ISO/TS 5660-3:2012
Current
The latest, up-to-date edition.
Reaction-to-fire tests — Heat release, smoke production and mass loss rate — Part 3: Guidance on measurement
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
12-06-2012
ISO/TS 5660-3:2012 examines the measurement limitations and applications of the cone calorimeter data as currently used for building products, and recommends ways in which some of these may be overcome for other types of products for other application areas. It compiles information from a large body of experience with regard to the use of the instrument. This information is presented as a set of guidelines, which will help to standardize the use of the cone calorimeter in this wider scope.
Particular guidance is given on aspects of specimen preparation and on the behaviour, such as melting, spalling and intumescing, of specimens exposed to radiant heat. The relevance of specimen thickness and the use of substrate, and methods of fixing to substrate, are also discussed. Advice is given on approaches to testing a variety of "non-standard" products. Recommendations are made on techniques of calibration of the apparatus, selection of appropriate heat flux levels and ignition protocols.
Committee |
ISO/TC 92/SC 1
|
DevelopmentNote |
Supersedes ISO TR 5660-3. (12/2012)
|
DocumentType |
Technical Specification
|
Pages |
44
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PD ISO/TS 5660-3:2012 | Identical |
EN 16755:2017 | Durability of reaction to fire performance - Classes of fire-retardant treated wood products in interior and exterior end use applications |
BS EN ISO 15791-1:2013 | Plastics. Development and use of intermediate-scale fire tests for plastics products General guidance |
I.S. EN ISO 15791-1:2013 | PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE (ISO 15791-1:2014) |
UNE-EN 16755:2018 | Durability of reaction to fire performance - Classes of fire-retardant treated wood products in interior and exterior end use applications |
EN ISO 15791-1:2013 | Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014) |
UNI EN ISO 15791-1 : 2014 | PLASTICS - DEVELOPMENT AND USE OF INTERMEDIATE-SCALE FIRE TESTS FOR PLASTICS PRODUCTS - PART 1: GENERAL GUIDANCE |
IEC 60695-1-12:2015 | Fire hazard testing - Part 1-12: Guidance for assessing the fire hazard of electrotechnical products - Fire safety engineering |
UNE-EN ISO 15791-1:2014 | Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014) |
ISO 15791-1:2014 | Plastics — Development and use of intermediate-scale fire tests for plastics products — Part 1: General guidance |
I.S. EN 16755:2017 | DURABILITY OF REACTION TO FIRE PERFORMANCE - CLASSES OF FIRE-RETARDANT TREATED WOOD PRODUCTS IN INTERIOR AND EXTERIOR END USE APPLICATIONS |
ISO 15928-4:2017 | Houses — Description of performance — Part 4: Fire safety |
DIN EN ISO 15791-1:2014-05 | Plastics - Development and use of intermediate-scale fire tests for plastics products - Part 1: General guidance (ISO 15791-1:2014) |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO/TR 9122-1:1989 | Toxicity testing of fire effluents Part 1: General |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
IEC TS 60695-8-3:2008 | Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products |
ISO 5660-2:2002 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement) |
NFPA 264A : 1994 | STANDARD METHOD OF TEST FOR HEAT RELEASE RATES FOR UPHOLSTERED FURNITURE COMPONENTS OR COMPOSITES AND MATTRESSES USING AN OXYGEN CONSUMPTION CALOMETER |
ISO/TS 14934-1:2002 | Fire tests Calibration and use of radiometers and heat flux meters Part 1: General principles |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO/TR 3814:1989 | Tests for measuring "reaction-to-fire" of building materials — Their development and application |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
ISO 17554:2014 | Reaction to fire tests Mass loss measurement |
ASTM E 1474 : 2014 : REDLINE | Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter |
ISO/TS 14934-4:2007 | Fire tests Calibration of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests |
ISO 554:1976 | Standard atmospheres for conditioning and/or testing — Specifications |
ISO/TR 14697:1997 | Fire tests — Guidance on the choice of substrates for building products |
ISO 13927:2015 | Plastics — Simple heat release test using a conical radiant heater and a thermopile detector |
ISO 14697:2007 | Reaction-to-fire tests — Guidance on the choice of substrates for building and transport products |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
ISO 11907-4:1998 | Plastics — Smoke generation — Determination of the corrosivity of fire effluents — Part 4: Dynamic decomposition method using a conical radiant heater |
ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.