FOREWORD
1 Scope and object
2 Normative references
3 Terms and definitions
4 Classification of tritium monitoring equipment
4.1 General design considerations
4.2 Methods of detection
4.3 Ease of decontamination
4.4 Considerations for explosive mixtures
4.5 Corrosion resistance
4.6 Reliability
4.7 Capability of operational testing
4.8 Adjustment and maintenance facilities
4.9 Acoustic noise level of the assembly
4.10 Electromagnetic interference
4.11 Mechanical shock
4.12 Measurement characteristics
4.13 Measurement range
5 Equipment components
5.1 General
5.2 Sampling assembly
5.3 Detection assembly
5.4 Control assembly
5.5 Indication facilities
5.6 Alarm assembly
5.7 Check source
5.8 Ambient background shielding or compensation devices
5.9 Batteries
6 Test conditions
6.1 General test procedures
6.2 Tests performed under standard test conditions for
normal operation condition
6.3 Tests performed with variation of influence quantities
6.4 Tests performed under test conditions for emergency
conditions
6.5 Types of sources
6.6 Metrological confirmation system during tests
7 Radiation detection tests
7.1 General
7.2 Reference response
7.3 Linearity
7.4 Response to other chemical forms of tritium
7.5 Response to radioactive gases other than tritium
7.6 Response time
7.7 Response to ambient gamma radiation
7.8 Response to neutron radiation
7.9 Overload test
7.10 Repeatability
7.11 Stability of background indication
7.12 Reproducibility of the indication
8 Electrical and mechanical tests
8.1 Alarm trip range
8.2 Alarm trip stability
8.3 Equipment fault alarms
8.4 Warm-up time - detection and measurement assembly
8.5 Power supply variations
8.6 Battery test
8.7 Power supply transient effects
9 Air circuit performance test
9.1 General
9.2 Susceptibility to gaseous retention
9.3 Accuracy of the volume and flow rate measurement
9.4 Flow rate stability
9.5 Effect of filter pressure drop
9.6 Effect of power supply voltage on the flow rate
9.7 Effect of power supply frequency on flow rate
10 Environmental performance tests
10.1 Ambient temperature
10.2 Temperature shock
10.3 Relative humidity
10.4 Atmospheric pressure
10.5 Sealing
10.6 Mechanical shock
10.7 External electromagnetic immunity and electrostatic
discharge
10.8 Electromagnetic emission
11 Type test report and certificate
12 Operation and maintenance manual
Annex A (informative) General information on conditions of
operation
Annex B (informative) Preparation of tritiated radioactive
reference sources
IEC 62303:2008 is applicable to equipment used for sampling and continuous measurement of tritium in the workplace, in gaseous effluents discharged into the environment as well as in the environment itself and it is applicable to installed, portable and transportable equipment. The object is to establish mandatory general requirements and to present examples of acceptable methods and equipment for continuously monitoring and/or sampling airborne tritium. Complements IEC 60761-5.
DevelopmentNote |
Supersedes IEC 60710. (12/2008) Stability Date: 2015. (10/2012)
|
DocumentType |
Standard
|
Pages |
94
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SAC GB/T 30150 : 2013 | Identical |
NEN IEC 62303 : 2008 | Identical |
DIN IEC 62303 : 2010 | Identical |
CEI IEC 62303 : 2019 | Identical |
VDE 0493-1-50 : 2010 | Identical |
16/30324061 DC : 0 | BS IEC 61504 ED2.0 - NUCLEAR FACILITIES INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - CENTRALIZED SYSTEMS FOR CONTINUOUS MONITORING OF RADIATION AND/OR LEVELS OF RADIOACTIVITY |
I.S. EN 62506:2013 | METHODS FOR PRODUCT ACCELERATED TESTING (IEC 62506:2013 (EQV)) |
CSA N288.5 : 2011 : R2016 | EFFLUENT MONITORING PROGRAMS AT CLASS 1 NUCLEAR FACILITIES AND URANIUM MINES AND MILLS |
EN 62506 : 2013 | METHODS FOR PRODUCT ACCELERATED TESTING (IEC 62506:2013) |
BS EN 62506:2013 | Methods for product accelerated testing |
BS IEC 62705:2014 | Nuclear power plants. Instrumentation and control important to safety. Radiation monitoring systems (RMS): Characteristics and lifecycle |
13/30249610 DC : 0 | BS EN 62705 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEMS (RMS) CHARACTERISTICS AND TEST METHODS |
IEEE N323C-2009 | American National Standard Radiation Protection Instrumentation Test and Calibration - Air Monitoring Instruments |
CEI EN 62506 : 2014 | METHODS FOR PRODUCT ACCELERATED TESTING |
BS IEC 61504:2017 | Nuclear facilities. Instrumentation and control systems important to safety. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
DEFSTAN 05-55(PT3)/2(2016) : 2016 | MEASUREMENT AND CALIBRATION SYSTEM REQUIREMENTS FOR MINISTRY OF DEFENCE TEST AND MEASUREMENT EQUIPMENT - PART 3: SUB CONTRACT OF CALIBRATION |
CSA N288.5 : 2011 | EFFLUENT MONITORING PROGRAMS AT CLASS 1 NUCLEAR FACILITIES AND URANIUM MINES AND MILLS |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
IEC 62506:2013 | Methods for product accelerated testing |
ANSI N42.54 : 2018 | INSTRUMENTATION AND SYSTEMS FOR MONITORING AIRBORNE RADIOACTIVITY |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 60761-5:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 5: Specific requirements for tritium monitors |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
ISO/IEC Guide 98:1993 | Guide to the expression of uncertainty in measurement (GUM) |
ISO 2889:2010 | Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
IEC 60761-1:2002 | Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 1: General requirements |
IEC 60050-393:2003 | International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts |