IEC 62209-2:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
05-27-2019
03-30-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Measurement system specifications
6 Protocol for SAR evaluation
7 Uncertainty estimation
8 Measurement report
Annex A (informative) - Phantom rationale
Annex B (normative) - SAR measurement system verification
Annex C (informative) - Fast SAR testing
Annex D (informative) - Standard sources and phantoms for
system validation
Annex E (informative) - Example recipes for phantom
tissue-equivalent liquids
Annex F (normative) - SAR correction for deviations of
complex permittivity from targets
Annex G (informative) - Hands-free kit testing
Annex H (informative) - Skin enhancement factor
Annex I (informative) - Tissue-equivalent liquid dielectric
property measurements and measurement
uncertainty estimation
Annex J (informative) - Testing compliance for the exposure
of the hand
Annex K (informative) - Test reduction
Annex L (normative) - Power scaling procedure
Annex M (informative) - Rationale for probe parameters
Bibliography
IEC 62209-2:2010 is applicable to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments. For transmitters used in close proximity to the human ear, the procedures of IEC 62209-1:2005 are applicable. IEC 62209-2:2010 is applicable for radio frequency exposure in the frequency range of 30 MHz to 6 GHz, and may be used to measure simultaneous exposures from multiple radio sources used in close proximity to human body. Definitions and evaluation procedures are provided for the following general categories of device types:
- body-mounted,
- body-supported,
- desktop,
- front-of-face,
- hand-held,
- laptop,
- limb-mounted,
- multi-band,
- push-to-talk,
- clothing-integrated. The types of devices considered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers. IEC 62209-2:2010 gives guidelines for a reproducible and conservative measurement methodology for determining the compliance of wireless devices with the SAR limits. The contents of the corrigendum of June 2010 have been included in this copy.
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
239
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 62209-2 : 2010 | Identical |
NBN EN 62209-2 : 2010 | Identical |
NEN EN IEC 62209-2 : 2010 | Identical |
I.S. EN 62209-2:2010 | Identical |
PN EN 62209-2 : 2010 | Identical |
VDE 0848-209-2 : 2011 | Identical |
DIN EN 62209-2 : 2011 | Identical |
UNE-EN 62209-2:2010 | Identical |
BS EN 62209-2:2010 | Identical |
CEI EN 62209-2 : 2013 | Identical |
EN 62209-2:2010 | Identical |
PNE-FprEN 62209-2 | Identical |
EN 50527-2-1:2016 | Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-1: Specific assessment for workers with cardiac pacemakers |
13/30280457 DC : 0 | BS EN 62493 - ASSESSMENT OF LIGHTING EQUIPMENT RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS |
I.S. EN 62232:2017 | DETERMINATION OF RF FIELD STRENGTH, POWER DENSITY AND SAR IN THE VICINITY OF RADIOCOMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE |
NF EN 62493 : 2015 | ASSESSMENT OF LIGHTING EQUIPMENT RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELD |
17/30359914 DC : 0 | BS EN 50527-2-2 - PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIOVERTER DEFIBRILLATORS (ICDS) |
17/30355634 DC : 0 | BS EN 62311 ED.2.0 - ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ) |
EN 62232:2017 | Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
CSA ISO/IEC TR 20017:14 (R2019) | Information technology - Radio frequency identification for item management - Electromagnetic interference impact of ISO/IEC 18000 interrogator emitters on implantable pacemakers and implantable cardioverter defibrillators (Adopted ISO/IEC TR 20017:2011, first edition, 2011-12-15) |
EN 62369-1:2009 | Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz - Part 1: Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems |
EN 62493:2015 | Assessment of lighting equipment related to human exposure to electromagnetic fields |
I.S. EN 50566:2017 | PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF WIRELESS COMMUNICATION DEVICES WITH THE BASIC RESTRICTIONS AND EXPOSURE LIMIT VALUES RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE FROM 30 MHZ TO 6 GHZ: HAND-HELD AND BODY MOUNTED DEVICES IN CLOSE PROXIMITY TO THE HUMAN BODY |
IEC TS 62997:2017 | Industrial electroheating and electromagnetic processing equipment - Evaluation of hazards caused by magnetic nearfields from 1 Hz to 6 MHz |
PD IEC/PAS 63083:2017 | Specific absorption rate (SAR) measurement procedure for long term evolution (LTE) devices |
13/30276624 DC : 0 | BS EN 62704-1 ED 1.0 - RECOMMENDED PRACTICE FOR DETERMINING THE PEAK SPATIAL-AVERAGE SPECIFIC ABSORPTION RATE (SAR) IN THE HUMAN BODY FROM WIRELESS COMMUNICATIONS DEVICES; 30 MHZ -6 GHZ - PART 1: GENERAL REQUIREMENTS FOR USING THE FINITE DIFFERENCE TIME DOMAIN (FDTD) METHOD SAR CALCULATIONS |
PREN 50527-2-2 : DRAFT 2017 | PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIOVERTER DEFIBRILLATORS (ICDS) |
CEI EN 62369-1 : 2013 | EVALUATION OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FROM SHORT RANGE DEVICES (SRDS) IN VARIOUS APPLICATIONS OVER THE FREQUENCY RANGE 0 GHZ TO 300 GHZ - PART 1: FIELDS PRODUCED BY DEVICES USED FOR ELECTRONIC ARTICLE SURVEILLANCE, RADIO FREQUENCY IDENTIFICATION AND SIMILAR SYSTEMS |
ISO/IEC TR 20017:2011 | Information technology Radio frequency identification for item management Electromagnetic interference impact of ISO/IEC 18000 interrogator emitters on implantable pacemakers and implantable cardioverter defibrillators |
CEI EN 62232 : 1ED 2018 | DETERMINATION OF RF FIELD STRENGTH, POWER DENSITY AND SAR IN THE VICINITY OF RADIOCOMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE |
IEC 62369-1:2008 | Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz - Part 1: Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems |
IEC 62493:2015 | Assessment of lighting equipment related to human exposure to electromagnetic fields |
EN 50527-2-2:2018 | Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 2-2: Specific assessment for workers with cardioverter defibrillators (ICDs) |
CEI EN 50566 : 2014 | PRODUCT STANDARD TO DEMONSTRATE COMPLIANCE OF RADIO FREQUENCY FIELDS FROM HANDHELD AND BODY-MOUNTED WIRELESS COMMUNICATION DEVICES USED BY THE GENERAL PUBLIC (30 MHZ - 6 GHZ) |
PREN 50566 : DRAFT 2017 | PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF WIRELESS COMMUNICATION DEVICES WITH THE BASIC RESTRICTIONS AND EXPOSURE LIMIT VALUES RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE FROM 30 MHZ TO 6 GHZ: HAND-HELD AND BODY MOUNTED DEVICES IN CLOSE PROXIMITY TO THE HUMAN BODY |
BS EN 62493:2015 | Assessment of lighting equipment related to human exposure to electromagnetic field |
08/30136850 DC : DRAFT JAN 2008 | BS EN 62232 - DETERMINATION OF RF FIELDS IN THE VICINITY OF MOBILE COMMUNICATION BASE STATIONS FOR THE PURPOSE OF EVALUATING HUMAN EXPOSURE |
BS EN 62369-1:2009 | Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems |
13/30276628 DC : 0 | BS EN 62704-3 ED 1.0 - DETERMINING THE PEAK SPATIAL-AVERAGE SPECIFIC ABSORPTION RATE (SAR) IN THE HUMAN BODY FROM WIRELESS COMMUNICATIONS DEVICES; 30 MHZ - 6 GHZ - PART 3: SPECIFIC REQUIREMENTS FOR USING THE FINITE-DIFFERENCE TIME-DOMAIN (FDTD) METHOD FOR SAR CALCULATIONS OF MOBILE PHONES |
UNE-EN 62369-1:2011 | Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz -- Part 1: Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems |
IEC PAS 63083:2017 | Specific absorption rate (SAR) measurement procedure for long term evolution (LTE) devices |
12/30239867 DC : 0 | BS EN 62368-1 - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
