INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Identification
5 Environmental conditions
6 Information on transport, storage and installation
7 Classification of tests
   7.1 Design tests
   7.2 Type tests
   7.3 Sample tests
   7.4 Routine tests
8 Design tests
   8.1 General
   8.2 Tests on interfaces and connections of end fittings
   8.3 Assembled core load tests
   8.4 Tests on shed and housing material
   8.5 Tests on the core material
9 Type tests
   9.1 Verification of dimensions
   9.2 Electrical tests
   9.3 Mechanical tests
10 Sample tests
   10.1 General rules
   10.2 Verification of dimensions (E1 + E2)
   10.3 Galvanizing test (E1 + E2)
   10.4 Verification of the specified mechanical loads (E1)
   10.5 Re-testing procedure
11 Routine tests
   11.1 Identification of the station post insulator
   11.2 Visual examination
   11.3 Tensile load test
Annex A (informative) Notes on the mechanical loads and tests
Annex B (informative) Determination of the equivalent bending
                      moment caused by combined cantilever and
                      compression (tension) loads
Annex C (informative) Example of torsion load test arrangement
Annex D (normative) Tolerances of form and position
Annex E (informative) Notes on the compression and buckling test
Bibliography

This International Standard applies to composite station post insulators consisting of a load bearing cylindrical insulating solid core made of resin impregnated fibres, a housing (outside the insulating solid core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings attached to the insulating core. Composite station post insulators covered by this standard are subjected to cantilever, torsion, tension and compression loads. They are intended for substations with a.c. voltages greater than 1 000 V up to 245 kV.

Committee
TC 36
DevelopmentNote
To be read in conjunction with IEC 62217. (02/2006) A Bilingual edition has been published. (04/2006) Stability Date: 2019. (09/2017)
DocumentType
Standard
Pages
33
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
NF EN 62231 : 2007 Identical
NEN EN IEC 62231 : 2007 Identical
I.S. EN 62231:2007 Identical
PN EN 62231 : 2008 Identical
AS 62231-2007 Identical
DIN EN 62231 : 2007 Identical
VDE 0674-7 : 2007 Identical
BS EN 62231:2007 Identical
UNE-EN 62231:2007 Identical
CEI EN 62231 : 2007 Identical
EN 62231:2006 Identical

CEI EN 62271-207 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
I.S. EN 60505:2011 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS
NF EN 62231-1 : 2016 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH AC VOLTAGES GREATER THAN 1000 V UP TO 245 KV - PART 1: DIMENSIONAL, MECHANICAL AND ELECTRICAL CHARACTERISTICS
EN 60505:2011/AC:2017-03 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017)
13/30257235 DC : 0 BS EN 62772 - COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. AND D.C. VOLTAGES GREATER THAN 1000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 62231-1:2016 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH AC VOLTAGES GREATER THAN 1000 V UP TO 245 KV - PART 1: DIMENSIONAL, MECHANICAL AND ELECTRICAL CHARACTERISTICS
CEI EN 62772 : 1ED 2017 COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGE GREATER THAN 1000 V AND D.C. VOLTAGE GREATER THAN 1500 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
IEC TS 63014-1:2018 High voltage direct current (HVDC) power transmission - System requirements for DC-side equipment - Part 1: Using line-commutated converters
IEEE 1898-2016 IEEE Standard for High-Voltage Direct-Current (HVDC) Composite Post Insulators
UNE-EN 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
BS EN 62271-207:2012 High-voltage switchgear and controlgear Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
BS EN 62772:2016 Composite hollow core station post insulators for substations with a.c. voltage greater than 1 000 V and d.c. voltage greater than 1 500 V. Definitions, test methods and acceptance criteria
NF EN 62772 : 2016 COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGE GREATER THAN 1000 V AND D.C. VOLTAGE GREATER THAN 1500 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
09/30204441 DC : 0 BS EN 62554 - MEASUREMENT OF MERCURY LEVEL IN FLUORESCENT LAMPS
I.S. EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012 (EQV))
I.S. EN 62772:2016 COMPOSITE HOLLOW CORE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGE GREATER THAN 1000 V AND D.C. VOLTAGE GREATER THAN 1500 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
IEC TS 62896:2015 Hybrid insulators for a.c. and d.c. for high-voltage applications - Definitions, test methods and acceptance criteria
PD IEC/TS 61463:2016 Bushings. Seismic qualification
IEC TS 61463:2016 Bushings - Seismic qualification
BS EN 60505:2011 Evaluation and qualification of electrical insulation systems
PD IEC/TS 62896:2015 Hybrid insulators for a.c. and d.c. high-voltage applications. Definitions, test methods and acceptance criteria
UNE-EN 62231-1:2016 Composite station post insulators for substations with ac voltages greater than 1 000 V UP TO 245 kV - Part 1: Dimensional, mechanical and electrical characteristics
EN 62231-1:2016 Composite station post insulators for substations with AC voltages greater than 1 000 V up to 245 kV - Part 1: Dimensional, mechanical and electrical characteristics
CEI EN 60505 : 2012 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS
IEC 62772:2016 Composite hollow core station post insulators for substations with a.c. voltage greater than 1 000 V and d.c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria
IEC 60505:2011 Evaluation and qualification of electrical insulation systems
BS EN 62231-1:2016 Composite station post insulators for substations with AC voltages greater than 1 000 V up to 245 kV Dimensional, mechanical and electrical characteristics
11/30252704 DC : 0 BS EN 62231-1 - COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH AC VOLTAGES GREATER THAN 1000 V UP TO 245 KV - PART 1: DIMENSIONAL, MECHANICAL AND ELECTRICAL CHARACTERISTICS
IEC 62231-1:2015 Composite station post insulators for substations with AC voltages greater than 1 000 V up to 245 kV - Part 1: Dimensional, mechanical and electrical characteristics
IEC 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012)

IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
IEC TS 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations
IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
ISO 1101:2017 Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out
ISO 3452:1984 Non-destructive testing — Penetrant inspection — General principles
IEC 61952:2008 Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
IEC TS 61245:2015 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.