
NASA STD 3001 VOL 2 : 2015 | NASA SPACE FLIGHT HUMAN-SYSTEM STANDARD - VOLUME 2: HUMAN FACTORS, HABITABILITY, AND ENVIRONMENTAL HEALTH |
MIL S 45154 : J NOTICE 1 | SEMITRAILERS, REFUSE COLLECTION, COMPACTION TYPE: COMMERCIAL |
MIL-B-12570 Revision D:1977 | BAKERY OVEN, TRAILER MOUNTED, M-533 |
MIL-PRF-24775 Revision A:2005 | Air Conditioning Fan Coil Units, Horizontal and Vertical Types, Naval Shipboard |
DEFSTAN 00-250(PT3)SEC14/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 14 - THE ENVIRONMENT |
MIL-DTL-32408 Base Document:2012 | INTEGRAL MOTOR PUMP (IMP) |
MIL-H-11511 Revision G:1980 | HEATER, SPACE, MULTIFUEL, WITH BLOWER 60,000 BTU/HR |
MIL-A-11210 Revision G:1981 | AIR CONDITIONERS: BASE MOUNTED, SELF-CONTAINED, MULTIPACKAGE-TYPE, AIR-COOLED, ELECTRIC-MOTOR-DRIVEN, 18,000 - BTU/HR |
DEFSTAN 00-250(PT3)SEC10/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 10 - SYSTEMS SAFETY |
MIL-C-52037 Revision F:1990 | COMPRESSOR UNIT, RECIPROCATING, POWER DRIVEN, AIR, 15 CFM 3,500 PSI |
DEFSTAN 00-250(PT3)SEC11/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 11 - TRAINING |
SAE J1775_201505 | Bleed-Air Pneumatic Systems for Gas Turbine Equipped Marine and Amphibious Craft |
SAE AIR 1826 : 2016 | ACOUSTICAL CONSIDERATIONS FOR AIRCRAFT ENVIRONMENTAL CONTROL SYSTEM DESIGN |
MIL-PRF-32168 Base Document:2004 | VARIABLE SPEED DRIVE SYSTEM FOR INDUCTION AND SYNCHRONOUS MACHINES |
MIL-HDBK-115 Revision C:2016 | U.S. ARMY REVERSE ENGINEERING HANDBOOK (GUIDELINES AND PROCEDURES) |
MIL-P-53087 Base Document:1989 | POWER PLANT, ELECTRIC, DIESEL ENGINE-DRIVE, TRAILER MOUNTED, 3KW, 60 HERTZ, AN/MJQ-32 |
MIL-STD-1472 Revision G:2012 | HUMAN ENGINEERING |
MIL-HDBK-516 Revision C:2014 | AIRWORTHINESS CERTIFICATION CRITERIA |
MIL-A-52435 Revision D:1984 | AIR CONDITIONER: BASE MOUNTED, AIR-COOLED, 208-VOLT, 3-PHASE, 50- AND 60-HERTZ AC, SINGLE- PACKAGE, 36,000 BTU/HR |
MIL-HDBK-759 Revision C:1995 | HANDBOOK FOR HUMAN ENGINEERING DESIGN GUIDELINES |
MIL-E-87235 Base Document:1985 | EMERGENCY ESCAPE, AIRCRAFT (REQUEST FOR ISSUE MUST BE SENT VIA ASD/ENES, WRIGHT-PATTERSON AFB OH 45433-6503 |
DEFSTAN 00-250(PT0)/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 0: HUMAN FACTORS INTEGRATION |
MIL-P-52405 Revision C:1990 | PUMPS, CENTRIFUGAL, ELECTRIC-MOTOR-DRIVEN (FOR WATER) |
MIL-STD-398 Revision A:2014 | Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance |
MIL-S-18471 Revision G:1983 | System, Aircrew Automated Escape, Ejection Seat Type, General Specification For |
MIL-C-52973 Revision A:1987 | COMPRESSOR UNIT, 20 CFM, 5000 PSI, DIESEL-ENGINE-DRIVEN DIVING AIR |
SAE J1776_201402 | Marine Vehicles - Hydraulic System Pumps and Motors - Design and Specification Guide |
MIL-B-467 Revision E:1988 | BREAKER, PAVING: PNEUMATIC |
