ISO 10993-10:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
11-16-2021
English, French
07-27-2010
ISO 10993-10:2010 describes the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation and skin sensitization.
ISO 10993-10:2010 includes:
- pretest considerations for irritation, including in silico and in vitro methods for dermal exposure;
- details of in vivo (irritation and sensitization) test procedures;
- key factors for the interpretation of the results.
Instructions are given for the preparation of materials specifically in relation to the above tests and several special irritation tests are described for application of medical devices in areas other than skin.
DevelopmentNote |
Supersedes ISO/DIS 10993-10. (07/2010)
|
DocumentType |
Standard
|
Pages |
67
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ONORM EN ISO 10993-10 : 2014 | Identical |
DS EN ISO 10993-10 : 2013 | Identical |
DIN EN ISO 10993-10:2003-02 | Identical |
DIN EN ISO 10993-10:2014-10 | Identical |
GOST ISO 10993-10 : 2011 | Identical |
NBN EN ISO 10993-10 : 2013 | Identical |
NEN EN ISO 10993-10 : 2013 | Identical |
NS EN ISO 10993-10 : 2013 | Identical |
I.S. EN ISO 10993-10:2013 | Identical |
PN EN ISO 10993-10 : 2015 | Identical |
SN EN ISO 10993-10:2013 | Identical |
UNI EN ISO 10993-10 : 2013 | Identical |
SS-EN ISO 10993-10 : 2013 | Identical |
BS EN ISO 10993-10:2013 | Identical |
UNE-EN ISO 10993-10:2013 | Identical |
EN ISO 10993-10:2013 | Identical |
NF EN ISO 10993-10 : 2013 | Identical |
ANSI/AAMI/ISO 10993-10:2010(R2014) | Identical |
BS EN ISO 10993-10:2010 | Identical |
AAMI BE78 : 2002 | Identical |
CSA ISO 10993-10 : 0 | Identical |
GOST R ISO 10993-10 : 2009 | Identical |
AAMI ISO 10993-10 : 2010 | Identical |
UNE-EN ISO 10993-10:2011 | Identical |
ANSI Z80.27 : 2014 | OPHTHALMICS - IMPLANTABLE GLAUCOMA DEVICES |
07/30169357 DC : 0 | BS ISO 25841 - FEMALE CONDOMS - REQUIREMENTS AND TEST METHODS |
DD ISO/TS 10993-20:2006 | Biological evaluation of medical devices Principles and methods for immunotoxicology testing of medical devices |
BS ISO 16840-2:2018 | Wheelchair seating Determination of physical and mechanical characteristics of seat cushions intended to manage tissue integrity |
ASTM F 2407 : 2006 : R2013 : EDT 1 | Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities |
16/30310940 DC : 0 | BS EN ISO 5667-16 - WATER QUALITY - SAMPLING - PART 16: GUIDANCE ON BIOTESTING OF SAMPLES |
04/30103836 DC : DRAFT JUL 2004 | ISO 11979-5 - OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 5: BIOCOMPATIBILITY |
BS ISO 18562-4:2017 | Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for leachables in condensate |
DIN EN ISO 3826-4:2015-12 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 4: APHAERESIS BLOOD BAG SYSTEMS WITH INTEGRATED FEATURES (ISO 3826-4:2015) |
DIN EN 14683:2014-07 | MEDICAL FACE MASKS - REQUIREMENTS AND TEST METHODS |
BS ISO 18666:2015 | Traditional Chinese medicine. General requirements of moxibustion devices |
15/30278540 DC : 0 | BS ISO 18562-4 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 4: TESTS FOR LEACHABLES IN CONDENSATE |
09/30195717 DC : 0 | BS ISO 29942 - PROPHYLACTIC DAMS - REQUIREMENTS AND TEST METHODS |
06/30106186 DC : 0 | ISO 10993-1 - BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT SYSTEM |
08/30133979 DC : DRAFT MAY 2008 | BS ISO 23409 - MALE CONDOMS - REQUIREMENTS AND TEST METHODS FOR CONDOMS MADE FROM SYNTHETIC MATERIALS |
ISO 25841:2017 | Female condoms — Requirements and test methods |
UNE-EN ISO 22442-1:2016 | Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (ISO 22442-1:2015) |
