• Shopping Cart
    There are no items in your cart

IEC 62271-111:2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

02-20-2019

Superseded by

IEC 62271-111:2019

Language(s)

English

Published date

09-25-2012

US$515.00
Excluding Tax where applicable

FOREWORD
1 Overview
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of switchgear
   and controlgear
9 Information to be given with enquiries,
   tenders and orders
10 Transport, storage, installation, operation
   and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - X/R Ratios
Annex B (informative) - Simulated surge
        arrester operation test
Annex C (normative) - Method of drawing the
        envelope of the prospective transient
        recovery voltage of a circuit and determining
        the representative parameters
Annex D (informative) - Background basis of recloser
        TRV values
Annex E (normative) - Tolerances for test values
Annex F (informative) - Definition for the automatic
        circuit recloser
Annex G (informative) - Definition for the fault
        interrupter
Annex H (informative) - Basis of derivation of duty
        factors and standard operating duties
Annex I (normative) - Ratings for oil interrupting
        reclosers and hydraulically controlled
        reclosers
Annex J (normative) - Standard methods for determining
        the values of a sinusoidal current wave and a
        power-frequency recovery voltage
Annex K (normative) - Altitude correction factors
Annex L (informative) - Comparison of definitions
        related to the unit operation
Annex M (informative) - Corrosion protection
Bibliography

IEC 62271-111:2012(E) applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1 000 V and up to 38 kV. This second edition cancels and replaces the first edition, published in 2005, and constitutes a technical revision. The main changes with respect to the previous edition are as follows:
a) addition of exclusion of devices with dependent manual operation to 1.1;
b) harmonization of the amplitude factor kaf used for calculating the TRV for cable connected systems consistent with recent harmonization of the circuit-breaker standards between IEEE and IEC;
c) deletion of requirements for radio influence voltage (RIV) tests;
d) addition of specifications and ratings to cover the cutout recloser and its special requirements.
This standard has been jointly revised by Switchgear Committee of the IEEE Power and Energy Society, in cooperation with subcommittee 17A: High-voltage switchgear and controlgear with reference to IEEE Std C37.60-2012(E).

This publication is to be read in conjunction with IEC 62271-1:2007.

Committee
TC 17/SC 17A
DevelopmentNote
Also numbered as IEEE C37.60. (11/2005) To be read in conjunction with IEC 62271-1. (09/2012) Stability Date: 2015. (10/2012)
DocumentType
Standard
Pages
129
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NEN IEC 62271-111 : 2012 Identical
BS EN 60454-3-11:2007 Identical

IEEE 1584-2002 IEEE Guide for Performing Arc Flash Hazard Calculations
I.S. EN IEC 62271-100:2021+AC:2024-02 High-voltage switchgear and controlgear - Part 100: Alternatingcurrent circuit-breakers (IEC 62271-100:2021/COR3:2024)

IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 60255-22-1:2007 Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEEE C37.90-2005 IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
IEEE C37.100.1-2007 IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V
IEC 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
IEEE 386-2016 IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
CSA C22.2 No. 31 : 2014 SWITCHGEAR ASSEMBLIES
IEEE 400.2-2013 REDLINE IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)
IEEE C37.04B : 2008 RATING STRUCTURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 2: TO CHANGE THE DESCRIPTION OF TRANSIENT RECOVERY VOLTAGE FOR HARMONIZATION WITH IEC 62271-100
IEC TS 62271-304:2008 High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
IEEE C37.90.3-2001 IEEE Standard Electrostatic Discharge Tests for Protective Relays
ANSI C37.85 : 1989 ALTERNATING-CURRENT HIGH-VOLTAGE POWER VACUUM INTERRUPTERS - SAFETY REQUIREMENTS FOR X-RADIATION LIMITS
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEEE C57.12.29-2014 IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity for Coastal Environments
IEC 60255-22-6:2001 Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields
IEEE C37.40-2003 IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
IEC 60255-22-3:2007 Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC TR 60943:1998+AMD1:2008 CSV Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals
IEEE C37.90.2:2004 WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS
IEC 62208:2011 Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements
IEEE C37.90.1-2012 IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
IEC 60255-22-2:2008 Measuring relays and protection equipment - Part 22-2: Electrical disturbance tests - Electrostatic discharge tests
IEC 60255-151:2009 Measuring relays and protection equipment - Part 151: Functional requirements for over/under current protection
IEEE C37.20.7-2007 REDLINE IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEEE C57.12.31-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity
IEEE C37.24-2003 IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
IEEE C37.41-2008 REDLINE IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60050-448:1995 International Electrotechnical Vocabulary (IEV) - Part 448: Power system protection
IEEE C57.12.28-2014 IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity
IEC 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
IEEE C37.06-2009 IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V
IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations
IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches
IEC 60255-22-4:2008 Measuring relays and protection equipment - Part 22-4: Electrical disturbance tests - Electrical fast transient/burst immunity test

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.