ISO 18562-4:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 4: Tests for leachables in condensate
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
03-08-2024
English, French
03-13-2017
ISO 18562-4:2017 specifies tests for substances leached by liquid water condensing into gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a patient in all environments. The tests of this document are intended to quantify hazardous water-soluble substances that are leached from the medical device, its parts or accessories by condensate and then conveyed by that liquid to the patient. This document establishes acceptance criteria for these tests.
ISO 18562-4:2017 addresses potential contamination of the gas stream arising from the gas pathways, which is then conducted to the patient.
ISO 18562-4:2017 applies over the expected service life of the medical device in normal use and takes into account the effects of any intended processing or reprocessing
ISO 18562-4:2017 does not address biological evaluation of the surfaces of gas pathways that are in direct contact with the patient. The requirements for direct contact surfaces are found in the ISO 10993 series.
Medical devices, parts or accessories containing gas pathways that are addressed by this document include, but are not limited to, ventilators, anaesthesia workstations (including gas mixers), breathing systems, oxygen conserving devices, oxygen concentrators, nebulizers, low-pressure hose assemblies, humidifiers, heat and moisture exchangers, respiratory gas monitors, respiration monitors, masks, mouth pieces, resuscitators, breathing tubes, breathing systems filters, Y-pieces and any breathing accessories intended to be used with such devices. The enclosed chamber of an incubator, including the mattress, and the inner surface of an oxygen hood are considered to be gas pathways and are also addressed by this document.
ISO 18562-4:2017 does not address contamination already present in the gas supplied from the gas sources while medical devices are in normal use.
EXAMPLE Contamination arriving at the medical device from gas sources such as medical gas pipeline systems (including the non-return valves in the pipeline outlets), outlets of pressure regulators connected or integral to a medical gas cylinder, or room air taken into the medical device is not addressed by ISO 18562 series.
ISO 18562-4:2017 does not address contact with drugs or anaesthetic agents. If a medical device is intended to be used with anaesthetic agents or drugs, then additional testing can be required.
This document is intended to be read in conjunction with ISO 18562‑1.
NOTE This document has been prepared to address the relevant essential principles of safety and performance as indicated in Annex B.
Committee |
ISO/TC 121/SC 3
|
DevelopmentNote |
Supersedes ISO/DIS 18562-4. (03/2017)
|
DocumentType |
Standard
|
Pages |
9
|
PublisherName |
International Organization for Standardization
|
Status |
Superseded
|
SupersededBy | |
UnderRevision |
Standards | Relationship |
NF ISO 18562-4 : 2017 | Identical |
NEN ISO 18562-4 : 2017 | Identical |
BS ISO 18562-4:2017 | Identical |
DIN EN ISO 18562-4:2020-05 | Identical |
ÖNORM EN ISO 18562-4:2020 06 01 | Identical |
NS-EN ISO 18562-4:2020 | Identical |
NEN-EN-ISO 18562-4 : 2020 | Identical |
BS EN ISO 18562-4:2020 | Identical |
I.S. EN ISO 18562-4:2020 | Identical |
UNE-EN ISO 18562-4:2020 | Identical |
PN-EN ISO 18562-4:2020-04 | Identical |
UNI EN ISO 18562-4:2020 | Identical |
NF EN ISO 18562-4:2020 | Identical |
DS/EN ISO 18562-4:2020 | Identical |
DS ISO 18562-4 : 2017 | Identical |
BS ISO 18562-1:2017 | Biocompatibility evaluation of breathing gas pathways in healthcare applications Evaluation and testing within a risk management process |
ISO 18562-1:2017 | Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 1: Evaluation and testing within a risk management process |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 10993-16:2017 | Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables |
ISO/TS 10993-20:2006 | Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices |
ISO 18562-1:2017 | Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 1: Evaluation and testing within a risk management process |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 16142-1:2016 | Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 10993-6:2016 | Biological evaluation of medical devices Part 6: Tests for local effects after implantation |
ISO 7396-1:2016 | Medical gas pipeline systems — Part 1: Pipeline systems for compressed medical gases and vacuum |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.