IEC 61558-2-15:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for isolating transformers for the supply of medical locations
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
05-02-2022
English - French, Spanish, Castilian
11-22-2011
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and other information
9 Protection against electric shock
10 Change of input voltage setting
11 Output voltage and output current under load
12 No-load output voltage
13 Short-circuit voltage and inrush currents
14 Heating
15 Short-circuit and overload protection
16 Mechanical strength
17 Protection against harmful ingress of dust, solid
objects and moisture
18 Insulation resistance, dielectric strength and leakage
current
19 Construction
20 Components
21 Internal wiring
22 Supply connection and other external flexible cables
or cords
23 Terminals for external conductors
24 Provisions for protective earthing
25 Screws and connections
26 Creepage distances, clearances and distances through
insulation
27 Resistance to heat, fire and tracking
28 Resistance to rusting
Annexes
Annex H - Electronic circuits
Annex L - Routine tests (production tests)
Bibliography
Index of defined terms
IEC 61558-2-15:2011 deals with safety aspects of isolating transformers for the supply of medical locations. This second edition cancels and replaces the first edition published in 1999. It constitutes a technical revision. The main changes consist of updating this part in accordance with IEC 61558-1:2005. This part has the status of a group safety publication in accordance with IEC Guide 104:2010. The preparation of safety publications and the use of basic safety publications and group safety publications. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months from the date of publication.
This publication is to be read in conjunction with IEC 61558-1:2005.
Committee |
TC 96
|
DevelopmentNote |
Supersedes IEC 60742 (07/2004) Stability Date: 2015. (10/2012)
|
DocumentType |
Standard
|
Pages |
37
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NBN EN 61558 2-15 : 2012 | Identical |
NEN EN IEC 61558-2-15 : 2012 | Identical |
I.S. EN 61558-2-15:2012 | Identical |
PN EN 61558-2-15 : 2012 | Identical |
VDE 0570-2-15 : 2012 | Identical |
DIN EN 61558-2-15 : 2012 | Identical |
BS EN 61558-2-15:2012 | Identical |
UNE-EN 61558-2-15:2012 | Identical |
CEI EN 61558-2-15 : 2013 | Identical |
EN 61558-2-15:2012 | Identical |
SN EN 61558-2-15 : 2001 | Identical |
NF EN 61558-2-15 : 2012 | Identical |
IEC TR 62348:2012 | Assessment of the impact of the most significant changes in Amendment 1 to IEC 60601-1:2005 and mapping of the clauses of IEC 60601-1:2005 to the previous edition |
IEC 60364-7-710:2002 | Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations |
UNE-HD 60364-4-444:2013 | Low-voltage electrical installations -- Part 4-444: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
ANSI/AAMI/IEC TIR62348:2012 | ASSESSMENT OF THE IMPACT OF THE MOST SIGNIFICANT CHANGES IN AMENDMENT 1 TO IEC 60601-1:2005 AND MAPPING OF THE CLAUSES OF IEC 60601-1:2005 TO THE PREVIOUS EDITION |
UNE-HD 60364-7-710:2014 | Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations |
I.S. HD 60364-4-444:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
IEC 60364-4-44:2007+AMD1:2015+AMD2:2018 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
I.S. HD 60364-7-710:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-710: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MEDICAL LOCATIONS (IEC 60364-7-710:2002 (MOD)) |
S.R. HD 60364-4-443:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-44: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES - CLAUSE 443: PROTECTION AGAINST TRANSIENT OVERVOLTAGES OF ATMOSPHERIC ORIGIN OR DUE TO SWITCHING |
HD 60364-7-710:2012/AC:2013 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-710: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MEDICAL LOCATIONS |
HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
HD 60364-4-444:2010/AC:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
HD 60364-4-442:2012 | Low-voltage electrical installations - Part 4-442: Protection for safety - Protection of low-voltage installations against temporary overvoltages due to earth faults in the high-voltage system and due to faults in the low voltage system |
IEC 60364-7-710:2002 | Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.