CEN/TR 16953:2017 | Medical gloves for single use - Guidance for selection |
17/30358658 DC : 0 | BS EN 13795-1 - SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS |
17/30358661 DC : 0 | BS EN 13795-2 - SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 2: CLEAN AIR SUITS |
CSA ISO 10993-7 : 1998 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
UNI EN 14683 : 2014 | MEDICAL FACE MASKS - REQUIREMENTS AND TEST METHODS |
ASTM F 3273 : 2017 | Standard Specification for Wrought Molybdenum-47.5 Rhenium Alloy for Surgical Implants (UNS R03700) |
ASTM F 2212 : 2011 : REDLINE | Standard Guide for Characterization of Type I Collagen as Starting Material for Surgical Implants and Substrates for Tissue Engineered Medical Products (TEMPs) |
ASTM F 2147 : 2001 : R2016 | Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens |
ISO 7405:2008 | Dentistry Evaluation of biocompatibility of medical devices used in dentistry |
I.S. EN ISO 3826-1:2013 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 1: CONVENTIONAL CONTAINERS (ISO 3826-1:2013) |
DIN EN ISO 11979-5:2010-11 | Ophthalmic implants - Intraocular lenses - Part 5: Biocompatibility (ISO 11979-5:2006) |
DIN EN ISO 22442-1:2016-05 | Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (ISO 22442-1:2015) |
BS EN ISO 10993-1 : 2009-10 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009) |
BS EN ISO 10993-12:2012 | Biological evaluation of medical devices Sample preparation and reference materials |
BS EN ISO 22803:2005 | Dentistry. Membrane materials for guided tissue regeneration in oral and maxillofacial surgery. Contents of a technical file |
BS EN 455-3:2015 | Medical gloves for single use Requirements and testing for biological evaluation |
BS EN ISO 14534:2015 | Ophthalmic optics. Contact lenses and contact lens care products. Fundamental requirements |
ISO 9394:2012 | Ophthalmic optics — Contact lenses and contact lens care products — Determination of biocompatibility by ocular study with rabbit eyes |
BS EN ISO 9394:2012 | Ophthalmic optics. Contact lenses and contact lens care products. Determination of biocompatibility by ocular study with rabbit eyes |
EN 12011 : 1998 | INSTRUMENTATION TO BE USED IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS |
UNI EN ISO 10993-12 : 2012 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION AND REFERENCE MATERIALS |
VDI 5703:2015-09 | Systematical development for a model-based testing of medical devices |
NBR ISO 8009 : 2009 | MECHANICAL CONTRACEPTIVES - REUSABLE NATURAL AND SILICONE RUBBER CONTRACEPTIVE DIAPHRAGMS - REQUIREMENTS AND TESTS |
NBR ISO 10993-7 : 2005 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
ONORM EN ISO 11979-5 : 2010 | OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 5: BIOCOMPATIBILITY |
ONORM EN ISO 10993-1 : 2011 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS |
08/30181526 DC : DRAFT MAY 2008 | BS EN ISO 15747 - PLASTIC CONTAINERS FOR INTRAVENOUS INJECTIONS |
PREN 14683 : DRAFT 2017 | MEDICAL FACE MASKS - REQUIREMENTS AND TEST METHODS |
PREN 13795-1 : DRAFT 2017 | SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS |
ANSI/AAMI/ISO 15675:2016 | CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - CARDIOPULMONARY BYPASS SYSTEMS - ARTERIAL BLOOD LINE FILTERS |
AAMI ISO 10993-7:2008(R2012) | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
15/30321715 DC : 0 | BS ISO 15675 - CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - CARDIOPULMONARY BYPASS SYSTEMS - ARTERIAL BLOOD LINE FILTERS |
17/30344601 DC : 0 | BS EN ISO 10993-1 - BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS |
