IEC TR 62153-4-1:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic (EMC) screening measurements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-22-2014
English
05-12-2010
FOREWORD
1 Scope
2 Normative references
3 Electromagnetic phenomena
4 The intrinsic screening parameters of short cables
5 Long cables - coupled transmission lines
6 Transfer impedance of a braided wire outer conductor
or screen
7 Test possibilities
8 Comparison of the frequency response of different
triaxial test set-ups to measure the transfer impedance
of cable screens
9 Background of the shielded screening attenuation test
method (IEC 62153-4-4)
Annex A (normative) - List of symbols
Bibliography
IEC/TR 62153-4-1:2010(E) gives a brief introduction to basic concepts and terms trying to reveal the common features of apparently different test methods. It should assist in correct interpretation of test data, and in the better understanding of screening (or shielding) and related specifications and standards. This second edition cancels and replaces the first edition published in 2007. The significant change is a new clause on the background of the shielded screening attenuation test method.
This publication contains colours which are considered to beuseful for the correct understanding of its contents.
Committee |
TC 46
|
DevelopmentNote |
Supersedes IEC 61917. (11/2007) Stability Date: 2013. (10/2012)
|
DocumentType |
Technical Report
|
Pages |
72
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
PD IEC TS 62153-4-1:2014+A1:2020 | Identical |
PD IEC/TR 62153-4-1:2010 | Identical |
NEN NPR IEC/TR 62153-4-1 : 2010 | Identical |
08/30182556 DC : DRAFT MAY 2008 | BS EN 62153-4-11 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-11: ELECTROMAGNETIC COMPATIBILITY (EMC) - COUPLING ATTENUATION OR SCREENING ATTENUATION OF PATCH CORDS/COAXIAL CABLE ASSEMBLIES/PRE-CONNECTORISED CABLES ABSORBING CLAMP METHOD |
IEC 62153-4-14:2012 | Metallic communication cable test methods - Part 4-14: Electromagnetic compatibility (EMC) - Coupling attenuation of cable assemblies (Field conditions) absorbing clamp method |
BS IEC 62153-4-3:2013 | Metallic communication cable test methods Electromagnetic compatibility (EMC). Surface transfer impedance. Triaxial method |
08/30182560 DC : DRAFT MAY 2008 | BS EN 62153-4-12 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-12: ELECTROMAGNETIC COMPATIBILITY (EMC) - COUPLING ATTENUATION OR SCREENING ATTENUATION OF CONNECTING HARDWARE - ABSORBING CLAMP METHOD |
IEC 62153-4-3:2013 | Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method |
11/30247112 DC : 0 | BS EN 62153-4-3 ED.2 - METALIC COMMUNICATION CABLE TEST METHODS - PART 4-3: ELECTROMAGNETIC COMPATABILITY (EMC) - SURFACE TARNSFER IMPEDANCE - TRIAXIAL METHOD |
08/30182564 DC : DRAFT MAY 2008 | BS EN 62153-4-13 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-13: ELECTROMAGNETIC COMPATIBILITY (EMC) - COUPLING ATTENUATION OF LINKS AND CHANNELS (LABORATORY CONDITIONS) ABSORBING CLAMP METHOD |
13/30279876 DC : 0 | BS EN 62153-4-15 ED.1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-15: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING TRANSFER IMPEDANCE AND SCREENING ATTENUATION - OR COUPLING ATTENUATION WITH TRIAXIAL CELL |
13/30292984 DC : 0 | BS EN 62153-4-10 ED2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-10: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE SCREENING EFFECTIVENESS OF FEED-THROUGHS AND ELECTROMAGNETIC GASKETS DOUBLE COAXIAL METHOD |
13/30283920 DC : 0 | BS EN 62153-4-7 ED.2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE TRANSFER IMPEDANCE Z[T] AND THE SCREENING ATTENUATION A[S] OR THE COUPLING ATTENUATION A[C] OF RF-CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ; TUBE |
IEC 62153-4-3:2013 | Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method |
EN 50289-1-6:2002 | Communication cables - Specifications for test methods - Part 1-6: Electrical test methods - Electromagnetic performance |
IEC 62153-4-4:2015 | Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method |
IEC 60169-1-3:1988 | Radio-frequency connectors - Part 1: General requirements and measuring methods - Section Three: Electrical tests and measuring procedures: Screening effectiveness |
IEC 61196-1:2005 | Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements |
IEC 62153-4-5:2006 | Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method |
IEC 60096-4-1:1990 | Radio-frequency cables. Part 4: Specification for superscreened cables - Section One: General requirements and test methods |
IEC 61726:2015 | Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.