• There are no items in your cart

IEEE 1560-2005

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

IEEE Standard for Methods of Measurement of Radio Frequency Power Line Interference Filter in the Range of 100 Hz to 10 GHz

Available format(s)

PDF

Withdrawn date

03-30-2023

Language(s)

English

Published date

02-24-2006

US$130.68
Excluding Tax where applicable

1 Overview
   1.1 Scope
   1.2 Purpose
   1.3 Application of test methods and use of this document
2 Normative references
3 Definitions
4 Safety
   4.1 Stored capacitor energy
   4.2 RF hazards
   4.3 Voltages and currents
5 Measurement instrumentation
   5.1 General
   5.2 Calibration of measuring equipment
   5.3 Measurement tolerances
6 Measurement uncertainty
   6.1 General
   6.2 Calculation of measurement uncertainty
7 Test equipment and minimum specifications
   7.1 AC power source
   7.2 Alternating current source
   7.3 DC power source
   7.4 Direct current source
   7.5 Ammeter
   7.6 Buffer networks
   7.7 Differential voltage probes
   7.8 Dynamic range
   7.9 Ground plane
   7.10 Impedance-transforming networks
   7.11 Line-impedance stabilization network
   7.12 Linear load
   7.13 Nonlinear load
   7.14 Oscilloscope
   7.15 Power amplifier
   7.16 Power analyzer
   7.17 Attenuators, 100 dB
   7.18 RF matching network
   7.19 RF bulk current injection probe
   7.20 RF current transformers
   7.21 RF injector
   7.22 Shielded enclosure
   7.23 Spectrum analyzer or network analyzer
   7.24 S-parameter test set
   7.25 Tracking generator
8 Test facilities
   8.1 Standard testing conditions
   8.2 General operating conditions
   8.3 Grounding
   8.4 Regulatory agency restrictions
   8.5 Screened equipment and shielding requirements
   8.6 RF test fixture and mounting requirements
   8.7 Source impedance
   8.8 Test equipment noise floor level
   8.9 Attenuators, phase splitters, power splitters, and
        network matching pads
   8.10 Lead dress
9 Divisions of frequency ranges and recommended sensitivity
10 Required measurement methods
   10.1 Quality assurance testing - No load (10 kHz to 1 GHz)
   10.2 Quality assurance test - Loaded (10 kHz to 20 MHz)
   10.3 RF characteristic test, mismatched impedance - No load
        (100 kHz to 30 MHz)
   10.4 Variable source impedance attenuation measurement (100 Hz
        to 100 kHz)
   10.5 Attenuation measurement (100 kHz to 30 MHz)
   10.6 Aperture leak testing by electric fields (1 GHz to 10 GHz)
   10.7 Voltage drop and waveform quality test (linear/nonlinear
        loading)
   10.8 S-parameter measurement (100 Hz to 30 MHz)
11 Record keeping and data handling
Annex A (informative) Bibliography
Annex B (normative) Filter labeling
Annex C (informative) Waveform quality and harmonic
        loading-related performance of power-line filters
Annex D (informative) S-Parameters
Annex E (informative) Line-impedance stabilization networks
Annex F (informative) Frequency response curves
Annex G (informative) Designing RFI filters for their worst-case
        behavior
Annex H (informative) Estimating measurement uncertainty
Annex I (informative) Glossary

Presents a standard method of measurement for evaluating the electromagnetic and radio frequency suppression capability of power-line filters in the frequency range of 100 Hz to 10 GHz.

Committee
Standards Development Committee
DevelopmentNote
Supersedes IEEE DRAFT 1560. (02/2006)
DocumentType
Standard
ISBN
978-0-7381-4809-0
Pages
92
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn

IEEE/ANSI C63.26-2015 IEEE/ANSI Standard for Compliance Testing of Transmitters Used in Licensed Radio Services

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEEE 1528-2003 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
MIL-STD-220 Revision C:2009 Method of Insertion Loss Measurement
IEEE 299-2006 IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures
MIL-PRF-15733 Revision J:2010 FILTERS AND CAPACITORS, RADIO FREQUENCY INTERFERENCE, GENERAL SPECIFICATION FOR
IEEE/ASTM SI_10-2010 American National Standard for Metric Practice
CISPR 16-2:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity
MIL-STD-461 Revision G:2015 REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
IEEE C63.2-2009 American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEEE C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz
IEEE/ANSI C63.2-1996 American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz - Specifications
IEEE 1250-2011 REDLINE IEEE Guide for Identifying and Improving Voltage Quality in Power Systems
CISPR 17:2011 Methods of measurement of the suppression characteristics of passive EMC filtering devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.