ISO 20308:2017 | Traditional Chinese medicine — Gua Sha instruments |
04/19976241 DC : DRAFT AUG 2004 | |
13/30281504 DC : 0 | BS EN 455-3 - MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
06/30097290 DC : DRAFT FEB 2006 | ISO 10993-7 - BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
15/30303073 DC : 0 | BS ISO 25841 - FEMALE CONDOMS - REQUIREMENTS AND TEST METHODS |
08/30179592 DC : DRAFT MAR 2008 | BS ISO 15675 - CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - CARDIOPULMONARY BYPASS SYSTEMS - ARTERIAL BLOOD LINE FILTERS |
ANSI Z80.7 : 2013 | OPHTHALMIC OPTICS - INTRAOCULAR LENSES |
AAMI TIR30 : 2011 | A COMPENDIUM OF PROCESSES, MATERIALS, TEST METHODS, AND ACCEPTANCE CRITERIA FOR CLEANING REUSABLE MEDICAL DEVICES |
ISO 18562-4:2017 | Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 4: Tests for leachables in condensate |
ISO 18763:2016 | Soil quality — Determination of the toxic effects of pollutants on germination and early growth of higher plants |
PD CEN/TR 16953:2017 | Medical gloves for single use. Guidance for selection |
ASTM F 2407 : 2006 | Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities |
ASTM F 3089 : 2014 | Standard Guide for Characterization and Standardization of Polymerizable Collagen-Based Products and Associated Collagen-Cell Interactions |
DIN EN ISO 3826-1:2013-09 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 1: CONVENTIONAL CONTAINERS (ISO 3826-1:2013) |
ISO 16038:2017 | Male condoms — Guidance on the use of ISO 4074 and ISO 23409 in the quality management of condoms |
UNI EN ISO 3826-1 : 2013 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 1: CONVENTIONAL CONTAINERS |
DIN EN ISO 22803:2006-01 | Dentistry - Membrane materials for guided tissue regeneration in oral and maxillofacial surgery - Contents of a technical file (ISO 22803:2004) |
DIN EN ISO 4074:2016-05 | NATURAL RUBBER LATEX MALE CONDOMS - REQUIREMENTS AND TEST METHODS (ISO 4074:2015) |
DIN EN ISO 10993-12:2012-10 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
DIN EN ISO 9394:2013-01 | Ophthalmic optics - Contact lenses and contact lens care products - Determination of biocompatibility by ocular study with rabbit eyes (ISO 9394:2012) |
BS EN ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives Application of risk management |
I.S. EN ISO 14534:2015 | OPHTHALMIC OPTICS - CONTACT LENSES AND CONTACT LENS CARE PRODUCTS - FUNDAMENTAL REQUIREMENTS (ISO 14534:2011) |
I.S. EN ISO 22794:2009 | DENTISTRY - IMPLANTABLE MATERIALS FOR BONE FILLING AND AUGMENTATION IN ORAL AND MAXILLOFACIAL SURGERY - CONTENTS OF A TECHNICAL FILE |
I.S. EN ISO 9394:2012 | OPHTHALMIC OPTICS - CONTACT LENSES AND CONTACT LENS CARE PRODUCTS - DETERMINATION OF BIOCOMPATIBILITY BY OCULAR STUDY WITH RABBIT EYES (ISO 9394:2012) |
I.S. EN ISO 22442-1:2015 | MEDICAL DEVICES UTILIZING ANIMAL TISSUES AND THEIR DERIVATIVES - PART 1: APPLICATION OF RISK MANAGEMENT (ISO 22442-1:2015) |
I.S. EN ISO 10993-8:2000 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 8: SELECTION AND QUALIFICATION OF REFERENCE MATERIALS FOR BIOLOGICAL TESTS |
I.S. EN ISO 4074:2015 | NATURAL RUBBER LATEX MALE CONDOMS - REQUIREMENTS AND TEST METHODS (ISO 4074:2015) |
EN ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (ISO 22442-1:2015) |
I.S. EN ISO 10993-12:2012 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION AND REFERENCE MATERIALS (ISO 10993-12:2012) |
OVE/ONORM EN 60601-1 : 2014 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005 + COR.:2006 + COR.:2007 + A1:2012) |
VDI 3823 Blatt 4:2006-11 | Vacuum coating quality assurance - Testing of vacuum coated plastics |
