Fire hazard testing - Part 7-51: Toxicity of fire effluent - Estimation of toxic potency: Calculation and interpretation of test results
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-28-2016
English - French
03-26-2002
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Principle of the method
5 Method
5.1 General
5.2 Calculation of predicted toxic potency of
effluent using FED principles
Annex A (informative) Illustrative example
Annex B (informative) Illustrative example: Calculation
of FLD in a hypothetical fire, based on data from
a tube furnace interlaboratory round-robin test
B.1 Assumptions
B.2 Known reference data: toxic potency of component
toxic gases
B.3 Calculations
B.3.1 Mass loss integral, D[m]
B.3.2 Volume yields calculated from tube furnace
test data
B.3.3 Calculation of FLD
Annex C (informative) Nomenclature
Describes the calculation procedure for converting the data generated by chemical analysis in IEC 60695-7-50 into predicted toxic potency data for material tested under defined conditions. This is in order to estimate the contribution of the fire effluent of an end-product or material to the toxic threat to life of the total fire effluent resulting from a fire scenario in which the end-product or material is involved.This method may also be suitable for converting data from other relevant test methods into predicted toxic potency, provided that the form and format of the data is compatible with that of IEC 60695-7-50.This method is intended to be consistent with the principles advanced in IEC 60695-7-3, and ISO/TR 9122-5. It is designed specifically to make use of results in the form expressed in the laboratory test method described in IEC 60695-7-50.Toxic potency values are only of use in toxic hazard estimations, and must not be used in isolation.Has the status of a basic safety publication in accordance with IEC Guide 104.
DevelopmentNote |
To be used in conjunction with IEC 60695-7-50. (09/2002) Stability Date: 2017. (10/2012)
|
DocumentType |
Technical Specification
|
Pages |
27
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
SAC GB/T 5169.41 : 2015 | Identical |
NEN NPR IEC/TS 60695-7-51 : 2002 | Identical |
DD IEC/TS 60695-7-51:2002 | Identical |
AS 60695.7.51-2006 | Identical |
13/30275218 DC : 0 | BS ISO 19700 - CONTROLLED EQUIVALENCE RATIO METHOD FOR THE DETERMINATION OF HAZARDOUS COMPONENTS OF FIRE EFFLUENTS - THE STEADY STATE TUBE FURNACE |
EN 60695-7-2:2011 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
I.S. EN 60695-7-2:2011 | FIRE HAZARD TESTING - PART 7-2: TOXICITY OF FIRE EFFLUENT - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-7-2:2011) |
IEC 60695-7-2:2011 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
CEI EN 60695-7-2 : 2013 | FIRE HAZARD TESTING - PART 7-2: TOXICITY OF FIRE EFFLUENT - SUMMARY AND RELEVANCE OF TEST METHODS |
ISO/TR 16312-2:2007 | Guidance for assessing the validity of physical fire models for obtaining fire effluent toxicity data for fire hazard and risk assessment Part 2: Evaluation of individual physical fire models |
IEC TS 60695-7-50:2002 | Fire hazard testing - Part 7-50: Toxicity of fire effluent - Estimation of toxic potency - Apparatus and test method |
IEC 61196-4:2015 | Coaxial communication cables - Part 4: Sectional specification for radiating cables |
BS EN 60695-7-2:2011 | Fire hazard testing Toxicity of fire effluent. Summary and relevance of test methods |
UNE-EN 60695-7-2:2012 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
PD IEC TR 60695-7-2:2002 | Fire hazard testing. Toxicity of fire effluent Summary and relevance of test methods |
IEC TR 60695-7-2:2002 | Fire hazard testing - Part 7-2: Toxicity of fire effluent - Summary and relevance of test methods |
ISO/TR 9122-1:1989 | Toxicity testing of fire effluents Part 1: General |
ISO 13344:2015 | Estimation of the lethal toxic potency of fire effluents |
ISO/TR 9122-5:1993 | Toxicity testing of fire effluents Part 5: Prediction of toxic effects of fire effluents |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60695-7-1:2010 | Fire hazard testing - Part 7-1: Toxicity of fire effluent - General guidance |
IEC TS 60695-7-3:2004 | Fire hazard testing - Part 7-3: Toxicity of fire effluent - Use and interpretation of test results |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.