ISO/TR 11583:2012
Current
The latest, up-to-date edition.
Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
03-23-2012
ISO/TR 11583:2012 describes the measurement of wet gas with differential pressure meters. It applies to two-phase flows of gas and liquid in which the flowing fluid mixture consist of gas in the region of 95 % volume fraction or more. ISO/TR 11583:2012 is an extension of ISO 5167. The ranges of gases and liquids from which the equations in ISO/TR 11583:2012 were derived are given. It is possible that the equations do not apply to liquids significantly different from those tested, particularly to highly viscous liquids.
Although the over-reading equations presented in ISO/TR 11583:2012 apply for a wide range of gases and liquids at appropriate gas-liquid density ratios, evaluating gas flow rates depends on information in addition to that required in single-phase flow: a measurement of the pressure loss can be sufficient; measurement of the liquid flow using tracers can be possible; the total mass flow rate may be known (this is more likely in a wet-steam flow than in a natural gas/liquid flow); in a wet-steam flow a throttling calorimeter can be used.
Wet-gas measurement using Venturi tubes or orifice plates is covered in ISO/TR 11583:2012.
DocumentType |
Technical Report
|
Pages |
26
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Standards | Relationship |
PD ISO/TR 11583:2012 | Identical |
API 551 : 2016 | PROCESS MEASUREMENT |
ISO/TR 15377:2007 | Measurement of fluid flow by means of pressure-differential devices Guidelines for the specification of orifice plates, nozzles and Venturi tubes beyond the scope of ISO 5167 |
ISO 3171:1988 | Petroleum liquids — Automatic pipeline sampling |
ISO 10715:1997 | Natural gas — Sampling guidelines |
ISO 3170:2004 | Petroleum liquids — Manual sampling |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
GPA 2165 : 1995 | STANDARD FOR ANALYSIS OF NATURAL GAS LIQUID MIXTURES BY GAS CHROMATOGRAPHY |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ASME MFC 19G : 2008 | WET GAS FLOWMETERING GUIDELINE |
ISO 2186:2007 | Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements |
IP 345 : 80(R1995) | DETERMINATION OF COMPOSITION OF ASSOCIATED NATURAL GAS - GAS CHROMATOGRAPHY METHOD |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |