ISO/TR 37137:2014
Current
The latest, up-to-date edition.
Cardiovascular biological evaluation of medical devices — Guidance for absorbable implants
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, French
05-12-2014
The objective of ISO/TR 37137:2014 is to provide interim Part-by-Part guidance on potential adjustments to various test methods within the 10993 series to account for the intentional release of soluble components or degradation products from absorbable medical devices. The content is intended to add clarity and present potentially acceptable approaches for reducing the possibility of erroneous or misleading results due to the nature of the absorbable material. All suggestions should be considered as preliminary and subject to change, with final dispositions implemented through direct modification to the respective parts of ISO 10993. Thus, interim adoption of any of the described adjustments requires an accompanying written justification.
DocumentType |
Technical Report
|
Pages |
17
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
NEN NPR ISO/TR 37137 : 2014 | Identical |
PD ISO/TR 37137:2014 | Identical |
FD ISO/TR 37137 : 2014 FD | Identical |
ANSI/AAMI/ISO 25539-1:2017 | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES |
ISO/TS 17137:2014 | Cardiovascular implants and extracorporeal systems Cardiovascular absorbable implants |
PD ISO/TS 17137:2014 | Cardiovascular implants and extracorporeal systems. Cardiovascular absorbable implants |
AAMI ISO TIR 17137 : 2014 | CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - CARDIOVASCULAR ABSORBABLE IMPLANTS |
I.S. EN ISO 25539-1:2017 | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017) |
ASTM F 3160 : 2016 | Standard Guide for Metallurgical Characterization of Absorbable Metallic Materials for Medical Implants |
BS EN ISO 25539-1:2017 | Cardiovascular implants. Endovascular devices Endovascular prostheses |
DIN EN ISO 25539-1:2015-07 (Draft) | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017) |
ISO 25539-1:2017 | Cardiovascular implants — Endovascular devices — Part 1: Endovascular prostheses |
DIN EN ISO 25539-1:2017-09 | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017) |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 10993-16:2017 | Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables |
ISO/TS 10993-20:2006 | Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
ISO/TR 15499:2016 | Biological evaluation of medical devices Guidance on the conduct of biological evaluation within a risk management process |
ISO 10993-6:2016 | Biological evaluation of medical devices Part 6: Tests for local effects after implantation |