IEEE 789-2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments
Hardcopy , PDF
03-21-2024
English
08-13-2013
1. Overview
2. Normative references
3. Definitions
4. General information
5. Basic requirements
6. Environmental considerations
7. Electrical requirements
8. Installation practices
9. Cable design requirements
10. Testing and test methods
Annex A (informative) - Bibliography
Annex B (informative) - Insulation and jacketing PE compounds
for conductors
Annex C (informative) - Attenuation information
Annex D (informative) - Capacitance unbalance and characteristic
impedance information
This standard applies to wires and cables, used principally for power system communications and control purposes, which are located within electric supply locations or are installed within the zone of influence (ZOI) of the power station ground potential rise (GPR), or which may be buried adjacent to electric power transmission and distribution lines.
Committee |
Power System Communications and Cybersecurity
|
DocumentType |
Standard
|
ISBN |
978-0-7381-8486-9
|
Pages |
48
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Withdrawn
|
Supersedes |
IEEE 487.3-2014 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of Hybrid Facilities |
IEEE 1590-2009 | IEEE Recommended Practice for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Using Optical Fiber Systems |
IEEE 487.1-2014 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of On-Grid Isolation Equipment |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
IEEE 487.2-2013 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations through the Use of Optical Fiber Systems |
IEEE 487.4-2013 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of Neutralizing Transformers |
IEEE 487.5-2013 | IEEE Standard for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Through the Use of Isolation Transformers |
IEEE 776-1992 | IEEE Recommended Practice for Inductive Coordination of Electric Supply and Communication Lines |
IEEE 487-2015 | IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations |
IEEE 1143-2012 | IEEE Guide on Shielding Practice for Low Voltage Cables |
IEEE 628-2011 | IEEE Standard Criteria for the Design, Installation, and Qualification of Raceway Systems for Class 1E Circuits for Nuclear Power Generating Stations |
IEEE 1202-2006 | IEEE Standard for Flame-Propagation Testing of Wire & Cable |
IEEE 525-2007 | IEEE Guide for the Design and Installation of Cable Systems in Substations |
IEEE 80-2000 | IEEE Guide for Safety in AC Substation Grounding |
IEEE 1615-2007 | IEEE Recommended Practice for Network Communication in Electric Power Substations |
IEEE 487-2015 | IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations |
ASTM D 1248 : 2016 : REDLINE | Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable |
TIA 568-0 : D2015 AMD 1 2017 | GENERIC TELECOMMUNICATIONS CABLING FOR CUSTOMER PREMISES |
ASTM G 21 : 2015 : REDLINE | Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi |
ICEA S 73 532 : 2014 | STANDARD FOR CONTROL, THERMOCOUPLE, EXTENSION AND INSTRUMENTATION CABLE |
ICEA S 90 661 : 2012 | CATEGORY 3, 5, & 5E INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WIRING SYSTEMS TECHNICAL REQUIREMENTS |
IEEE 487-2007 | IEEE Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply Locations |
IEEE 532-2007 REDLINE | IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables |
ICEA S 85 625 : 2016 | TELECOMMUNICATIONS CABLE AIRCORE, POLYOLEFLN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS |
UL 444:5ED 2017-01-20 | Communications Cables |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
TIA/EIA 568-2 : C2009 AMD 1 2016 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 2: BALANCED TWISTED-PAIR TELECOMMUNICATIONS CABLING AND COMPONENTS STANDARDS |
IEEE 1222-2011 | IEEE Standard for Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power Lines |
IEEE 82 : 2002 | TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS |
ICEA S 104 696 : 2013 | INDOOR-OUTDOOR OPTICAL FIBER CABLE |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEEE 80-2013 REDLINE | IEEE Guide for Safety in AC Substation Grounding |
TIA/EIA 568-3 : D2016 | OPTICAL FIBER CABLING AND COMPONENTS STANDARD |
IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |
IEEE/ANSI 455-1985 | IEEE Standard Test Procedure for Measuring Longitudinal Balance of Telephone Equipment Operating in the Voice Band |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEEE C37.90.2:2004 | WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS |
IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
IEEE 690-2004 | IEEE Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear Power Generating Stations |
ATIS 0600316 : 2013 | ELECTRICAL PROTECTION OF TELECOMMUNICATIONS OUTSIDE PLANT |
ASTM D 257 : 2014 : REDLINE | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
IEEE 422-2012 | IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities |
TIA 568-4 : D2017 | BROADBAND COAXIAL CABLING AND COMPONENTS STANDARD |
ICEA S 83 596 : 2016 | INDOOR OPTICAL FIBER CABLE |
ICEA S 102 700 : 2004 | CATEGORY 6 INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN COMMUNICATIONS WIRING SYSTEMS TECHNICAL REQUIREMENTS |
IEEE 1143-2012 | IEEE Guide on Shielding Practice for Low Voltage Cables |
ASTM D 746 : 2014 : REDLINE | Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact |
IEEE 1185-2010 | IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities |
IEEE 367-2012 | IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.