FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Technical information (electrical ratings)
5 Classification
6 Requirements
7 Tests
Annex A (informative) - Additional characteristics
to be agreed by the manufacturer and the user
Annex B (normative) - Severity of the service
conditions in different rolling stock locations
(mandatory)
Annex C (informative) - Severity of the service
conditions in different rolling stock
locations (optional)
Bibliography
IEC 62847:2016 retains IEC 61984:2008 as the minimum performance requirements for railway rolling stock electrical connectors and identifies additional terms, test methods and performance requirements for single-pole and multipole connectors with rated voltages up to 1 000 V, rated currents up to 125 A per contact and frequencies below 3 MHz used for indoor and outdoor applications in railway rolling stock.
DevelopmentNote |
Stability date: 2019. (02/2016)
|
DocumentType |
Standard
|
Pages |
96
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
DS IEC 62847 : 2016 | Identical |
DS/EN IEC 62847:2023 | Identical |
PN-EN IEC 62847:2024-01 | Identical |
VDE 0115-847:2023-11 | Identical |
DIN EN IEC 62847:2023-11 | Identical |
CEI EN IEC 62847:2023 | Identical |
UNE-EN IEC 62847:2023 | Identical |
IEC 62888-1:2018 | Railway applications - Energy measurement on board trains - Part 1: General |
IEC 62973-1:2018 | Railway applications - Rolling stock - Batteries for auxiliary power supply systems - Part 1: General requirements |
IEC 60512-23-7:2005 | Connectors for electronic equipment - Tests and measurements - Part 23-7: Screening and filtering tests - Test 23g: Effective transfer impedance of connectors |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
EN 50264-2-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
IEC 60068-2-70:1995 | Environmental testing - Part 2-70: Tests - Test Xb: Abrasion of markings and letterings caused by rubbing of fingers and hands |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60512-11-9:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-9: Climatic tests - Test 11i: Dry heat |
IEC 60512-11-10:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-10: Climatic tests - Test 11j: Cold |
EN 50306-1:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 50264-3-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
IEC 60512-6:1984 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 6: Climatic tests and soldering tests |
EN 50382-2:2008/A1:2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60512-13-5:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-5: Mechanical operation tests - Test 13e: Polarizing and keying method |
IEC 60512-15-1:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-1: Connector tests (mechanical) - Test 15a: Contact retention in insert |
EN 50264-2-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
IEC 60512-1-4:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 1: General - Section 4: Test 1d: Contact protection effectiveness (scoop-proof) |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60512-7:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 7: Mechanical operating tests and sealing tests |
IEC 60512-11-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-2: Climatic tests - Test 11b: Combined/sequential cold, low air pressure and damp heat |
IEC 60512-15-3:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-3: Connector tests (mechanical) - Test 15c: Insert retention in housing (torsional) |
EN 45545-1 : 2013 COR 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
IEC 60512-5-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-1: Current-carrying capacity tests - Test 5a: Temperature rise |
IEC 60512-2-5:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resistance tests - Test 2e: Contact disturbance |
IEC 60512-15-2:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-2: Connector tests (mechanical) - Test 15b: Insert retention in housing (axial) |
EN 50382-1 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
EN 50264-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements |
IEC 60352-1:1997 | Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance |
IEC 60512-2-2:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-2: Electrical continuity and contact resistance tests - Test 2b: Contact resistance - Specified test current method |
ISO 1431-1:2012 | Rubber, vulcanized or thermoplastic Resistance to ozone cracking Part 1: Static and dynamic strain testing |
IEC 60077-2:2017 | Railway applications - Electric equipment for rolling stock - Part 2: Electrotechnical components - General rules |
IEC 60512-11-3:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-3: Climatic tests - Test 11c: Damp heat, steady state |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
EN 50306-4:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed |
IEC 61991:2000 | Railway applications - Rolling stock - Protective provisions against electrical hazards |
IEC 60571:2012 | Railway applications - Electronic equipment used on rolling stock |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-23-4:2001 | Connectors for electronic equipment - Tests and measurements - Part 23-4: Screening and filtering tests - Test 23d: Transmission line reflections in the time domain |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
IEC 60512-5-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 5-2: Current-carrying capacity tests - Test 5b: Current-temperature derating |
IEC 60512-19-3:1997 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 19: Chemical resistance tests - Section 3: Test 19c - Fluid resistance |
EN 50264-3-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
EN 50306-2:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60512-9:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 9: Miscellaneous tests |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
IEC 60512-11-6:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-6: Climatic tests - Test 11f: Corrosion, salt mist |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 50306-3:2002 | Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60512-5:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60512-23-3:2000 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 23-3: Test 23c: Shielding effectiveness of connectors and accessories |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60077-1:2017 | Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules |
EN 45545-5:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 5: Fire safety requirements for electrical equipment including that of trolley buses, track guided buses and magnetic levitation vehicles |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
IEC 62498-1:2010 | Railway applications - Environmental conditions for equipment - Part 1: Equipment on board rolling stock |
IEC 60512-13-1:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-1: Mechanical operation tests - Test 13a: Engaging and separating forces |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.