IEC 62620:2014
Current
The latest, up-to-date edition.
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for use in industrial applications
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
11-25-2014
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Parameters measurement tolerances
5 Marking and designation
6 Electrical tests
7 Type test conditions
Annex A (informative) - Battery structure information
Bibliography
IEC 62620:2014 specifies marking, tests and requirements for lithium secondary cells and batteries used in industrial applications including stationary applications. When there exists an IEC standard specifying test conditions and requirements for cells used in special applications and which is in conflict with this standard, the former takes precedence. (e.g. IEC 62660 series on road vehicles). The following are some examples of applications that utilize the cells and batteries under the scope of this standard.
- Stationary applications: telecom, uninterruptible power supplies (UPS), electrical energy storage system, utility switching, emergency power and similar applications.
- Motive applications: fork-lift truck, golf cart, AGV, railway, and marine, excluding road vehicles.
This standard applies to cells and batteries. If the battery is divided into smaller units, the smaller unit can be tested as the representative of the battery. The manufacturer clearly declares the tested unit. The manufacturer may add functions, which are present in the final battery, to the tested unit.
Committee |
TC 21/SC 21A
|
DevelopmentNote |
Stability date: 2017. (12/2014)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
GOST R IEC 62620 : 2016 | Identical |
NF EN 62620 : 2015 | Identical |
NBN EN 62620 : 2015 | Identical |
NEN EN IEC 62620 : 2015 | Identical |
PN EN 62620 : 2015 | Identical |
VDE 0510-35 : 2015 | Identical |
DIN EN 62620 : 2015 | Identical |
BS EN 62620:2015 | Identical |
CEI EN 62620 : 2016 | Identical |
EN 62620:2015 | Identical |
OVE/ONORM EN 62620 : 2015 | Identical |
UNE-EN 62620:2015 | Identical |
PNE-FprEN 62620 | Identical |
BS EN 61427-2:2015 | Secondary cells and batteries for renewable energy storage. General requirements and methods of test On-grid applications |
16/30296073 DC : 0 | BS EN 62924 ED 1.0 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - STATIONARY ENERGY STORAGE SYSTEM FOR DC TRACTION SYSTEMS |
12/30243533 DC : 0 | BS EN 61427-2 ED 1.0 - SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 2: ON-GRID APPLICATIONS |
BS EN 62924:2017 | Railway applications. Fixed installations. Stationary energy storage system for DC traction systems |
I.S. EN IEC 62933-2-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
17/30338554 DC : 0 | BS EN 1175 - SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS |
16/30350625 DC : 0 | BS EN 62485-5 ED 1.0 - SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 5: LITHIUM-ION BATTERIES FOR STATIONARY APPLICATIONS |
IEC 62864-1:2016 | Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system |
EN 61427-1 : 2013 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION (IEC 61427-1:2013) |
15/30288088 DC : DRAFT FEB 2015 | BS EN 62864-1 ED 1.0 - RAILWAY APPLICATIONS - ROLLING STOCK - POWER SUPPLY WITH ONBOARD ENERGY STORAGE SYSTEM - PART 1: SERIES HYBRID SYSTEM |
IEEE 1679.1-2017 | IEEE Guide for the Characterization and Evaluation of Lithium-Based Batteries in Stationary Applications |
IEC 62928:2017 | Railway applications - Rolling stock - Onboard lithium-ion traction batteries |
I.S. EN 61427-1:2013 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION (IEC 61427-1:2013 (EQV)) |
EN IEC 62928:2018 | Railway applications - Rolling stock - Onboard lithium-ion traction batteries |
17/30354643 DC : 0 | BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
13/30293679 DC : 0 | BS EN 62619 - SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON-ACID ELECTROLYTES - SAFETY REQUIREMENTS FOR SECONDARY LITHIUM CELLS AND BATTERIES, FOR USE IN INDUSTRIAL APPLICATIONS |
CAN/CSA-C61427-1:17 | Secondary cells and batteries for renewable energy storage — General requirements and methods of test — Part 1: Photovoltaic off-grid application (Adopted IEC 61427-1:2013, first edition, 2013-04, with Canadian deviations) | Accumulateurs pour le stockage de l’énergie renouvelable — Exigences générales et méthodes d’essais — Partie 1 : Applications photovoltaïques hors réseaux (norme IEC 61427-1:2013 adoptée, première édition, 2013-04, avec exigences propres au Canada) |
EN IEC 62933-2-1:2018 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
EN 62924:2017 | Railway applications - Fixed installations - Stationary energy storage system for DC traction systems |
I.S. EN 62619:2017 | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON-ACID ELECTROLYTES - SAFETY REQUIREMENTS FOR SECONDARY LITHIUM CELLS AND BATTERIES, FOR USE IN INDUSTRIAL APPLICATIONS |
ES 202 336-11 : 1.1.1 | ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 11: BATTERY SYSTEM WITH INTEGRATED CONTROL AND MONITORING INFORMATION MODEL |
IEC 62619:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications |
IEC 62933-2-1:2017 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
PREN 1175 : DRAFT 2017 | SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS |
BS EN 61427-1:2013 | Secondary cells and batteries for renewable energy storage. General requirements and methods of test Photovoltaic off-grid application |
I.S. EN 61427-2:2015 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 2: ON-GRID APPLICATIONS |
EN 62619:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications |
I.S. EN 62864-1:2016 | RAILWAY APPLICATIONS - ROLLING STOCK - POWER SUPPLY WITH ONBOARD ENERGY STORAGE SYSTEM - PART 1: SERIES HYBRID SYSTEM |
UNE-EN 62924:2017 | Railway applications - Fixed installations - Stationary energy storage system for DC traction systems |
UNE-EN 62864-1:2017 | Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system |
CEI EN 61427-1 : 2014 | SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION |
16/30350629 DC : 0 | BS EN 62485-6 ED 1.0 - SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 6: LITHIUM-ION BATTERIES FOR TRACTION APPLICATIONS |
IEC 61427-1:2013 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 1: Photovoltaic off-grid application |
IEC 61427-2:2015 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications |
BS EN 62619:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes. Safety requirements for secondary lithium cells and batteries, for use in industrial applications |
CEI EN 62619 : 1ED 2017 | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NONACID ELECTROLYTES - SAFETY REQUIREMENTS FOR SECONDARY LITHIUM CELLS AND BATTERIES, FOR USE IN INDUSTRIAL APPLICATIONS |
I.S. EN 62924:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - STATIONARY ENERGY STORAGE SYSTEM FOR DC TRACTION SYSTEMS |
I.S. EN IEC 62928:2018 | RAILWAY APPLICATIONS - ROLLING STOCK - ONBOARD LITHIUM-ION TRACTION BATTERIES |
IEC 62924:2017 | Railway applications - Fixed installations - Stationary energy storage system for DC traction systems |
EN 62864-1:2016 | Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system |
EN 61427-2:2015 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications |
IEC 61960:2011 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications |
IEC 60485:1974 | Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital converters |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 61434:1996 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Guide to designation of current in alkaline secondary cell and battery standards |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.