IEC TR 62685:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Industrial communication networks - Profiles - Assessment guideline for safety devices using IEC 61784-3 functional safety communication profiles (FSCPs)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-31-2021
English, English - French
12-08-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 General
5 Test bed and operations
6 General test conditions
7 Climatic tests
8 Mechanical tests
9 Markings and identification
10 User manual
11 Electromagnetic immunity
12 Electrical safety
13 Suitability of components
14 Simple circumvention
15 Explosive atmosphere
16 Field verification(process automation devices)
Annex A (informative) - Comparison of immunity levels
in several IEC standards
Annex B (informative) - Product, sector and application
specific requirements
Bibliography
IEC/TR 62685:2010 provides information about the assessment aspects of safe communication such as test beds, proof of increased interference immunity (EMC for functional safety), electrical safety, and other environmental requirements. It is only applicable to safety devices for functional safety communication which are developed according to IEC 61508 and IEC 61784-3 and covers general industrial environments such as defined in IEC 61131-2 or IEC 61000-6-2 and process automation environments such as those covered in the IEC 61326 series. Reference is made to the ERS (Equipment Requirements Specification) and/or SRS (Safety Requirements Specification) of a particular safety application to verify the necessary immunity of devices and systems according to IEC 61508. This bilingual version (2013-04) corresponds to the monolingual English version, published in 2010-12.
Committee |
TC 65/SC 65C
|
DevelopmentNote |
A Bilingual edition has been published. (04/2013) Stability date: 2017. (09/2017)
|
DocumentType |
Technical Report
|
Pages |
29
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
BS PD IEC TR 62685 : 2010 | Identical |
DIN EN 61784-3 SUPP 1 : 2012 | Identical |
CEI CLC/TR 62685 : 2012 | Identical |
NEN NPR CLC IEC/TR 62685 : 2011 | Identical |
VDE 0803-500 SUPP 1 : 2012 | Identical |
PD CLC/TR 62685:2011 | Identical |
CLC/TR 62685:2011 | Identical |
12/30264901 DC : 0 | BS EN 61158-1 - INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 1: OVERVIEW AND GUIDANCE FOR THE IEC 61158 AND IEC 61784 SERIES |
BS EN 61784-3-2:2017 | Industrial communication networks. Profiles Functional safety fieldbuses. Additional specifications for CPF 2 |
EN 61784-3-3:2017 | Industrial communication networks - Profiles - Part 3-3: Functional safety fieldbuses - Additional specifications for CPF 3 |
I.S. EN 61158-1:2014 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 1: OVERVIEW AND GUIDANCE FOR THE IEC 61158 AND IEC 61784 SERIES |
I.S. EN 61784-3-17:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-17: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 17 |
BS EN 61784-3:2010 | Industrial communication networks. Profiles Functional safety fieldbuses. General rules and profile definitions |
IEC 61784-3-3:2016 | Industrial communication networks - Profiles - Part 3-3: Functional safety fieldbuses - Additional specifications for CPF 3 |
EN 61784-3:2016/A1:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS (IEC 61784-3:2016/A1:2017) |
I.S. EN 61784-3:2016 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS |
EN 61784-3-8:2017 | Industrial communication networks - Profiles - Part 3-8: Functional safety fieldbuses - Additional specifications for CPF 8 |
I.S. EN 61784-3-3:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-3: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 3 |
IEC 61784-3:2016 RLV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
EN 61784-3-17:2017 | Industrial communication networks - Profiles - Part 3-17: Functional safety fieldbuses - Additional specifications for CPF 17 |
I.S. EN 61784-3-2:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-2: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 2 |
I.S. EN 61784-3-13:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-13: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 13 |
IEC 61784-3-8:2016 | Industrial communication networks - Profiles - Part 3-8: Functional safety fieldbuses - Additional specifications for CPF 8 |
13/30294106 DC : 0 | BS EN 61784-3 ED 3.0 - INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS |
