1 Overview
1.1 Scope
1.2 Purpose
2 Normative references
3 Definitions
3.1 Shunt reactor
3.2 Rating of a shunt reactor
3.3 Insulation
3.4 Losses and impedance
3.5 Construction
3.6 Methods of cooling
4 General requirements
4.1 Service conditions
4.2 Effect of air density on flashover voltage
4.3 Frequency
4.4 Effect of altitude on temperature rise
4.5 Electrical properties of insulating oil
4.6 Magnetic characteristics
5 Basis for rating shunt reactors
5.1 kVA ratings
5.2 Terms in which rating is expressed
6 Tests
6.1 General
6.2 Types of tests
7 Losses and impedance
7.1 Total losses
7.2 Impedance
8 Temperature rise
8.1 Life of insulating materials
8.2 Conditions under which temperature limits apply
8.3 Limits of temperature rise for continuous ratings
9 Dielectric tests and insulation levels
9.1 Dielectric tests
9.2 Dielectric tests for line terminals
9.3 Basic lightning-impulse insulation levels and insulation
test levels for neutral terminals
10 Test code
10.1 General
10.2 Resistance measurements
10.3 General dielectric tests
10.4 Losses and impedance
10.5 Temperature-rise tests
10.6 Audible-sound-level test
10.7 Vibration tests on oil-immersed shunt reactors
10.8 Vibration tests on dry-type shunt reactors
10.9 Magnetic characteristic measurements
10.10 Seismic performance verification on oil-immersed and
dry-type shunt reactors
11 Construction for oil-immersed shunt reactors
11.1 Bushings
11.2 Bushing-type current transformers
11.3 Accessories
11.4 Terminal markings
11.5 Oil preservation
11.6 Oil-preservation systems
11.7 Tanks
11.8 Shunt reactor finish
11.9 Other equipment accessories
12 Construction and installation of dry-type shunt reactors
12.1 General description
12.2 Safety
12.3 Magnetic clearances
12.4 Connections
12.5 Installed sound level
12.6 Concrete foundations
12.7 Switching - Circuit breakers
12.8 Protection practices for air-core shunt reactors
Annex A (normative) Specific requirements for dry-type
air-core thyristor-controlled reactors
Annex B (informative) Dielectric stresses imposed on shunt
reactors during switching
Annex C (informative) Dielectric tests including information
on wave shape control
Annex D (informative) Bibliography
This standard Applies to all oil-immersed or dry-type, single-phase or three-phase, outdoor or indoor shunt reactors rated over 500 kVA.
DocumentType |
Standard
|
ISBN |
978-0-7381-5412-1
|
Pages |
106
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
IEEE DRAFT C62.22 : D8 2005 | GUIDE FOR THE APPLICATION OF METAL-OXIDE SURGE ARRESTERS FOR ALTERNATING-CURRENT SYSTEMS |
BS EN 60076-6:2008 | Power transformers Reactors |
IEEE DRAFT C57.16 : D10 AUG 95 | TERMINOLOGY AND TEST CODE FOR DRY-TYPE AIR-CORE SERIES CONNECTED REACTORS |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEC TR 62271-306:2012 | High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers |
IEEE C37.109-2006 REDLINE | IEEE Guide for the Protection of Shunt Reactors |
IEEE C57.117-1986 | IEEE Guide for Reporting Failure Data for Power Transformers and Shunt Reactors on Electric Utility Power Systems |
IEEE DRAFT 1313.2 : D6 DEC 98 | DRAFT GUIDE FOR THE APPLICATION OF INSULATED COORDINATION |
IEEE C57.125-2015 | IEEE Guide for Failure Investigation, Documentation, Analysis, and Reporting for Power Transformers and Shunt Reactors |
IEEE C57.136 : 2000 | IEEE GUIDE FOR SOUND LEVEL ABATEMENT AND DETERMINATION FOR LIQUID-IMMERSED POWER TRANSFORMERS AND SHUNT REACTORS RATED OVER 500 KVA |
CEI EN 60076-6 : 2015 | POWER TRANSFORMERS - PART 6: REACTORS |
IEEE DRAFT 693 : D9 2004 | SEISMIC DESIGN OF SUBSTATIONS |
I.S. EN 60076-6:2008 | POWER TRANSFORMERS - PART 6: REACTORS |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE DRAFT 1313.1 : D11 MAY 95 | INSULATION COORDINATION - DEFINITIONS, PRINCIPLES AND RULES |
IEEE C57.16-2011 | IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors |
IEEE 1303-2011 | IEEE Guide for Static Var Compensator Field Tests |
C88-16 | Power transformers and reactors |
IEEE 1277-2010 | IEEE Standard General Requirements and Test Code for Dry-Type and Oil-Immersed Smoothing Reactors for DC Power Transmission |
IEEE 1313.1-1996 | IEEE Standard for Insulation Coordination - Definitions, Principles and Rules |
IEEE 1623-2004 | IEEE Guide for the Functional Specification of Medium Voltage (1 kV - 35 kV) Electronic Shunt Devices for Dynamic Voltage Compensation |
IEEE C93.3-2017 | IEEE Standard Requirements for Power-Line Carrier Line Traps (30 kHz to 500 kHz) |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
CGA V 1 : 2013 | STANDARD FOR COMPRESSED GAS CYLINDER VALVE OUTLET AND INLET CONNECTIONS |
IEEE 32-1972 | IEEE Standard Requirements, Terminology, and Test Procedures for Neutral Grounding Devices |
ANSI S1.4 : 1983 | SPECIFICATION FOR SOUND LEVEL METERS |
ANSI S1.11 : 2014 | SPECIFICATION FOR OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND ANALOG AND DIGITAL FILTERS |
IEEE C57.16-2011 | IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors |
IEEE C57.19.01-2000 | IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE C57.19.00 : 2004 | GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
ASME B1.20.1 : 2013(R2018) | PIPE THREADS, GENERAL PURPOSE (INCH) |
IEEE C57.98-2011 | IEEE Guide for Transformer Impulse Tests |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
ANSI C84.1 : 2016 | ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ) |
IEEE 1277-2010 | IEEE Standard General Requirements and Test Code for Dry-Type and Oil-Immersed Smoothing Reactors for DC Power Transmission |
IEEE C63.2-2009 | American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
IEEE C37.015-2009 | IEEE Guide for the Application of Shunt Reactor Switching |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEEE C37.109-2006 REDLINE | IEEE Guide for the Protection of Shunt Reactors |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEEE C57.106-2006 | IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.