15/30281262 DC : 0 | BS ISO 18666 - TRADITIONAL CHINESE MEDICINE - GENERAL REQUIREMENTS OF MOXIBUSTION DEVICES |
I.S. EN 12442-1:2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
BS ISO 17218:2014 | Sterile acupuncture needles for single use |
ISO 29942:2011 | Prophylactic dams — Requirements and test methods |
BS ISO 15675:2009 | Cardiovascular implants and artificial organs. Cardiopulmonary bypass systems. Arterial blood line filters |
11/30243462 DC : 0 | BS EN ISO 9394 - OPHTHALMIC OPTICS - CONTACT LENSES AND CONTACT LENS CARE PRODUCTS - DETERMINATION OF BIOCOMPATIBILITY BY OCULAR STUDY WITH RABBIT EYES |
BS ISO 25841:2017 | Female condoms. Requirements and test methods |
17/30343686 DC : 0 | BS EN ISO 7405 - DENTISTRY - EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY |
BS ISO 27427:2013 | Anaesthetic and respiratory equipment. Nebulizing systems and components |
AAMI ISO 10993-1:2009 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS |
12/30251858 DC : 0 | BS ISO 4074 - NATURAL RUBBER LATEX MALE CONDOMS - REQUIREMENTS AND TEST METHODS |
BS ISO 16038:2017 | Male condoms. Guidance on the use of ISO 4074 and ISO 23409 in the quality management of condoms |
BS ISO 23409:2011 | Male condoms. Requirements and test methods for condoms made from synthetic materials |
09/30207531 DC : 0 | BS EN ISO 14534 - OPHTHALMIC OPTICS - CONTACT LENSES AND CONTACT LENS CARE PRODUCTS - FUNDAMENTAL REQUIREMENTS |
03/101659 DC : DRAFT JAN 2003 | ISO 22803 - DENTISTRY - MEMBRANE MATERIALS FOR GUIDED TISSUE REGENERATION IN ORAL AND MAXILLOFACIAL SURGERY - CONTENTS OF A TECHNICAL FILE |
ISO/TS 20993:2006 | Biological evaluation of medical devices Guidance on a risk-management process |
ANSI/AAMI/ISO 22442-1:2016 | MEDICAL DEVICES UTILIZING ANIMAL TISSUES AND THEIR DERIVATIVES - PART 1: APPLICATION OF RISK MANAGEMENT |
AAMI ISO 10993-7 : 2008 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
ANSI/AAMI/ISO TIR10993-20:2006 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 20: PRINCIPLES AND METHODS FOR IMMUNOTOXICOLOGY TESTING OF MEDICAL DEVICES |
AAMI TIR30:2011(R2016) | A COMPENDIUM OF PROCESSES, MATERIALS, TEST METHODS, AND ACCEPTANCE CRITERIA FOR CLEANING REUSABLE MEDICAL DEVICES |
ISO 15675:2016 | Cardiovascular implants and artificial organs — Cardiopulmonary bypass systems — Arterial blood line filters |
ISO 16037:2002 | Rubber condoms for clinical trials Measurement of physical properties |
ASTM F 2808 : 2017 : REDLINE | Standard Test Method for Performing Behind-the-Knee (BTK) Test for Evaluating Skin Irritation Response to Products and Materials That Come Into Repeated or Extended Contact with Skin |
ASTM F 2147 : 2001 | Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens |
ISO/TS 10993-20:2006 | Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices |
ISO 16840-10:2014 | Wheelchairs Resistance to ignition of non-integrated seat and back support cushions Part 10: Requirements and test methods |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
DIN EN ISO 22794:2009-11 | Dentistry - Implantable materials for bone filling and augmentation in oral and maxillofacial surgery - Contents of a technical file (ISO 22794:2007, corrected version 2009-01-15) |
DIN EN ISO 10993-7:2009-02 | Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals (ISO 10993-7:2008) |
DIN EN 455-3:2015-07 | Medical gloves for single use - Part 3: Requirements and testing for biological evaluation |
DIN EN ISO 10993-1:2010-04 | Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management system (ISO 10993-1:2009) |
