IEEE 82 : 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS
Hardcopy , PDF
05-20-2019
English
03-03-2003
1 Overview
1.1 Scope
1.2 Purpose
2 References
3 Testing equipment
3.1 Impulse generator
3.2 Wave shape
4 Specimen
4.1 Length
4.2 Electrode arrangement
4.3 Sample terminations
5 Test procedures
5.1 Test temperature
5.2 Sample conditioning
5.3 Basic Impulse Insulation Level (BIL) qualification
tests
5.4 Impulse design test
5.5 Switching impulse test
5.6 Test reports
Annex A (informative) - Bibliography
Applies to both switching impulse and lightning impulse tests on cables or cable systems incorporating laminated or extruded insulations. Includes high-pressure pipe cable, low-pressure gas-filled cable, self-contained liquid-filled cable, solid-paper cable, and other taped cable designs.
DocumentType |
Standard
|
ISBN |
978-0-7381-3490-1
|
Pages |
16
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
CSA C68.5 : 2013 | SHIELDED AND CONCENTRIC NEUTRAL POWER CABLE FOR DISTRIBUTION UTILITIES |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
CSA C22.2 No. 241 : 0 | IEEE STANDARD FOR CABLE JOINTS FOR USE WITH EXTRUDED DIELECTRIC CABLE RATED 5000-138000 V AND CABLE JOINTS FOR USE WITH LAMINATED DIELECTRIC CABLE RATED 2500-500000 V |
IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
ICEA S 94 649 : 2013 | CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV |
ICEA S 97 682 : 2013 | UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV |
IEEE DRAFT 525 : D15 2006 | DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS |
IEEE DRAFT 404 : D13 2006 | EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V |
IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
IEEE 404-2012 | IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV |
IEEE 789-2013 | IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments |
IEEE 386-2016 | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEEE 404-2012 | IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.