MIL-C-62310 Revision A:1982 | CARRIER, ARMORED, FULL TRACKED, M113A2, M106A2, M125A2, & M577A2 AND CHASSIS, WEAPON, FULL TRACKED, M741A1, AND M901 |
KKK-S-2851 Base Document:1994 | SEMITRAILERS, REFUSE COLLECTION, COMPACTION TYPE: COMMERCIAL |
MIL-C-62747 Base Document:1994 | CARRIER-CARGO, TRACKED, 6 TON-M548A3 |
MIL-W-52482 Revision D:1978 | WATER PURIFICATION UNIT, ELECTRIC MOTOR DRIVEN ERDLATOR TYPE CLARIFIER, DIATOMITE TYPE FILTER, VAN BODY MOUNTED 1,500 GPH |
MIL-G-52884 Revision A:1981 | GENERATOR SETS, DIESEL ENGINE DRIVEN, 15 THRU 200 KILOWATTS 50/60 & 400 HERTZ, (TACTICAL) |
MIL-P-53088 Base Document:1989 | POWER PLANT, ELECTRIC, DIESEL ENGINE DRIVEN, TRAILER MOUNTED, 3KW, 60 HERTZ |
MIL-B-10122 Revision E:1991 | BARGE, LIQUID CARGO: NONPROPELLED, STEEL, OFFSHORE, 4,160-BARREL, 120-FOOT, DESIGN 231C |
DEFSTAN 00-250(PT3)SEC15/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 15 - WORK EQUIPMENT |
NASA STD 3000 VOL 2 : 1995 | MAN-SYSTEMS INTEGRATION STANDARDS - VOLUME 2 |
IPC HDBK 630 : 0 | GUIDELINES FOR DESIGN, MANUFACTURE, INSPECTION AND TESTING OF ELECTRONIC ENCLOSURES ASSEMBLY |
GGG-L-795 Revision E:1990 | LUBRICATING UNIT, POWER OPERATED, AND PUMPING UNITS, PRESSURE LUBRICATING, DRUM MOUNTING |
MIL-P-43155 Revision F:1984 | PRINTING PLANT, SPECIAL WARFARE, TRANSPORTABLE, (LIGHTWEIGHT) MODEL 800 |
MIL B 45367 : AA NOTICE 1 | BUSES, MOTOR: TRANSIT, AMBULANCE CONVERSION, FORWARD CONTROL, WITH HIGH HEADROOM, 30 AND 44 PASSENGER, 2 WHEEL DRIVE |
DEFSTAN 00-25(PT16)/1(2004) : 2004 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 16: INTRODUCTION AND MANPOWER DOMAIN |
MIL-DTL-62270 Revision B:1998 | CHASSIS, TANK: ARMORED VEHICLE, BRIDGE LAUNCHER, M48A5 |
A-A-59918 Revision B:2014 | SELF PROPELLED CONCRETE SAW (SPCS) |
MIL-HDBK-785 Base Document:1990 | Design of Towed Artillery Weapon Systems |
MIL-L-44142 Revision A:1986 | LAUNDRY UNIT, TRAILER MOUNTED |
MIL PRF 62270 : A | CHASSIS, TANK: ARMORED VEHICLE, BRIDGE LAUNCHER, M48A5 |
SAE AS4073A | Air Cycle Air Conditioning Systems for Military Air Vehicles |
MIL-PRF-52955 Revision D:2009 | IMPROVED POSITION AND AZIMUTH DETERMINING SYSTEM (IPADS) |
MIL-G-83380 Base Document:1979 | GENERATOR SET, GAS TURBINE ENGINE DRIVEN, 30 AND 60 KW, 400 HZ |
MIL-T-52932 Revision D:1991 | TRUCK, LIFT, FORK, INTERNAL COMBUSTION ENGINE, 4000-6000 POUND CAPACITY, GENERAL SPECIFICATION FOR |
DEFSTAN 00-250(PT3)SEC16/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 16 - LIVING SPACES |
MIL-A-0083216 Revision C:1976 | AIR CONDITIONER, HORIZONTAL, 54,000 BTUH, 208/230 V |
MIL-C-52988 Revision A:1987 | CHAMBER, DECOMPRESSION, DIVERS, 100 PSI |
MIL-DTL-17840 Revision D:2018 | Pump, Centrifugal, Close-Coupled, Navy Standard (for Surface Ships Application) |
GGG-S-62 Revision D:1986 | SAW, CHAIN, PORTABLE, POWER |