ISO 22794:2007 | Dentistry Implantable materials for bone filling and augmentation in oral and maxillofacial surgery Contents of a technical file |
I.S. EN ISO 10993-7:2008 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008) |
I.S. EN ISO 11979-5:2006 | OPHTHALMIC IMPLANTS - INTRAOCULAR LENSES - PART 5: BIOCOMPATIBILITY |
EN ISO 11979-5:2006 | Ophthalmic implants - Intraocular lenses - Part 5: Biocompatibility (ISO 11979-5:2006) |
EN ISO 3826-4:2015 | Plastics collapsible containers for human blood and blood components - Part 4: Aphaeresis blood bag systems with integrated features (ISO 3826-4:2015) |
BS EN ISO 7405 : 2008 | DENTISTRY - EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY (ISO 7405:2008) |
ONORM EN ISO 10993-7 : 2010 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
UNI EN ISO 10993-7 : 2009 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
UNI EN ISO 9394 : 2013 | OPHTHALMIC OPTICS - CONTACT LENSES AND CONTACT LENS CARE PRODUCTS - DETERMINATION OF BIOCOMPATIBILITY BY OCULAR STUDY WITH RABBIT EYES |
S.R. CEN/TR 16953:2017 | MEDICAL GLOVES FOR SINGLE USE - GUIDANCE FOR SELECTION |
UNI EN ISO 10993-1 : 2010 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS |
BS ISO 8009:2014 | Mechanical contraceptives. Reusable natural and silicone rubber contraceptive diaphragms. Requirements and tests |
I.S. EN 12011:1998 | INSTRUMENTATION TO BE USED IN ASSOCIATION WITH NON-ACTIVE SURGICAL IMPLANTS - GENERAL REQUIREMENTS |
PREN 455-3 : DRAFT 2013 | MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
13/30259011 DC : 0 | BS ISO 17218 - STERILE ACUPUNCTURE NEEDLES FOR SINGLE USE |
BS ISO 29942:2011 | Prophylactic dams. Requirements and test methods |
01/563307 DC : DRAFT AUG 2001 | BS ISO 15747 - PLASTICS CONTAINERS FOR INTRAVENOUS INJECTION |
BS ISO 20308:2017 | Traditional Chinese medicine. Gua Sha instruments |
16/30319982 DC : 0 | BS ISO 20308 - TRADITIONAL CHINESE MEDICINE - GUA SHA INSTRUMENTS |
CSA ISO 27427 : 2014 | ANAESTHETIC AND RESPIRATORY EQUIPMENT - NEBULIZING SYSTEMS AND COMPONENTS |
BS EN 14683:2014 | Medical face masks. Requirements and test methods |
I.S. EN ISO 25539-1:2017 | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017) |
ISO 23409:2011 | Male condoms Requirements and test methods for condoms made from synthetic materials |
ISO 17218:2014 | Sterile acupuncture needles for single use |
ISO/TR 37137:2014 | Cardiovascular biological evaluation of medical devices — Guidance for absorbable implants |
PREN ISO 3826-1 : DRAFT 2010 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 1: CONVENTIONAL CONTAINERS |
I.S. EN ISO 7405:2009 | DENTISTRY - EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY (ISO 7405:2008) |
17/30359567 DC : 0 | BS EN 14683 - MEDICAL FACE MASKS - REQUIREMENTS AND TEST METHODS |
DIN EN ISO 7405:2013-12 | DENTISTRY - EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY (ISO 7405:2008 + AMD. 1:2013) |
ASTM F 2147 : 2001 : R2010 | Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens |
ASTM F 2695 : 2012 : REDLINE | Standard Specification for Ultra-High Molecular Weight Polyethylene Powder Blended With Alpha-Tocopherol (Vitamin E) and Fabricated Forms for Surgical Implant Applications |
ASTM F 2147 : 2001 : R2006 | Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens |
EN 14683:2014 | Medical face masks - Requirements and test methods |
UNI EN ISO 7405 : 2013 | DENTISTRY - EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY |
ISO 18666:2015 | Traditional Chinese medicine General requirements of moxibustion devices |
