IEEE C62.62-2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Standard Test Specifications for Surge-Protective Devices (SPDs) for Use on the Load Side of the Service Equipment in Low Voltage (1000 V and less) AC Power Circuits
10-18-2021
English
03-11-2011
1. Overview
2. Normative references
3. Definitions, acronyms, and abbreviations
4. Service conditions
5. General test considerations
6. Performance characteristics and test descriptions
7. SPD Documentation
Annex A (informative) - Additional test and consideration
information
Annex B (informative) - Bibliography
Pertains to surge-protective devices (SPDs) intended to be installed on the load side of the service equipment connected to 50 Hz or 60 Hz alternating current (ac) power circuits rated at 1000 V (root mean squared [rms]) or less.
Committee |
Surge Protective Devices/Low Voltage
|
DevelopmentNote |
Supersedes IEEE DRAFT C62.62. (07/2000)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
C22.2 NO. 269.3-17 | Surge protective devices - Type 3 - Cord connected, direct plug-in and receptacle type |
C22.2 NO. 269.4-17 | Surge protective devices - Type 4 - Component assemblies |
IEEE C62.50-2012 | IEEE Standard for Performance Criteria and Test Methods for Plug-in (Portable) Multiservice (Multiport) Surge-Protective Devices for Equipment Connected to a 120 V/240 V Single Phase Power Service and Metallic Conductive Communication Line(s) |
IEEE C62.44-2016 | IEEE Guide for the Application of Low-Voltage (1000 V rms or Less) Surge Protective Devices Used on Secondary Distribution Systems (Between the Transformer Low-Voltage Terminals and the Line Side of the Service Equipment) |
C22.2 NO. 269.1-17 | Surge protective devices - Type 1 - Permanently connected |
IEEE C62.42-2005 | IEEE Guide for the Application of Component Surge-Protective Devices for Use in Low-Voltage [Equal to or Less than 1000 V (ac) Or 1200 V (dc)] Circuits |
FM 3985 : 2009 | TRANSIENT VOLTAGE SURGE SUPPRESSION DEVICES |
IEEE C62.72-2007 | IEEE Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power Circuits |
CSA C22.2 No. 269 PACKAGE : 2017 | CONSISTS OF C22.2 NO. 269.1-17 - SURGE PROTECTIVE DEVICES - TYPE 1 - PERMANENTLY CONNECTED; C22.2 NO. 269.2-17 - SURGE PROTECTIVE DEVICES - TYPE 2 - PERMANENTLY CONNECTED; C22.2 NO. 269.3-17 - SURGE PROTECTIVE DEVICES - TYPE 3 - CORD CONNECTED, DIRECT PLUG-IN AND RECEPTACLE TYPE; C22.2 NO. 269.4-17 - SURGE PROTECTIVE DEVICES - TYPE 4 - COMPONENT ASSEMBLIES AND C22.2 NO. 269.5-17 - SURGE |
C22.2 NO. 269.2-17 | Surge protective devices - Type 2 - Permanently connected |
C22.2 NO. 269.5-17 | Surge protective devices - Type 5 - Components |
IEEE C62.34 : 1996 | TEST METHODS AND PERFORMANCE OF LOW-VOLTAGE (1000 V RMS OR LESS) SURGE PROTECTIVE DEVICES USED ON SECONDARY DISTRIBUTION SYSTEMS (BETWEEN THE TRANSFORMER LOW-VOLTAGE TERMINALS AND THE LINE SIDE OF THE SERVICE EQUIPMENT) |
IEEE 1143-2012 | IEEE Guide on Shielding Practice for Low Voltage Cables |
IEEE C62.72-2016 | IEEE Guide for the Application of Surge-Protective Devices for Use on the Load Side of Service Equipment in Low-Voltage (1000 V or Less, 50 Hz or 60 Hz) AC Power Circuits |
IEEE C62.72-2007 | IEEE Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power Circuits |
IEEE C62.31-2006 | IEEE Standard Test Methods for Low-Voltage Gas-Tube Surge-Protective Device Components |
IEEE C62.41.2-2002 | IEEE Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and less) AC Power Circuits |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
ANSI C84.1 : 2016 | ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ) |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEEE C62.34 : 1996 | TEST METHODS AND PERFORMANCE OF LOW-VOLTAGE (1000 V RMS OR LESS) SURGE PROTECTIVE DEVICES USED ON SECONDARY DISTRIBUTION SYSTEMS (BETWEEN THE TRANSFORMER LOW-VOLTAGE TERMINALS AND THE LINE SIDE OF THE SERVICE EQUIPMENT) |
IEEE C62.45-2002 | IEEE Recommended Practice on Surge Testing for Equipment Connected to Low-Voltage (1000 V and less) AC Power Circuits |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.