PD IEC/TS 62997:2017 | Industrial electroheating and electromagnetic processing equipment. Evaluation of hazards caused by magnetic nearfields from 1 Hz to 6 MHz |
17/30353676 DC : 0 | BS EN 50566 - PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF WIRELESS COMMUNICATION DEVICES WITH THE BASIC RESTRICTIONS AND EXPOSURE LIMIT VALUES RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS IN THE FREQUENCY RANGE FROM 30 MHZ TO 6 GHZ: HAND-HELD AND BODY MOUNTED DEVICES IN CLOSE PROXIMITY TO THE HUMAN BODY |
BS EN 62232:2017 | Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure (IEC 62232:2017) |
12/30258453 DC : 0 | BS EN 62368-1 AMD - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
IEC/IEEE 62704-1:2017 | Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 1: General requirements for using the finite difference time-domain (FDTD) method for SAR calculations |
UNE-EN 62493:2015 | Assessment of lighting equipment related to human exposure to electromagnetic Field |
I.S. EN 50527-2-2:2018 | PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIOVERTER DEFIBRILLATORS (ICDS) |
IEC TR 62905:2018 | Exposure assessment methods for wireless power transfer systems |
I.S. EN 50527-2-1:2016 | PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIAC PACEMAKERS |
IEC 62232:2017 | Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
UNE-EN 50566:2013 | Product standard to demonstrate compliance of radio frequency fields from handheld and body-mounted wireless communication devices used by the general public (30 MHz - 6 GHz) |
ECMA/TR 97 : 1ED 2009 | GUIDE FOR ASSESSMENT OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FROM MULTIMEDIA PRODUCTS IN ACCORDANCE WITH IEC/EN 62311 |
BS IEC 62232:2011 | Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure |
I.S. EN 62369-1:2009 | EVALUATION OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FROM SHORT RANGE DEVICES (SRDS) IN VARIOUS APPLICATIONS OVER THE FREQUENCY RANGE 0 GHZ TO 300 GHZ - PART 1: FIELDS PRODUCED BY DEVICES USED FOR ELECTRONIC ARTICLE SURVEILLANCE, RADIO FREQUENCY IDENTIFICATION AND SIMILAR SYSTEMS |
09/30207082 DC : 0 | BS EN 50383:2002/FPRAA - BASIC STANDARD FOR THE CALCULATION AND MEASUREMENT OF ELECTROMAGNETIC FIELD STRENGTH AND SAR RELATED TO HUMAN EXPOSURE FROM RADIO BASE STATIONS AND FIXED TERMINAL STATIONS FOR WIRELESS TELECOMMUNICATION SYSTEMS (110 MHZ - 40 GHZ) |
PD IEC/TR 62630:2010 | Guidance for evaluating exposure from multiple electromagnetic sources |
IEC TR 62630:2010 | Guidance for evaluating exposure from multiple electromagnetic sources |
IEC PAS 63151:2018 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz) |
IEEE 1528-2013 REDLINE | IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques |
I.S. EN 62493:2015 | ASSESSMENT OF LIGHTING EQUIPMENT RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS |
IEC/IEEE 62704-3:2017 | Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 3: Specific requirements for using the finite difference time domain (FDTD) method for SAR calculations of mobile phones |
EN 50566:2017 | Product standard to demonstrate the compliance of wireless communication devices with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 30 MHz to 6 GHz: hand-held and body mounted devices in close proximity to the human body |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEEE 1528-2013 REDLINE | IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques |
SA TR IEC 63170:2020 | Measurement procedure for the evaluation of power density related to human exposure to radio frequency fields from wireless communication devices operating between 6 GHz and 100 GHz |
IEC 62311:2007 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
AS IEC 62209.3:2020 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz) |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.