IEEE C57.143-2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
IEEE Guide for Application for Monitoring Equipment to Liquid-Immersed Transformers and Components
03-30-2023
English
12-19-2012
1. Overview
2. Normative references
3. Definitions
4. Surveillance needs of high-voltage
transformers and accessories
5. Monitored parameters
6. Monitoring systems and equipment
7. Cost benefits
Annex A (informative) - Bibliography
Annex B (informative) - Bushing power factor
and capacitance
Annex C (informative) - Partial discharge: electrical
and acoustic methods
Annex D (informative) - Direct winding temperature
Annex E (informative) - Communications protocols
for on-line monitoring equipment
Aims to provide guidance to those who specify, apply, install and use on-line monitoring equipment on liquid-immersed power transformers and their components.
Committee |
Transformers
|
DocumentType |
Standard
|
ISBN |
978-0-7381-8027-4
|
Pages |
83
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Withdrawn
|
IEEE C57.12.10-2010 REDLINE | IEEE Standard Requirements for Liquid-Immersed Power Transformers |
17/30331680 DC : 0 | BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS |
IEEE C57.140-2006 | IEEE Guide for Evaluation and reconditioning of Liquid Immersed Power Transformers |
IEEE C57.152-2013 | IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors |
IEEE C57.104-2019 | IEEE Guide for the Interpretation of Gases Generated in Mineral Oil-Immersed Transformers |
IEEE C57.140-2017 | IEEE Guide for Evaluation and Reconditioning of Liquid Immersed Power Transformers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
IEEE C57.127-2007 | IEEE Guide for the Detection and Location of Acoustic Emissions from Partial Discharges in Oil-Immersed Power Transformers and Reactors |
IEC 60870-5-4:1993 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 4: Definition and coding of application information elements |
IEEE 1379-1997 | IEEE Recommended Practice for Data Communications Between Intelligent Electronic Devices and Remote Terminal Units in a Substation |
IEEE C57.13.3-2005 | IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases |
IEEE C57.13.3-2014 | IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases |
IEC 60599:2015 | Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis |
IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
IEC 60870-5-101:2003+AMD1:2015 CSV | Telecontrol equipment and systems - Part 5-101: Transmissionprotocols - Companion standard for basic telecontrol tasks |
IEC 60870-5-5:1995 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 5: Basic application functions |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE C57.139-2010 | IEEE Guide for Dissolved Gas Analysis in Transformer Load Tap Changers |
IEEE C57.104-2008 | IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers |
IEEE 80-2013 REDLINE | IEEE Guide for Safety in AC Substation Grounding |
IEEE C57.148-2011 | IEEE Standard for Control Cabinets for Power Transformers |
IEEE C37.90.2:2004 | WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS |
IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
IEC 60870-5-2:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 2: Link transmission procedures |
IEEE C57.125-2015 | IEEE Guide for Failure Investigation, Documentation, Analysis, and Reporting for Power Transformers and Shunt Reactors |
IEC 60870-5-1:1990 | Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats |
IEC 60870-5-3:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 3: General structure of application data |
IEEE C37.101-2006 REDLINE | IEEE Guide for Generator Ground Protection |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.