Hydrometry Selection, establishment and operation of a gauging station

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, French

Published date

12-06-2013

US$111.00
Excluding Tax where applicable

ISO 18365:2013 gives requirements for the establishment and operation of a gauging station for the measurement of stage, or stage and discharge, of a lake, reservoir, river or canal or other artificial open channel. It also describes how a gauging station utilising one of the measurement methods listed should be operated and maintained.

Requirements are provided for stage only measurement stations, stage-discharge stations and direct-discharge measurement stations in natural channels, as well as for stage-discharge stations with artificial structures. Additionally, some requirements are given for measurements under difficult conditions, such as under ice conditions.

DevelopmentNote
Supersedes ISO/DIS 18365, ISO 1100-1 And ISO TR 8363. (12/2013)
DocumentType
Standard
Pages
17
PublisherName
International Organization for Standardization
Status
Current
Supersedes

BS ISO 1438:2017 Hydrometry. Open channel flow measurement using thin-plate weirs
16/30301971 DC : 0 BS ISO 1438 - HYDROMETRY - OPEN CHANNEL FLOW MEASUREMENT USING THIN-PLATE WEIRS
ISO/TR 11651:2015 Estimation of sediment deposition in reservoirs using one dimensional simulation models
ISO 1438:2017 Hydrometry — Open channel flow measurement using thin-plate weirs

ISO 13550:2002 Hydrometric determinations — Flow measurements in open channels using structures — Use of vertical underflow gates
ISO 8368:1999 Hydrometric determinations Flow measurements in open channels using structures Guidelines for selection of structure
ISO 748:2007 Hydrometry Measurement of liquid flow in open channels using current-meters or floats
ISO 6416:2017 Hydrometry — Measurement of discharge by the ultrasonic transit time (time of flight) method
ISO 1100-2:2010 Hydrometry Measurement of liquid flow in open channels Part 2: Determination of the stage-discharge relationship
ISO 4373:2008 Hydrometry Water level measuring devices
ISO 8333:1985 Liquid flow measurement in open channels by weirs and flumes — V-shaped broad-crested weirs
ISO/TS 15768:2000 Measurement of liquid velocity in open channels — Design, selection and use of electromagnetic current meters
ISO 4371:1984 Measurement of liquid flow in open channels by weirs and flumes End depth method for estimation of flow in non-rectangular channels with a free overfall (approximate method)
ISO 9555-1:1994 Measurement of liquid flow in open channels — Tracer dilution methods for the measurement of steady flow — Part 1: General
ISO 9826:1992 Measurement of liquid flow in open channels — Parshall and SANIIRI flumes
ISO/TR 11656:1993 Measurement of liquid flow in open channels Mixing length of a tracer
ISO 9555-3:1992 Measurement of liquid flow in open channels Tracer dilution methods for the measurement of steady flow Part 3: Chemical tracers
ISO 15769:2010 Hydrometry Guidelines for the application of acoustic velocity meters using the Doppler and echo correlation methods
ISO 4359:2013 Flow measurement structures — Rectangular, trapezoidal and U-shaped flumes
ISO 14139:2000 Hydrometric determinations Flow measurements in open channels using structures Compound gauging structures
ISO 9213:2004 Measurement of total discharge in open channels Electromagnetic method using a full-channel-width coil
ISO 3847:1977 Liquid flow measurement in open channels by weirs and flumes — End-depth method for estimation of flow in rectangular channels with a free overfall
ISO 3846:2008 Hydrometry Open channel flow measurement using rectangular broad-crested weirs
ISO 4375:2014 Hydrometry Cableway systems for stream gauging
ISO 4377:2012 Hydrometric determinations — Flow measurement in open channels using structures — Flat-V weirs
ISO/TR 11332:1998 Hydrometric determinations Unstable channels and ephemeral streams
ISO 9555-4:1992 Measurement of liquid flow in open channels Tracer dilution methods for the measurement of steady flow Part 4: Fluorescent tracers
ISO 9827:1994 Measurement of liquid flow in open channels by weirs and flumes — Streamlined triangular profile weirs
ISO 2425:2010 Hydrometry Measurement of liquid flow in open channels under tidal conditions
ISO 4374:1990 Liquid flow measurement in open channels Round-nose horizontal broad-crested weirs
ISO 4362:1999 Hydrometric determinations — Flow measurement in open channels using structures — Trapezoidal broad-crested weirs
ISO 772:1996 Hydrometric determinations — Vocabulary and symbols
ISO/TR 24578:2012 Hydrometry Acoustic Doppler profiler Method and application for measurement of flow in open channels
ISO 4360:2008 Hydrometry Open channel flow measurement using triangular profile weirs
ISO 1438:2017 Hydrometry — Open channel flow measurement using thin-plate weirs