MIL-P-53045 Revision A:1985 | POWER PLANT, ELECTRIC DIESEL ENGINE, TRAILER MOUNTED, 10KW, 400HERTZ, AN/MJQ-25 |
KKK-B-1579 Revision B:1985 | BUSES, MOTOR: SCHOOL, WITH HIGH HEADROOM, 20-, 28-, 36-, 44-, 58-PASSENGER, TWO-WHEEL DRIVE |
SAE J1782_201305 | Ship Systems and Equipment - Hydraulic Systems - Noise Control |
DEFSTAN 00-250(PT3)SEC9/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 3: TECHNICAL GUIDANCE - SECTION 9 - PEOPLE CHARACTERISTICS |
MIL-P-53123 Base Document:1992 | POWER UNITS/POWER PLANTS, ELECTRIC, DIESEL ENGINE, TRAILER MOUNTED, GENERAL SPECIFICATION FOR |
MIL-PRF-43001 Revision G:2016 | WASHER-EXTRACTORS, LAUNDRY, COMMERCIAL |
MIL-H-11689 Revision C:1974 | HAMMER, PNEUMATIC, PORTABLE, NAIL-DRIVING |
MIL-S-49038 Base Document:1974 | SHELTER, ELECTRICAL EQUIPMENT S-541()/TTC-38(V) |
MIL-L-52841 Revision A:1981 | LABORATORY, FIELD, TRAILER, CHASSIS MOUNTED, FOR DEVELOPING PIPELINE WELD RADIOGRAPHS |
MIL-G-82058 Revision D:1984 | GENERATOR SET, DIESEL, 750 KW, 50/60 HERTZ, PRIME, UTILITY |
MIL-STD-633 Revision G:2013 | Standard Family of Mobile Electric Power Generating Sources General Description Information and Characteristic Data |
MIL-S-12511 Revision G:1983 | SPRAYER, INSECTICIDE, FRAME MOUNTED, GASOLINE ENGINE DRIVEN, MIST AND SOLID STREAM, 180 GPH |
MIL-DTL-15303 Revision R:2016 | Audible Signals: Alarms, Bells, Buzzers, Horns, and Sirens, Electronic, Shipboard |
XX-C-2812 Base Document:1993 | COMPRESSOR, AIR, DIESEL-ENGINE-DRIVEN, PORTABLE, WHEEL-MOUNTED |
MIL-STD-2193 Revision C:2012 | Ship Hydraulic System Components |
MIL-PRF-32217 Revision A:2011 | Scale Prevention in Sewage Collection, Holding and Transfer (CHT) and Vacuum CHT (VCHT) Piping Systems for Use on Naval Surface Ships |
MIL-A-52940 Revision C:1987 | AEROSOL GENERATOR, NON-THERMAL, INSECTICIDE, ULTRA LOW VOLUME |
MIL G 38195 : G | GENERATOR SET, GAS TURBINE ENGINE 60 KW 400 HERTZ, GENERAL PURPOSE |
MIL G 53133 : B | GENERATOR SETS, SKID MOUNTED, TACTICAL, QUIET, DIESEL ENGINE DRIVEN, ALTERNATING CURRENT 5 THROUGH 60 KILOWATTS, GENERAL SPECIFICATION FOR |
KKK-E-2808 Base Document:1992 | EXCAVATOR, MULTIPURPOSE, TRUCK MOUNTED, TWO CABS |
MIL-A-53099 Base Document:1990 | ARCTIC FORWARD AREA REFUELLING EQUIPMENT (AFARE) |
MIL-C-62748 Base Document:1994 | CARRIER, 120 MM MORTAR: M1064A3 |
DEFSTAN 00-250(PT1)/1(2008) : 2008 | HUMAN FACTORS FOR DESIGNERS OF SYSTEMS - PART 1: OVERARCHING PEOPLE-RELATED REQUIREMENTS |
MIL-S-52330 Revision E:1993 | SHOP EQUIPMENT, ELECTRICAL REPAIR, SEMITRAILER MOUNTED |
MIL-D-52842 Revision A:1981 | DRIER, X-RAY, FILM FORCED AIR, WALL MOUNTED |
AAS3P-10 : 2011 | SAFETY AND SUITABILITY FOR SERVICE ASSESSMENT TESTING FOR SHOULDER LAUNCHED MUNITIONS |
DI-HFAC-81202 Revision A:2015 | NOISE CONTROL PROGRAM PLAN |
ANSI/ASA S1.1:2013 | ACOUSTICAL TERMINOLOGY |
ANSI S2.20 : 1983 | ESTIMATING AIR BLAST CHARACTERISTICS FOR SINGLE POINT EXPLOSIONS IN AIR, WITH A GUIDE TO EVALUATION OF ATMOSPHERIC PROPAGATION AND EFFECTS |
ANSI S1.4 : 1983 | SPECIFICATION FOR SOUND LEVEL METERS |
ISO 26101:2017 | Acoustics — Test methods for the qualification of free-field environments |
ANSI/ASA S12.42 : 2010 | METHODS FOR THE MEASUREMENT OF INSERTION LOSS OF HEARING PROTECTION DEVICES IN CONTINUOUS OR IMPULSIVE NOISE USING MICROPHONE-IN-REAL-EAR OR ACOUSTIC TEST FIXTURE PROCEDURES |
MIL M 21649 : C | MOUNT, RESILIENT, TYPE 5M1O,OOO-H |
MIL-PRF-32407 Revision A:2016 | MOUNTS, RESILIENT (SURFACE SHIP APPLICATION) |
MIL-HDBK-1473 Revision A:1997 | Color and Marking of Army Materiel |
MIL-HDBK-1908 Revision B:1999 | Definitions of Human Factors Terms |
DI-HFAC-80273 Base Document:1986 | EQUIPMENT STRUCTUREBORNE VIBRATORY ACCELERATION MEASUREMENT |
ANSI/ASA S1.6 : 2016 | PREFERRED FREQUENCIES AND FILTER BAND CENTER FREQUENCIES FOR ACOUSTICAL MEASUREMENTS |
DI-HFAC-80272 Revision A:2015 | MACHINERY AND EQUIPMENT PRE-INSTALLATION AIRBORNE SOUND MEASUREMENTS TEST REPORT |
ANSI/ASA S12.75 : 2012 | METHODS FOR THE MEASUREMENT OF NOISE EMISSIONS FROM HIGH PERFORMANCE MILITARY JET AIRCRAFT |
DI-HFAC-81981 Base Document:2015 | AIR MOVING DEVICE PRE-INSTALLATION AIRBORNE SOUND TESTING AND ACCEPTANCE CRITERIA REPORT |
DI-HFAC-80271 Revision A:2015 | SOUND TEST FAILURE NOTIFICATION AND RECOMMENDATIONS REPORT |
DI-HFAC-80270 Revision A:2015 | MACHINERY AND EQUIPMENT AIRBORNE SOUND MEASUREMENTS TEST PLAN |
DI-HFAC-81278 Revision A:2015 | AIRBORNE NOISE ANALYSIS AND CONTROL DESIGN HISTORY BOOKLET |
MIL-STD-882 Revision E:2012 | System Safety |
ASHRAE 62.1 : 2016 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
ANSI/ASA S1.26 : 2014 | METHOD FOR CALCULATION OF THE ABSORPTION OF SOUND BY THE ATMOSPHERE |
DI-HFAC-80274 Revision A:2015 | MACHINERY AND EQUIPMENT PRE-INSTALLATION STRUCTUREBORNE SOUND MEASUREMENTS TEST REPORT |
MIL-STD-1472 Revision G:2012 | HUMAN ENGINEERING |
SAE J184_201408 | Qualifying A Sound Data Acquisition System |
MIL-DTL-15024 Revision F:1997 | Plates and Tags for Identification of Equipment, General Specification for |
DI-HFAC-81977 Base Document:2015 | SHIP NOISE SURVEYS |
MIL-DTL-19379 Revision C:2013 | Mounts, Resilient, Mare Island Types 11M15, 11M25, and 10M50 |
AMCA 300 : 2014 | REVERBERANT ROOM METHOD FOR SOUND TESTING OF FANS |
MIL M 19863 : D | MOUNT, RESILIENT, TYPE 5B5.000H |
ANSI/ASA S1.11 PART 1 : 2014 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS - PART 1: SPECIFICATIONS |
MIL M 17508 : F | MOUNTS, RESILIENT: TYPES 6E100, 6E150, 7E450, 6E900, 6E2000, 5E3500, 6E100BB, 6E150BB, 7E450BB, AND 6E900BB |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.