ISO 16840-2:2018 | Wheelchair seating — Part 2: Determination of physical and mechanical characteristics of seat cushions intended to manage tissue integrity |
ISO 8009:2014 | Mechanical contraceptives — Reusable natural and silicone rubber contraceptive diaphragms — Requirements and tests |
I.S. EN 14683:2014 | MEDICAL FACE MASKS - REQUIREMENTS AND TEST METHODS |
DIN EN ISO 14534:2015-08 | Ophthalmic optics - Contact lenses and contact lens care products - Fundamental requirements (ISO 14534:2011) |
BS EN ISO 11979-5:2006 | Ophthalmic implants. Intraocular lenses Biocompatibility |
ISO 3826-1:2013 | Plastics collapsible containers for human blood and blood components Part 1: Conventional containers |
BS EN ISO 10993-7:2008 | Biological evaluation of medical devices Ethylene oxide sterilization residuals |
BS EN 12011:1998 | Instrumentation to be used in association with non-active surgical implants. General requirements |
BS EN ISO 3826-1:2013 | Plastics collapsible containers for human blood and blood components Conventional containers |
ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives Part 1: Application of risk management |
UNE-EN ISO 4074:2016 | Natural rubber latex male condoms - Requirements and test methods (ISO 4074:2015) |
UNE-EN 455-3:2015 | Medical gloves for single use - Part 3: Requirements and testing for biological evaluation |
UNE-EN ISO 10993-12:2013 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
UNE-EN ISO 3826-1:2013 | Plastics collapsible containers for human blood and blood components - Part 1: Conventional containers (ISO 3826-1:2013) |
ISO 14534:2011 | Ophthalmic optics Contact lenses and contact lens care products Fundamental requirements |
UNE-EN ISO 9394:2013 | Ophthalmic optics - Contact lenses and contact lens care products - Determination of biocompatibility by ocular study with rabbit eyes (ISO 9394:2012) |
UNE-EN ISO 14534:2015 | Ophthalmic optics - Contact lenses and contact lens care products - Fundamental requirements (ISO 14534:2011) |
ISO 11979-5:2006 | Ophthalmic implants Intraocular lenses Part 5: Biocompatibility |
I.S. EN ISO 10993-1:2009+AC:2010 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009) |
I.S. EN 455-3:2015 | MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
ISO 4074:2015 | Natural rubber latex male condoms Requirements and test methods |
BS EN ISO 22794:2009 | Dentistry. Implantable materials for bone filling and augmentation in oral and maxillofacial surgery. Contents of a technical file |
EN ISO 22803:2005 | Dentistry - Membrane materials for guided tissue regeneration in oral and maxillofacial surgery - Contents of a technical file (ISO 22803:2004) |
EN ISO 10993-8 : 2000 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 8: SELECTION AND QUALIFICATION OF REFERENCE MATERIALS FOR BIOLOGICAL TESTS |
EN 455-3:2015 | Medical gloves for single use - Part 3: Requirements and testing for biological evaluation |
EN ISO 22794:2009 | Dentistry - Implantable materials for bone filling and augmentation in oral and maxillofacial surgery - Contents of a technical file (ISO 22794:2007, corrected version 2009-01-15) |
EN ISO 14534:2015 | Ophthalmic optics - Contact lenses and contact lens care products - Fundamental requirements (ISO 14534:2011) |
EN ISO 9394:2012 | Ophthalmic optics - Contact lenses and contact lens care products - Determination of biocompatibility by ocular study with rabbit eyes (ISO 9394:2012) |
EN ISO 4074:2015 | Natural rubber latex male condoms - Requirements and test methods (ISO 4074:2015) |
EN ISO 3826-1:2013 | Plastics collapsible containers for human blood and blood components - Part 1: Conventional containers (ISO 3826-1:2013) |
