• There are no items in your cart

IEC 61788-1:2006

Current

Current

The latest, up-to-date edition.

Superconductivity - Part 1: Critical current measurement - DC critical current of Nb-Ti composite superconductors

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

11-21-2006

US$220.00
Excluding Tax where applicable

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Requirements
6 Apparatus
   6.1 Measurement mandrel material
   6.2 Mandrel construction
7 Specimen preparation
   7.1 Specimen bonding
   7.2 Specimen mounting
8 Measurement procedure
9 Uncertainty of the test method
   9.1 Critical current
   9.2 Temperature
   9.3 Magnetic field
   9.4 Specimen and mandrel support structure
   9.5 Specimen protection
10 Calculation of results
   10.1 Critical current criteria
   10.2 n-value (optional calculation, refer to A.7.2)
11 Test report
   11.1 Identification of test specimen
   11.2 Report of I[c] values
   11.3 Report of test conditions
Annex A (informative) Additional information relating to
                      the standard
Annex B (informative) Self-field effect
Annex C (normative) Test method for Cu/Cu-Ni/Nb-Ti composite
                    superconductors
Annex D (informative) Guidance for estimating winding tensile
                      force
Bibliography

This part of IEC 61788 covers a test method for the determination of the d.c. critical current of either Cu/Nb-Ti composite superconductors that have a copper/superconductor ratio larger than 1 or Cu/Cu-Ni/Nb-Ti wires that have a copper/superconductor ratio larger than 0,9 and a copper alloy (Cu-Ni)/superconductor ratio larger than 0,2, where the diameter of Nb-Ti superconducting filaments is larger than 1 micrometre. The changes for the Cu/Cu-Ni/Nb-Ti are described in Annex C. The Cu-Ni uses all of the main part of the standard with the exceptions listed in Annex C that replace (and in some cases are counter to) some of the steps inthe main text.This method is intended for use with superconductors that have critical currents less than 1 000 A and n-values larger than 12, under standard test conditions and at magnetic fields less than or equal to 0,7 of the upper critical magnetic field. The test specimen is immersed in a liquid helium bath at a known temperature during testing. The test conductor has a monolithic structure with a round or rectangular cross-sectional area that is less than 2 mm2. The specimen geometry used in this test method is an inductively coiled specimen. Deviations from this test method that are allowed for routine tests and other specific restrictions are given in this standard.Test conductors with critical currents above 1 000 A or cross-sectional areas greater than 2 mm2 could be measured with the present method with an anticipated increase in uncertainty and a more significant self-field effect (see Annex B). Other, more specialized, specimen test geometries may be more appropriate for larger conductor testing which have been omitted from this present standard for simplicity and to retain a lower uncertainty. The test method given in this standard is expected to apply to other superconducting composite wires after some appropriate modifications.

Committee
TC 90
DevelopmentNote
Stability Date: 2019. (09/2017)
DocumentType
Standard
Pages
57
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
NF EN 61788-1 : 2007 Identical
NEN EN IEC 61788-1 : 2007 Identical
PN EN 61788-1 : 2007 Identical
VDE 0390-1 : 2007 Identical
BS EN 61788-1:2007 Identical
DIN EN 61788-1 : 2007 Identical
CEI EN 61788-1 : 2007 Identical
UNE-EN 61788-1:2007 Identical
PNE-prEN 61788-1 Identical
EN 61788-1:2007 Identical
UNE-EN 61788-1:1999 Identical
I.S. EN 61788-1:2007 Identical

IEC 61788-21:2015 Superconductivity - Part 21: Superconducting wires - Test methods for practical superconducting wires - General characteristics and guidance
EN 61788-8:2010 Superconductivity - Part 8: AC loss measurements - Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method
BS EN 61788-21:2015 Superconductivity Superconducting wires. Test methods for practical superconducting wires. General characteristics and guidance
CEI EN 61788-2 : 2007 SUPERCONDUCTIVITY - PART 2: CRITICAL CURRENT MEASUREMENT - DC CRITICAL CURRENT OF NB3SN COMPOSITE SUPERCONDUCTORS
BS EN 61788-8:2003 Superconductivity AC loss measurements. Total AC loss measurement of Cu/Nb-Ti composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method
BS EN 61788-2:2007 Superconductivity Critical current measurement. D.C. critical current of Nb<sub>3</sub>Sn composite superconductors
CEI EN 61788-8 : 2011 SUPERCONDUCTIVITY - PART 8: AC LOSS MEASUREMENTS - TOTAL AC LOSS MEASUREMENT OF ROUND SUPERCONDUCTING WIRES EXPOSED TO A TRANSVERSE ALTERNATING MAGNETIC FIELD AT LIQUID HELIUM TEMPERATURE BY A PICKUP COIL METHOD
I.S. EN 61788-8:2010 SUPERCONDUCTIVITY - PART 8: AC LOSS MEASUREMENTS - TOTAL AC LOSS MEASUREMENT OF ROUND SUPERCONDUCTING WIRES EXPOSED TO A TRANSVERSE ALTERNATING MAGNETIC FIELD AT LIQUID HELIUM TEMPERATURE BY A PICKUP COIL METHOD
IEC TR 61788-20:2014 Superconductivity - Part 20: Superconducting wires - Categories of practical superconducting wires - General characteristics and guidance
I.S. EN 61788-2:2007 SUPERCONDUCTIVITY - PART 2: CRITICAL CURRENT MEASUREMENT - DC CRITICAL CURRENT OF NB[3]SN COMPOSITE SUPERCONDUCTORS
IEC 61788-2:2006 Superconductivity - Part 2: Critical current measurement - DC critical current of Nb3Sn composite superconductors
PD IEC/TR 61788-20:2014 Superconductivity Superconducting wires. Categories of practical superconducting wires. General characteristics and guidance
I.S. EN 61788-21:2015 SUPERCONDUCTIVITY - PART 21: SUPERCONDUCTING WIRES - TEST METHODS FOR PRACTICAL SUPERCONDUCTING WIRES - GENERAL CHARACTERISTICS AND GUIDANCE
IEC 61788-8:2010 Superconductivity - Part 8: AC loss measurements - Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method
EN 61788-2:2007 Superconductivity - Part 2: Critical current measurement - DC critical current of Nb3Sn composite superconductors
EN 61788-21:2015 Superconductivity - Part 21: Superconducting wires - Test methods for practical superconducting wires - General characteristics and guidance

IEC 60050-815:2015 International Electrotechnical Vocabulary (IEV) - Part 815: Superconductivity
IEC 60050-121:1998 International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism
IEC 61788-5:2013 Superconductivity - Part 5: Matrix to superconductor volume ratio measurement - Copper to superconductor volume ratio of Cu/Nb-Ti composite superconducting wires

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.