IEEE C37.12-2008 REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Guide for Specifications of High-Voltage Circuit Breakers (over 1000 Volts)
04-16-2019
English
04-03-2009
1 Overview
1.1 Scope
1.2 Purpose
2 Normative references
3 Definitions
4 Specification format
5 General specification
5.1 General scope
5.2 General references
5.3 General definitions
5.4 Service conditions
5.5 Electrical characteristics
5.6 Construction
5.7 Vacuum circuit breakers
5.8 Gas circuit breakers
5.9 Operating mechanism
5.10 Controls
5.11 Accessories and appurtenances
5.12 Tests
5.13 Drawings and instruction manuals
5.14 Shipping
5.15 Spare parts
5.16 Circuit breaker information to be furnished by
manufacturer or supplier with bid/tender to
facilitate bid evaluation
6 Supplementary specification
6.1 Purchaser's specification number and date
6.2 Number of circuit breakers required and delivery requirements
6.3 System characteristics
6.4 Application
6.5 Circuit breaker electrical characteristics
6.6 Circuit breaker physical characteristics
6.7 Bushing characteristics
6.8 Operating mechanism and auxiliaries
6.9 Current and potential devices
6.10 Miscellaneous
6.11 Non-standard Tests required by user
6.12 Shipping instructions
Annex A (informative) Bibliography
Gives assistance for development of specifications that apply to all indoor and outdoor types of ac high-voltage circuit breakers rated above 1000 volts.
Committee |
Switchgear
|
DevelopmentNote |
Supersedes IEEE DRAFT C37.12. (04/2009) Supersedes ANSI C37.12. (10/2010)
|
DocumentType |
Standard
|
Pages |
103
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
C22.2 NO. 31-18 | Switchgear assemblies |
IEEE C37.10-2011 REDLINE | IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker Failures |
IEEE DRAFT C37.013A : D6 2006 | AC HIGH VOLTAGE GENERATOR CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 1: SUPPLEMENT FOR USE WITH GENERATORS RATED 10-100 MVA |
IEEE C37.011-2005 | IEEE Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers |
IEEE C37.013-1997 | IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
IEEE 1291-1993 | IEEE Guide for Partial Discharge Measurement in Power Switchgear |
NEMA 107:2016 | Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus |
IEEE C37.012-2005 | IEEE Application Guide for Capacitance Current Switching for AC High-Voltage Circuit Breakers |
IEEE C37.10.1-2000 | IEEE Guide for the Selection of Monitoring for Circuit Breakers |
IEEE C37.09a-2005 | TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 1: CAPACITANCE CURRENT SWITCHING |
IEEE C37.81-1989 | IEEE Guide for Seismic Qualification of Class 1E Metal-Enclosed Power Switchgear Assemblies |
IEEE C37.04B : 2008 | RATING STRUCTURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 2: TO CHANGE THE DESCRIPTION OF TRANSIENT RECOVERY VOLTAGE FOR HARMONIZATION WITH IEC 62271-100 |
NEMA SG 4:2009(R2013) | ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS |
IEEE C37.010-1999 | IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.11-2014 | IEEE Standard Requirements for Electrical Control for AC High-Voltage (>1000 V) Circuit Breakers |
IEEE C37.011-2011 REDLINE | IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers |
IEEE C37.015-1993 | IEEE Application Guide for Shunt Reactor Switching |
IEEE C37.06-2009 | AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.012-2014 | IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 V |
IEEE C37.04a-2003 | RATING STRUCTURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 1: CAPACITANCE CURRENT SWITCHING |
IEEE C37.015-2009 | IEEE Guide for the Application of Shunt Reactor Switching |
IEEE DRAFT C37.06 : D6 2004 | AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
IEEE C37.12.1-2007 | IEEE Guide for High-Voltage (>1000 V)Circuit Breaker Instruction Manual Content |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEEE C37.101-2006 REDLINE | IEEE Guide for Generator Ground Protection |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.