15/30316155 DC : 0 | BS ISO 16840-2 - WHEELCHAIR SEATING - PART 2: DETERMINATION OF PHYSICAL AND MECHANICAL CHARACTERISTICS OF DEVICES INTENDED TO MANAGE TISSUE INTEGRITY - SEAT CUSHIONS |
10/30233840 DC : 0 | BS ISO 3826-1 - PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 1: CONVENTIONAL CONTAINERS |
BS ISO 18763:2016 | Soil quality. Determination of the toxic effects of pollutants on germination and early growth of higher plants |
PD ISO/TR 37137:2014 | Cardiovascular biological evaluation of medical devices. Guidance for absorbable implants |
BS EN ISO 3826-4:2015 | Plastics collapsible containers for human blood and blood components Aphaeresis blood bag systems with integrated features |
07/30163763 DC : 0 | BS ISO 7405 - DENTISTRY - PRECLINICAL EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY - TEST METHODS FOR DENTAL MATERIALS |
BS ISO 16840-10:2014 | Wheelchairs. Resistance to ignition of non-integrated seat and back support cushions Requirements and test methods |
AAMI ISO 10993-1 : 2009 : R2013 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS |
CSA ISO 5840 : 0 | CARDIOVASCULAR IMPLANTS - CARIDAC VALVE PROSTHESES |
I.S. EN ISO 3826-4:2015 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 4: APHAERESIS BLOOD BAG SYSTEMS WITH INTEGRATED FEATURES (ISO 3826-4:2015) |
EN ISO 10993-12:2012 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
PREN 13795-2 : DRAFT 2017 | SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 2: CLEAN AIR SUITS |
ANSI/AAMI/ISO 10993-12:2012 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION AND REFERENCE MATERIALS |
ASTM F 2848 : 2017 : REDLINE | Standard Specification for Medical-Grade Ultra-High Molecular Weight Polyethylene Yarns |
UNI EN ISO 22794 : 2009 | DENTISTRY - IMPLANTABLE MATERIALS FOR BONE FILLING AND AUGMENTATION IN ORAL AND MAXILLOFACIAL SURGERY - CONTENTS OF A TECHNICAL FILE |
ASTM F 720 : 2017 : REDLINE | Standard Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test |
ONORM EN ISO 7405 : 2013 | DENTISTRY - EVALUATION OF BIOCOMPATIBILITY OF MEDICAL DEVICES USED IN DENTISTRY (ISO 7405:2008 + AMD 1:2013) |
NF EN ISO 10993-1 : 2010 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT SYSTEM PROCESS |
ISO 27427:2013 | Anaesthetic and respiratory equipment — Nebulizing systems and components |
ONORM EN ISO 3826-1 : 2013 | PLASTICS COLLAPSIBLE CONTAINERS FOR HUMAN BLOOD AND BLOOD COMPONENTS - PART 1: CONVENTIONAL CONTAINERS (ISO 3826-1:2013) |
ISO 22803:2004 | Dentistry — Membrane materials for guided tissue regeneration in oral and maxillofacial surgery — Contents of a technical file |
ISO 3826-4:2015 | Plastics collapsible containers for human blood and blood components — Part 4: Aphaeresis blood bag systems with integrated features |
BS EN ISO 4074:2015 | Natural rubber latex male condoms. Requirements and test methods |
EN 12442-1 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
EN ISO 10993-7 : 2008 COR 2009 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009) |
ONORM EN 455-3 : 2015 | MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
ISO 9394:2012 | Ophthalmic optics — Contact lenses and contact lens care products — Determination of biocompatibility by ocular study with rabbit eyes |
ISO 14155-2:2003 | Clinical investigation of medical devices for human subjects Part 2: Clinical investigation plans |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 14155-1:2003 | Clinical investigation of medical devices for human subjects Part 1: General requirements |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.