BS EN 61158-1:2014 | Industrial communication networks. Fieldbus specifications Overview and guidance for the IEC 61158 and IEC 61784 series |
BS EN 61784-3-3:2017 | Industrial communication networks. Profiles Functional safety fieldbuses. Additional specifications for CPF 3 |
IEC 61784-3-17:2016 | Industrial communication networks - Profiles - Part 3-17: Functional safety fieldbuses - Additional specifications for CPF 17 |
EN 61784-3-2:2017 | Industrial communication networks - Profiles - Part 3-2: Functional safety fieldbuses - Additional specifications for CPF 2 |
I.S. EN 61784-3-8:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-8: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 8 |
IEC 61784-3-2:2016 | Industrial communication networks - Profiles - Part 3-2: Functional safety fieldbuses - Additional specifications for CPF 2 |
IEC 61784-3-13:2016 | Industrial communication networks - Profiles - Part 3-13: Functional safety fieldbuses - Additional specifications for CPF 13 |
EN 61784-3-13:2017 | Industrial communication networks - Profiles - Part 3-13: Functional safety fieldbuses - Additional specifications for CPF 13 |
IEC 61784-3:2016+AMD1:2017 CSV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
EN 61158-1:2014 | Industrial communication networks - Fieldbus specifications - Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
ISA TR84.00.02 PTS 1-5 : 2002 | SAFETY INSTRUMENTED FUNCTIONS (SIF) - SAFETY INTEGRITY LEVEL (SIL) - EVALUATION TECHNIQUES PACKAGE |
IEC 61326-3-2:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
IEC 61000-6-7:2014 | Electromagnetic compatibility (EMC) - Part 6-7: Generic standards - Immunity requirements for equipment intended to perform functions in a safety-related system (functional safety) in industrial locations |
IEC 61511-1:2016+AMD1:2017 CSV | Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and application programming requirements |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
ISA 84.00.01-1 : 2004 | FUNCTIONAL SAFETY: SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRY SECTOR - PART 1: FRAMEWORK, DEFINITIONS, SYSTEM, HARDWARE AND SOFTWARE REQUIREMENTS |
IEC TS 61000-1-2:2008 | Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
NAMUR NE 130 : 2011 | 'PRIOR USE'-DEVICES FOR SAFETY INSTRUMENTED SYSTEMS AND SIMPLIFIED SIL CALCULATION |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 14459:2015 | Safety and control devices for burners and appliances burning gaseous or liquid fuels - Control functions in electronic systems - Methods for classification and assessment |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
IEC 61511-3:2016 | Functional safety - Safety instrumented systems for the process industry sector - Part 3: Guidance for the determination of the required safety integrity levels |
NFPA 86 : 2015 | OVENS AND FURNACES |
NFPA 85 : 2015 | BOILER AND COMBUSTION SYSTEMS HAZARDS CODE |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISA 84.00.01-3 : 2004 | FUNCTIONAL SAFETY: SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRY SECTOR - PART 3: GUIDANCE FOR THE DETERMINATION OF THE REQUIRED SAFETY INTEGRITY LEVELS - INFORMATIVE |
IEC 61511-2:2016 | Functional safety - Safety instrumented systems for the process industry sector - Part 2: Guidelines for the application of IEC 61511-1:2016 |
IEC 61496-1:2012 | Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 954-1 : 1996 | SAFETY OF MACHINERY - SAFETY-RELATED PARTS OF CONTROL SYSTEMS - PART 1: GENERAL PRINCIPLES FOR DESIGN |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
ISO/IEC 2382-14:1997 | Information technology Vocabulary Part 14: Reliability, maintainability and availability |
EN 298:2012 | Automatic burner control systems for burners and appliances burning gaseous or liquid fuels |
ISO/IEC 2382-16:1996 | Information technology Vocabulary Part 16: Information theory |
ISA 84.00.01-2 : 2004 | FUNCTIONAL SAFETY: SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRY SECTOR - PART 2: GUIDELINES FOR THE APPLICATION OF ANSI/ISA-84.00.01 - PART 1 - INFORMATIVE |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV | Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
IEC 61800-5-2:2016 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
IEC 61326-3-1:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications |
IEC 61784-3:2016+AMD1:2017 CSV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
IEC 60721-3-1:1997 | Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.